Puretec SOL-E3 Series Manuel utilisateur

User Guide
Volumetric Water Softening Appliance
SOL-E3 Commercial Series
For correct operation & installation, it is essential to observe these instructions.OCT2021
WMTS103:2016
Licence No. WM 74593
Australian Certication
Services
DO NOT
DO NOT USE
LIQUID SEALANTS.
SURGE PROTECTION
REQUIRED /
NO EXTENSION CORDS.
SURGE PROTECTION
REQUIRED /
NO EXTENSION CORDS.

2 Installation & Operation Manual Copyright © Puretec Pty Ltd 2021
What's Inside
What's Inside
Puretec Customer Service ............................................................................................................................3
Installation Record ............................................................................................................................................4
Before Installation..............................................................................................................................................5
Specications........................................................................................................................................................7
Model Information..............................................................................................................................................8
Exploded Diagram...........................................................................................................................................10
Valve Diagram Identication.....................................................................................................................11
Installation Procedure...................................................................................................................................12
Programming .....................................................................................................................................................17
Start-Up ................................................................................................................................................................23
Regeneration......................................................................................................................................................23
Replenishment of Salt Supply ..................................................................................................................24
Type of Salt to Use.........................................................................................................................................24
Brine Tank Clean-Out (Yearly)...................................................................................................................24
Media Replacement........................................................................................................................................24
Bypass Valve Operation - optional accessory .................................................................................25
Troubleshooting Guide ..................................................................................................................................26
Warranty...............................................................................................................................................................30

3Copyright © Puretec Pty Ltd 2021 SOL-E3 Commercial Series User Guide
Puretec Customer Service
Puretec Customer Service
Thank you for purchasing a Puretec Sorol Volumetric Water Soening System. Your
system is a proven performer manufactured from only quality materials and components.
It will give years of reliability and trouble free operation if maintained properly.
This user guide is designed for Puretec SOL-E3 Water Treatment Systems. Be careful to
ensure the information and illustration is applicable to your particular unit.
Caution: Do not use with water that is microbiologically unsafe or without
adequate disinfection before or aer the system.
The systems are designed for metropolitan supply water but can be used in other
situations. For other types of water supply, please contact your local Puretec dealer.
Puretec Water Soeners are designed to run economically for many years, dependent on
the initial installation and periodic maintenance.
Flush system for 5 minutes or more, aer any period of non-use, more than 2 weeks.
Note: For point of entry installations an approved dual check backow prevention device
must be installed.
When line pressure exceeds 500 kPa, a pressure limiting valve must be installed.
Note: Water soener salt not supplied.
Installation Note: A water lter system/tap, like any product, has a limited life and may
eventually fail. Also sometimes failure happens early due to unforeseen circumstances.
To avoid possible property damage, this product should be regularly examined for
leakage and/or deterioration and replaced when necessary. A drain pan, plumbed to an
appropriate drain or outtted with a leak detector, should be used in those applications
where any leakage could cause property damage, and/or the water supply should be
turned o if no one is home/present.
INSTALLATION SHOULD BE COMPLETED BY QUALIFIED TRADESPEOPLE. FAULTY
OPERATION DUE TO UNQUALIFIED PERSONS WILL RESULT IN VOIDED WARRANTY
COVERAGE.
Warning: Chlorine (free chlorine) tolerance is 1ppm - high chlorine levels permanently
damage the soening resin & is not covered under warranty. If chlorine exceeds this
limit, we recommend a carbon pre-lter such as the WH2 or CFS Series. Please refer to
Puretec for a specic recommendation. In any case, a carbon pre-lter is recommended
to protect against chlorine spikes & prolong the resin life.

4 Installation & Operation Manual Copyright © Puretec Pty Ltd 2021
Product Information
Model Number:
Serial / Batch Number:
Purchased from:
Date of Installation:
Installer / Plumber Details:
Regen Frequency: ________ Days
Water Analysis Information
Hardness: ___________ ppm / mg/L
Iron: ___________ ppm / mg/L
Manganese: ___________ ppm / mg/L
pH: ___________
TDS (Total Dissolved Salts): ___________ ppm / mg/L
Conductivity: ___________ EC / uS/cm
Chloride: ___________ ppm / mg/L
Sodium: ___________ ppm / mg/L
Installation Record
For future reference, ll in the following data:
Installation Record

5Copyright © Puretec Pty Ltd 2021 SOL-E3 Commercial Series User Guide
Before Installation
Professional Installation Required
• Installation requires shutting water o to home, cutting home water supply pipe
and using a welding torch to add piping and ttings. Specialised tools and skills are
required, this must be completed by a qualied tradesperson.
Make Sure Your Water Has Been Thoroughly Tested
• An analysis of your water should be made prior to the selection of your water
conditioning equipment. Your dealer will generally assist with this service for
you, and may send a sample to an independent laboratory for analysis and
recommendations. Enter your analysis information on page 4 for your permanent
record.
• Soeners are designed to reduce hardness but can handle reasonable amounts
of soluble iron if consideration is given to content when selecting model and
regeneration settings. For best results contact Puretec to discuss.
Install Water Conditioning Equipment Correctly
Select the location of your water soener with care. Various conditions which contribute
to proper location are as follows:
• Install as close as possible to a drain.
• Install in correct relationship to other water treatment equipment. Contact Puretec
for assistance.
• Install the soener in the supply line BEFORE the water heater. Temperatures above
40°C will damage the soener and void the warranty.
• DO NOT install the soener in a location where freezing temperatures occur.
Freezing may cause permanent damage and will also void the warranty.
• DO NOT install where water hammer conditions may occur without installing an
arrestor.
• Allow sucient space around the installation for easy servicing. Provide a non-
switched 240V power source for the control valve.
Before Installation

6 Installation & Operation Manual Copyright © Puretec Pty Ltd 2021
Before Installation
• The control valve, ttings and/or bypass are designed to accommodate minor plumbing
misalignment but are not designed to support the weight of a system or the plumbing.
• Do not use petroleum jelly, oils, other hydrocarbon lubricants or spray silicone anywhere.
A silicon lubricant may be used on the black o-rings but it is not necessary.
• Do not use pipe dope or other sealants on threads. Thread seal tape is the preferred
sealant but is not necessary on the nut connection or caps because of o-ring seals.
• All plumbing should be done in accordance with local plumbing codes. The pipe size for
the drain line should be a minimum of ⅝”.
• Avoid getting primer and solvent cement on lter system.
• Install grounding strap on metal pipes if required.
• Ensure the system is protected against high pressure and extreme temperatures.
• Chlorine (free chlorine) tolerance is 1ppm - high chlorine levels permanently damage
the soening resin & is not covered under warranty. If chlorine exceeds this limit, we
recommend a carbon pre-lter such as the WH2 or CFS Series. Please refer to Puretec
for a specic recommendation. In any case, a carbon pre-lter is recommended to
protect against chlorine spikes & prolong the resin life.
Things to Remember While Planning Your Installation:
• All installation procedures MUST conform to local plumbing codes.
• If lawn sprinklers, a swimming pool, or geothermal heating/cooling or water for
other devices/activities are to be treated by the Sorol system, a larger model MUST
be selected to accommodate the higher ow rate, treated water volume, plus the
backwashing requirements of the Sorol system. Contact Puretec for assistance.
WARNINGS
Note: Solder joints must be done prior to connecting to the valve ttings. Leave at least 6”
between the tting and solder joints when soldering pipes. Failure to do this could cause
heat damage to the ttings.
This should be carried out by a qualied tradesman.

7Copyright © Puretec Pty Ltd 2021 SOL-E3 Commercial Series User Guide
Specications
Specications
Pressure Min/Max 140 - 860* kPa
Operating Temperature Min/Max: 5 - 40 °C (protect from
freezing)
Electrical Connection: 240V / 50 Hz
Inlet/outlet Connection: 25 mm
Drain Connection: ⅝" Tube or ¾" BSP
Overow Connection: ⅝”
SOL-45 SOL-60
Width (mm) (W): 260 mm 300 mm
Height (mm) (H): 1570 mm 1525 mm
Maximum Salt Storage
Capacity: 75 kg 75 kg
*If pressure exceeds 500kPa an approved pressure limiting device needs to be tted.
(W)
430
900
(H)

8 Installation & Operation Manual Copyright © Puretec Pty Ltd 2021
Kit Type Part no. Description Qty
Tank Kit
(WTP2280-K)
WTD2130 Riser & Distributor, 1.05" x 72" (pre-installed) 1
WTP2280 Pressure Tank with Grey Base, 10" x 54" 1
WTV3030 Pressure Tank UV Collar Shield suits 2.5" 1
LBL-WTSHEAD Puretec Logo Label for Pressure Tank 1
Valve Kit
(WTV4200-K)
WTV4200 Valve Soener Volumetric E3 1
WTV5110 Valve Cover Almond (pre-installed) 1
WTV5135 Transformer & Lead Suits Auto Valves
(pre-connected)
1
- Drain Assembly 1
WTD1010 Top Screen (Click Lock) (pre-installed) 1
WTV5180 Spanner 1
WTV5070 Plastic Fitting Kit, 1" Elbow (set of 2)
(pre-installed)
1
Brine Kit
(WTB2200-K)
WTB2200 Brine Tank, Commercial, 15" x 17" x 33" 1
WTB4000 Brine Pickup Assembly (pre-installed) 1
WTB3200 Brine Well Caps, 3" (pre-installed) 2
WTB3000 Brine Well, 3.5" x 28" (pre-installed) 1
WTB5150 2 Pce Overow Kit (pre-installed) 1
KTU6BK Tubing, High Pressure, 3/8" Black 1m
KEC66 Elbow Connector, 3/8" Tube (pre-installed) 1
Media Kit
WTM7550-5L Multi-media High Performance Medium 5L 1
WTM4400-15L Resin Cation Soening 15L 1
WTM4400-25B Resin Cation Soening 25L Bag 1
Instruction Kit
(WTI-SOL45-E3)
LBL-METALLICBLANK Metallic Silver Model Label (60x100) 1
UG-SOL-E3-C Commercial SOL-E3 User Guide 1
WTV1500 Media Funnel 1
WTV5240 DLFC Washer, 10Lpm, 3/4" 1
WTV5570 Injector, White 1
SOL45-E3 Model Information
System Inclusions - Kits & Components
Vessel Media Filling Order
1st 2nd
1 x WTM7550-5L 1 x WTM4400-15L & 1 x WTM4400-25B
Model Information

9Copyright © Puretec Pty Ltd 2021 SOL-E3 Commercial Series User Guide
SOL60-E3 Model Information
System Inclusions - Kits & Components
Vessel Media Filling Order
1st 2nd
1 x WTM7550-5L 2 x WTM4400-15L & 1 x WTM4400-25B
Model Information
Kit Type Part no. Description Qty
Tank Kit
(WTP2280-K)
WTD2130 Riser & Distributor, 1.05" x 72" (pre-installed) 1
WTP2360 Pressure Tank with Grey Base, 12" x 52" 1
WTV3030 Pressure Tank UV Collar Shield suits 2.5" 1
LBL-WTSHEAD Puretec Logo Label for Pressure Tank 1
Valve Kit
(WTV4200-K)
WTV4200 Valve Soener Volumetric E3 1
WTV5110 Valve Cover Almond (pre-installed) 1
WTV5135 Transformer & Lead Suits Auto Valves
(pre-connected)
1
- Drain Assembly 1
WTD1010 Top Screen (Click Lock) (pre-installed) 1
WTV5180 Spanner 1
WTV5070 Plastic Fitting Kit, 1" Elbow (set of 2)
(pre-installed)
1
Brine Kit
(WTB2200-K)
WTB2200 Brine Tank, Commercial, 15" x 17" x 33" 1
WTB4000 Brine Pickup Assembly (pre-installed) 1
WTB3200 Brine Well Caps, 3" (pre-installed) 2
WTB3000 Brine Well, 3.5" x 28" (pre-installed) 1
WTB5150 2 Pce Overow Kit (pre-installed) 1
KTU6BK Tubing, High Pressure, 3/8" Black 1m
KEC66 Elbow Connector, 3/8" Tube (pre-installed) 1
Media Kit
WTM7550-5L Multi-media High Performance Medium 5L 1
WTM4400-15L Resin Cation Soening 15L 2
WTM4400-25B Resin Cation Soening 25L Bag 1
Instruction Kit
(WTI-SOL60-E3)
LBL-METALLICBLANK Metallic Silver Model Label (60x100) 1
UG-SOL-E3-C Commercial SOL-E3 User Guide 1
WTV1500 Media Funnel 1
WTV5270 DLFC Washer, 20Lpm, 3/4" 1
WTV5580 Injector, Blue 1

10 Installation & Operation Manual Copyright © Puretec Pty Ltd 2021
Exploded Diagram
Exploded Diagram
Valve Cover (pre-installed)
Bypass Assembly
(optional -
puchased
separately)
⅜" Black Tubing
⅜" Elbow
Connector
(pre-installed)
Brine Pickup
Assembly
(pre-installed)
Brine
Tank
2pce
Overflow
(pre-installed)
Pressure
Tank
(Vessel)
Top Screen
(pre-installed)
UV Shield
Elbow
Connectors
(pre-installed)
Drain
Assembly
Valve
Transformer
(pre-connected)
Riser &
Distributor
(pre-installed)
DLFC Washer
Autres manuels pour SOL-E3 Series
1
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Puretec Distributeur d'eau

Puretec
Puretec QT18 Manuel utilisateur

Puretec
Puretec K series Manuel utilisateur

Puretec
Puretec SOL-2CI Series Manuel utilisateur

Puretec
Puretec SOL-E1 Series Manuel utilisateur

Puretec
Puretec SOL-E3 Series Manuel utilisateur

Puretec
Puretec ROS2700 Manuel utilisateur

Puretec
Puretec CO-RO3 Manuel utilisateur

Puretec
Puretec SOL-TA Series Manuel utilisateur

Puretec
Puretec Sparq S4 Manuel utilisateur

Puretec
Puretec Softrol E3 Manuel utilisateur























