Getting started PiiGAB M-Bus 900S

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 2
Contents
1. DOCUMENT INFORMATION ............................................................................................ 3
1.1 VERSIONS..................................................................................................................... 3
2. REQUIREMENTS............................................................................................................... 3
2.1 OPTIONAL REQUIREMENTS............................................................................................. 3
3. INSTALLATION AND CONNECTIONS ............................................................................ 4
4. MAC-ADDRESS AND SERIAL NUMBER ........................................................................ 5
5. IP-CONFIGURATION ........................................................................................................ 5
5.1 DHCP NETWORK........................................................................................................... 5
5.2 STATIC IP ..................................................................................................................... 5
6. FIND YOUR PIIGAB M-BUS 900S ON YOUR NETWORK .............................................. 8
7. CONFIGURE THE PIIGAB M-BUS 900S.......................................................................... 9
8. PIIGAB M-BUS SETUP WIZARD –M-BUS COMMUNICATION ................................... 10
8.1 COMMUNICATION WITH THE INTERNAL METER................................................................ 11
8.2 COMMUNICATE WITH TEST AND DIAGNOSTIC ADDRESS................................................... 12
8.3 COMMUNICATE WITH THE METER’S ACTUAL PRIMARY ADDRESS ...................................... 13
8.4 IDENTIFY THE METER’S ADDRESSES IN THE PIIGAB M-BUS SETUP WIZARD.................... 14
8.5 PARTS IN THE SECONDARY ADDRESS............................................................................ 14
8.6 SECONDARY ADDRESS –IDENTIFICATION NUMBER AND WILD CARDS............................... 15
8.7 ENTIRE SECONDARY ADDRESS ..................................................................................... 15
8.8 READ M-BUS VOLTAGE AND M-BUS CURRENT............................................................... 16
9. APPENDIX ....................................................................................................................... 17
9.1 CONTACTS.................................................................................................................. 17

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 3
1. Document Information
This document will describe how to configure the PiiGAB M-Bus 900S for M-Bus
communication with one M-Bus meter using static IP or DHCP.
If you see something that is not correct in this document, that misleads you or if you are
missing something please contact us so we can improve this document continuously. See
contact information at the end of the document.
1.1 Versions
Version
Modified by
Details
1.00.00
Stefan Eriksson
Initial version
1.00.01
Stefan Eriksson
Edited distributor contact information
1.01.00
Stefan Eriksson
Updated for PiiGAB M-Bus 900S
2. Requirements
Object
Detail
One PiiGAB M-Bus 900S
For at least 5 M-Bus loads and one client
One M-Bus meter
Supporting EN13757
One power supply
24V AC/DC
A patch cable
PiiGAB M-Bus Setup Wizard
Version 3.1.0 or later
2.1 Optional requirements
Object
Detail
A local area network (LAN)
With DHCP
One network switch

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 4
3. Installation and connections
1. Install the PiiGAB M-Bus Setup Wizard.
2. Connect the PiiGAB M-Bus 900S gateway to your computer with the patch cable.
3. Connect the M-Bus meter to the PiiGAB M-Bus 900S.
4. Connect the PiiGAB M-Bus 900S gateway to a 24V AC or DC power supply.
5. Turn the power supply on.
6. Wait for the PiiGAB M-Bus 900S’s Pwr LED to go steady red.
M-Bus meters
Patch cable
Power supply
24V AC/DC
Network

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 5
4. MAC-address and serial number
On the right gable of the PiiGAB M-Bus 900S you’ll find a label containing the MAC-address
and serial number of your PiiGAB M-Bus 900S. You can use this to identify your PiiGAB M-
Bus 900S with the PiiGAB M-Bus Setup Wizard.
Object
Starts with
MAC-address
E8-99-5A
Serial number
167#####
5. IP-configuration
You can either connect your PiiGAB M-Bus 900S gateway to a static or DHCP network. The
most common IP-configuration of the PiiGAB M-Bus 900S gateway is for static IP-address.
The gateway is by default set to DHCP when delivered.
5.1 DHCP network
If you have a network with DHCP you can connect your PiiGAB M-Bus 900S gateway to it
and the gateway will receive the IP-configuration automatically.
5.2 Static IP
If you don’t have a network with DHCP you must set your PiiGAB M-Bus 900S gateway to a
static IP-address.
Note: If you have an old computer you might need a network switch between your computer
and the PiiGAB M-Bus 900S gateway.
1. Set your computer to a static IP-address. For instance:
IP-address: 192.168.10.1.
Network mask: 255.255.255.0.
Gateway: 192.168.10.254.
2. Start the PiiGAB M-Bus Setup Wizard and go to the main menu.
3. Select Change gateway IP-settings.
4. Press Next to continue.

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 6
5. Select Setup IP using network (UDP broadcast).
6. In the MAC-address field specify the PiiGAB M-Bus 900S gateway’s MAC-address.
7. Press Next to continue.
8. Select Use the following IP-address.
9. Specify the IP-configuration. The PiiGAB M-Bus 900S gateway should match your
computer’s IP-address.
10. Press Next to continue.

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 7
11. Press Apply to set the IP-configuration.
12. Wait for the PiiGAB M-Bus 900S gateway to reboot.
Note: PiiGAB M-Bus Setup Wizard may signal that it failed to set the MAC-address. Please
ignore this warning. The IP-address should be set anyway.
13. Press Back three times to return to the main menu.

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 8
6. Find your PiiGAB M-Bus 900S on your network
You can use the PiiGAB M-Bus Setup Wizard to find your PiiGAB M-Bus 900S on the
network. This will work for both a network with DHCP or static IP-address configuration.
1. Go to the main menu in the PiiGAB M-Bus Setup Wizard.
2. Select Find gateways on your network.
3. Press Next to continue.
4. Your PiiGAB M-Bus 900S gateway should be listed.
5. Find your PiiGAB M-Bus 900S by the MAC-address or serial number.
6. Double click on your PiiGAB M-Bus 900S gateway.
7. Select Yes when you are asked to start the PiiGAB M-Bus 900S’s web interface.
Note: If you have placed your PiiGAB M-Bus 900S gateway on a different sub network you
might not find it in the list of available gateways.

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 9
7. Configure the PiiGAB M-Bus 900S
This section describes how the PiiGAB M-Bus 900S should be configured for M-Bus
communication using 2400 baud, UDP and port 10001 through slave port 1. All configuration
of the PiiGAB M-Bus 900S is done in the gateway’s web interface.
1. Start the PiiGAB M-Bus 900S’s web interface.
2. Specify the PiiGAB M-Bus 900S’s name and password to login.
Default login name and password are: Admin/Admin.
3. Click Configuration in the left panel.
4. Click on Master Port and configure it with these settings.
5. Press Save Settings.
6. Click on Slave port 1 and configure it with these settings.
7. Press Save settings.

Getting started PiiGAB 900 Rev 1.01.00
© PiiGAB Processinformation i Göteborg AB Page: 10
8. PiiGAB M-Bus Setup Wizard – M-Bus
communication
This section will use the PiiGAB M-Bus Setup Wizard to verify if the PiiGAB M-Bus 900S and
an M-Bus meter respond to M-Bus communication.
1. In the main menu select Test, search and configure meters.
2. Press Next to continue.
3. Select Connect using network and configure the connection as shown in the picture
below.
Note: Your PiiGAB M-Bus 900S’s IP-address may not be 192.168.10.123. The PiiGAB M-Bus
Setup Wizard only fills in the IP-address automatically as you selected in Find your PiiGAB M-
Bus 900S on your network.
4. Click Next to continue.
Autres manuels pour M-Bus 900S
1
Table des matières
Autres manuels PiiGAB Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur