MANUAL
KIT CONTROL BOX WITH GUI
▪Compact format box with easy plug and play
connection
▪Only a USB connection with the PC needed
▪Easy to integrate in existing setups
▪An additional software makes it possible to run
the Kit Encoder main functions
▪Easy way to do the calibration, preset, pulse
testing and filter setting with the Kit Encoder
▪Additional possibility to read out the
temperature and kit encoder firmware version

Manual Kit Control Box with GUI
Page 2
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
Contents
Contact..................................................................................................................................................................3
1. Electrical Connection.......................................................................................................................................... 4
1.1 Connector............................................................................................................................................................ 4
1.2 Electrical Characteristics ..................................................................................................................................... 5
2. Software ............................................................................................................................................................ 6
2.1 Installation........................................................................................................................................................... 6
2.2 Connection with the Kit Encoder......................................................................................................................... 6
2.3 Function Overview .............................................................................................................................................. 7
2.4 Start Page............................................................................................................................................................ 7
2.5 Calibration........................................................................................................................................................... 9
2.6 Preset ................................................................................................................................................................ 11
2.7 Wiegand Sensor Testing.................................................................................................................................... 13
2.8 Filter Selection................................................................................................................................................... 15
2.9 Register communication ................................................................................................................................... 16
2.10 Read Position................................................................................................................................................... 17
2.11 Update Firmware ............................................................................................................................................ 19
3. References....................................................................................................................................................... 21
4. History ............................................................................................................................................................. 21

Manual Kit Control Box with GUI
Page 3
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
Version Date: 16.08.2020
Version Number: 2.0
Authors: JSC
Reviewer: KMA, YTR
Valid for:
Kit Control Box
With software version SW V.2.0.0.
Kit encoder with BiSS C interface (type KCD-BC0xB-1617-xxxx-xxx)
Kit encoder with SSI interface (type KCD-S10xB-1617-xxxx-xxx)
User Annotation
Please note, that no responsibility is assumed by POSITAL for any consequences arising from the use of
this material. This document is not intended as an instruction manual for untrained personnel.
POSITAL welcomes all readers to send their feedback about the product and this document.
Contact
FRABA America
T +1 609 750-8705
FRABA Europe
T +49 221 96213-0
FRABA Asia
T +65 6514 8880
© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to
change without notice.

Manual Kit Control Box with GUI
Page 4
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
1. Electrical Connection
The Kit Control Box can be connected to encoders of the types:
•Kit encoder with BiSS C interface (type KCD-BC0xB-1617-xxxx-xxx)
•Kit encoder with SSI interface (type KCD-S10xB-1617-xxxx-xxx)
Please, make sure that only KIT CONTROL BOX KCB-VA produced after the 19th week of
2020 (on the product label indicated as 19/20) are connected to/used for configuration of
22mm ø Kit Encoders with type keys KCD-xx03B-xx17-xxxF-xxx.
1.1 Connector
Connector Type Encoder Kit Interface: BM04B-GHS-TBT (JST) / BM08B-NSHSS -TBT
Pin No.
Function
Remark
1 (blue)
GND
3 (grey)
UART
Rx/Tx
8 (red)
VCC
+5V
Table 1: JST connector allocation
Connector Type Control Box Interface: D-Sub 15 pin female
Pin No.
Function
Remark
11 (blue)
GND
10 (grey)
UART
Rx/Tx
15 (red)
VCC
+5V
Table 2: D-Sub 15 connector allocation

Manual Kit Control Box with GUI
Page 5
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
1.2 Electrical Characteristics
Item
No.
Parameter
Symbol
Min.
Typ.
Max
Unit
Remark
Input Voltage
4,5
5
5,5
V
via USB
Input Current
100
mA
Short circuit protection
YES
Output Voltage encoder
12
V
UART Voltage
3,3
5
5,5
V
Table 3: Kit Control Box electrical characteristics.
Figure 1: Kit Control Box Overview

Manual Kit Control Box with GUI
Page 6
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
2. Software
2.1 Installation
For the software execution the Labview Run-Time Engine 2015 SPI (32 bit) is required. For installation, use
the Kit Control Box Installer and start the “setup.exe”. It will automatically install the Labview Run-Time on
your PC. To connect with the Kit Control Box, the FTDI driver for the FT232R chip is required. The installation
of the Windows driver will start automatically after the installation of the Kit Control Box software. For other
operation systems, it can be downloaded from the FTDI Chip Homepage (Link:
http://www.ftdichip.com/Drivers/D2XX.htm). After the installation the KitControlBox.exe in the folder can be
started.
2.2 Connection with the Kit Encoder
After connecting the Kit Control Box with the kit encoder and via USB with the PC, the “Connect” button has
to be activated. After a successful connection, the green light “Device connected” will turn on and the status
display will show the actual temperature, firmware version, serial number and the content of the error and
warning register. For further information about the error and warning register value, please have a look at
the Kit Encoder manual. With the refresh button, the values will be updated. To disconnect, the “Connect”
button needs to be pressed again.
In case of connection failure, an error message will appear.
Figure 2: Status display
Figure 3: Connection Error message

Manual Kit Control Box with GUI
Page 7
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
2.3 Function Overview
The Kit Control Box software is an easy way to perform the set up of the main functions of the Kit Encoder.
•Calibration
•Preset
•Wiegand Pulse Test
•Filter Selection
•Register Communication
To run above mentioned functions, the Kit Control Box must be connected to the encoder kit.
2.4 Start Page
When the software is initialized, the start page will appear. From there you can navigate to Fraba website,
for further information materials, e.g. manualsand datasheets for Kit Control Box or Kit Encoder.
Figure 4: Start Page
2.5 Status
For reading the content of the error and warning register, go to the page “Status”. By activating the “Read
Status” button, the error and warning register will be read. The value is in hexadecimal format. “Bit 0…7” in
the error field describes possibleerrors and “Bit 0…2” in the warning field shows the warnings. The following
tables explain the meaning of the bits.

Manual Kit Control Box with GUI
Page 8
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
Error Bit
Description
0
FRAM Error
1
Multiturn Error
2
Singleturn Error
3
Temperature Sensor Fault
4
Magnetic Field too low
e.g. detect missing magnet
5
Not used
6
Not used
7
Not used
Warning Bit
Description
0
Temperature too high
Set at T >= 125°C, clear warning at T <
123°C
1
Not used
2
Not used
Figure 5: Status reading

Manual Kit Control Box with GUI
Page 9
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
2.5 Calibration
The electronic calibration of the BiSS kit encoder is required to improve the measurement accuracy of the
kit encoder after installation. The calibration of the fully mounted sensor requires rotation of the motor shaft
at constant speed of 500 rpm, where deviation of angular velocity should be less than 2 rpm. For further
information, refer to Kit Encoder Manual.
Calibration Procedure
The calibration is performed by carrying out the following sequence:
1. Initiatethe procedure with the button “Start Calibration” in the main calibration window
Figure 6: Calibration main window
2. A pop-up window will give a signal to begin the rotation of the motor in CCW direction. The motor
should be run at constant rotational speed of 500 rpm < ±2 rpm. Once established, confirm with
“OK” button.

Manual Kit Control Box with GUI
Page 10
Version: 2020-09-10
MANUAL
KIT CONTROL BOX WITH GUI
Figure 7: Start Calibration CCW direction
3. The calibration status window will appear. Please wait until the “CCW done” light turns on. The
execution will take about 3 seconds.
Figure 8: Calibration status windows
4. Run the motor in CW direction. Once motion is established, confirm with “OK” button in the pop-
up window.
Figure 9: Start Calibration CW direction
5. After CW direction calibration wass successfully finished, the “CW done” light in the status
window will turn on. In the main calibration window, the “Calibration done” light will turn on. The
calibration is now successfully completed.
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur