Introduction ................................................................................................... 3
Product Quality.............................................................................................. 3
Safety ............................................................................................................ 3
Features......................................................................................................... 4
Included......................................................................................................... 4
Specications.............................................................................................4-5
Instrument Description.................................................................................. 6
Display Description ....................................................................................... 7
Distance & Spot Size..................................................................................... 8
Operating Instructions..............................................................................9-13
Power ON and OFF .................................................................................. 9
Manual Measurement............................................................................... 9
Continuous Temperature Measurement (Trigger Lock) ............................ 9
Maximum, Minimum, Average and Differential Functions ...................... 10
Turning Laser On/Off .............................................................................. 10
Setting the High Temperature Alarm ...................................................... 11
Setting the Low Temperature Alarm....................................................... 11
Adjusting Emissivity................................................................................ 12
Switching the Unit of Measure (°F/°C).................................................... 12
Audible Alarm Setting............................................................................. 13
Trigger Lock Setup ................................................................................. 13
Turning High and Low Alarms ON/OFF............................................. 13-14
Battery Replacement................................................................................... 15
Applications................................................................................................. 15
Appendix: Emissivity Chart ....................................................................16-18
Fault Diagnostics......................................................................................... 18
Product Care ............................................................................................... 18
Product Warranty ........................................................................................ 19
Product Disposal and Recycling ................................................................. 19
Product Support.......................................................................................... 19
REED Instruments

3
Introduction
Thank you for purchasing your REED R2330 Infrared Thermometer. Please
read the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
• Never attempt to repair or modify your
instrument. Dismantling your product,
other than for the purpose of replacing
batteries, may cause damage that will
not be covered under the manufacturer's
warranty. Servicing should only be
provided by an authorized service center.
• Use extreme caution when the laser beam
is turned on.
• Do not let the beam enter your eye, another person's eye or the eye of
an animal.
• Be careful not to point the beam off a reective surface and strike your eye.
• Do not allow the laser light beam to impinge on any gas which can explode.
REED Instruments

4
Features
• Built-in laser pointer identies target area
• User selectable °F or °C
• 50:1 Distance to Spot size ratio
• Bright color display (EBTN)
• Digitally adjustable emissivity
• Max, Min, Average and Differential readings
• Audible (beep) and visual (tri-color LED) user adjustable alarms
• Internal memory stores up to 5 pre-set high & low alarms and 5
emissivity settings
• Trigger lock and tripod mount for continuous monitoring
• Low battery indication and auto shut off
Included
• Carrying Case
• Battery
Specifications
Temperature Range: -26 to 2282°F (-32 to 1250°C)
Accuracy: Basic: ±1.8% of reading or 3.6°F (1.8°C)
Detailed: ≥0°C: ±1.8°C or ±1.8% of reading
whichever is greater
<0°C: ±(1.8°C+0.1°C/°C)
≥32°F: ±3.6°F or ±1.8% of reading,
whichever is greater, <32°F: ±(3.6°F+0.1°F/°F)
Resolution: 0.1°F (0.1°C)
Optical Resolution (D:S): 50:1
Laser Optimization Distance:
5.2' (1.6m)
Repeatability: 0.8°C or 0.8%, whichever is greater
(1.8°F or 0.8%, whichever is greater)
continued...
REED Instruments

5
Dual Laser: Yes
Spectral Response: 8 to 14µm
Emissivity: 0.1 to 1.0 (Adjustable)
Response Time: 250ms
Backlit Display: Yes (Color EBTN)
Display Hold: Yes
High/Low Alarms: Yes (audible and visual)
Alarm Indicators: LED (High: Red, Low: Blue)
Max/Min: Yes
Average and Differential: Yes
F/C Switchable: Yes
Trigger Lock: Yes
Internal Memory: Yes
Tripod Mountable: Yes
Laser Class: Class II
Low Battery Indicator: Yes
Power Supply: 9V Battery
Battery Life: Approx. 7 hours
(with continuous use, backlight on)
Product Certications: CE, RoHS
Operating Temperature: 32 to 122°F (0 to 50°C)
Storage Temperature: -4 to 140°F (-20 to 60°C)
Operating Humidity Range: 10 to 90%
Maximum Operating Altitude: 6561' (2000m)
Maximum Storage Altitude: 39370' (12000m)
Dimensions: 7 x 4.98 x 2" (179 × 126.5 × 53mm)
Weight: 10.95oz (310g)
REED Instruments

6
Instrument Description
3
4
5
6
7
8
9
10
-26~1472°F / -32~800°C
D:S=30:1
1.2@36
0.9@12
2.5@60
30@900
24@300
62@1500
R2320
Professional
Infrared Thermometer
www.REEDINSTRUMENTS.com
1. Dual Laser Pointer Beams
2. IR Sensor
3. Trigger
4. Battery Cover
5. Tripod Mount
6. LCD Display
7. Mode Button/Down Arrow
8. Set Button
9. High/Low Alarm Button/
Up Arrow
10. Laser ON/OFF Button
REED Instruments

7
Display Description
Temperature Measurement Trigger Lock
Audible Alarm Indicator
Temperature Measurement Alarm Indicator
Low Battery
Temperature Measurement Active
Measurement Data Hold
Unit of Measurement
Temperature Measurement Value
Temperature Measurement Value from Selected Mode
Emissivity
Laser On
Mode
K
K
REED Instruments

8
Distance & Spot Size
4
8
88 7
REED Instruments

9
Operating Instructions
Power ON and OFF
1. Gently pull the trigger to turn the thermometer on. The LCD
display and the backlight will turn on.
2. The thermometer will automatically shut off after 15 seconds
of inactivity.
Manual Measurement
1. Pull and hold the trigger after aiming at the target. The icon
will ash, indicating that the target temperature is being measured.
2. When the trigger is released, the icon will disappear and the
icon will appear indicating that measurement has stopped
and the last measured temperature will remain on-screen until
another measurement is taken or the unit turns off.
Continuous Temperature Measurement (Trigger Lock)
T
he instrument allows for a continuous temperature measurement time to
be set from 1 minute to 4 hours. Refer to Trigger Lock Setup for details.
Note: This function is applicable for processes that require regular
monitoring of temperature.
1. Once the trigger lock function is enabled, the icon will appear on
the display and the SCAN icon will ash when the trigger is pressed.
2. Pull the trigger again to stop measuring and both the and SCAN
icons will disappear and the HOLD icon will appear. The thermometer
will now hold the last measured value until the unit turns off after 15
seconds of inactivity or until testing is resumed.
3. When the continuous temperature measurement time is reached, the
thermometer will automatically power off and save the last measured
value. You can view the last measured value by pulling the trigger.
Note: The last measured value is cleared when a new test scan is started.
continued...
REED Instruments

10
Maximum, Minimum, Average and Differential Functions
Press the MODE button to toggle between MAX/MIN/AVG/DIF modes.
The temperature value of corresponding modes are shown in the
secondary display area.
Turning Laser On/Off
Press the button to turn the laser indicator function ON and OFF.
When it is turned on, the laser indicator will be displayed on the LCD,
while the red laser beam will indicate the position you are measuring
during testing.
continued...
REED Instruments
Table des matières
Autres manuels Reed Instruments Thermomètre

Reed Instruments
Reed Instruments R2340 Manuel utilisateur

Reed Instruments
Reed Instruments SMART Series Manuel utilisateur

Reed Instruments
Reed Instruments R2450SD Manuel utilisateur

Reed Instruments
Reed Instruments R2000 Manuel utilisateur

Reed Instruments
Reed Instruments R2330-NIST Manuel utilisateur

Reed Instruments
Reed Instruments Smart Series Manuel utilisateur

Reed Instruments
Reed Instruments FS-200 Manuel utilisateur

Reed Instruments
Reed Instruments R2320 Manuel utilisateur

Reed Instruments
Reed Instruments C-370 Manuel utilisateur

Reed Instruments
Reed Instruments R2020 Manuel utilisateur