PAW SolarBloC mega Manuel du propriétaire

Installation and Operation Instructions
Solar Station
SolarBloC® mega - DN 32
PAW GmbH & Co. KG
Böcklerstraße 11, 31789 Hameln, Germany
Phone: +49-5151-9856-0, Fax: +49-5151-9856-98
09/2023 99791010xx-mub-en - V02 1

Table of Contents
1 General Information...................................................................................................3
1.1 About these instructions............................................................................................3
1.2 About this product......................................................................................................3
1.3 Designated use........................................................................................................... 4
2 Safety instructions......................................................................................................5
3 Mounting and installation [specialist]...................................................................... 7
4 Commissioning [specialist]........................................................................................ 10
4.1 Flushing and filling the solar circuit..........................................................................11
4.2 Preparations before flushing.....................................................................................13
4.3 Flushing and filling.....................................................................................................14
4.4 Adjustment of the solar installation......................................................................... 15
5 Maintenance [specialist]............................................................................................ 16
5.1 Replacement / adjustment of the pressure gauge...................................................16
5.2 Draining the solar system.......................................................................................... 17
5.3 Deinstallation..............................................................................................................18
6 Scope of delivery [specialist]..................................................................................... 19
7 Technical data............................................................................................................. 21
7.1 Dimensional drawing................................................................................................. 22
7.2 Pressure drop and pump characteristic curves SolarBloC® mega.......................... 22
8 Function of the check valves [Expert]....................................................................... 23
9 Disposal....................................................................................................................... 25
10 Commissioning report................................................................................................26
11 Notes............................................................................................................................27
Table of Contents
09/2023 99791010xx-mub-en - V02 2

1 General Information
Carefully read these instructions before installation and commissioning.
Save these instructions in the vicinity of the installation for future reference.
1.1 About these instructions
These instructions describe the installation, commissioning, function and operation of the solar
station SolarBloC® mega. For other components of the solar system, such as collectors, tanks,
expansion tanks and controllers, please observe the instructions of the corresponding manufacturer.
The chapters called [specialist] are intended for specialists only.
1.2 About this product
The SolarBloC® mega is a premounted group of fittings checked for leakage to be installed in the
primary or solar circuit. The station contains important valves, fittings and safety devices for the
operation of the installation:
●Ball valves with integrated thermometers in the solar circuit (flow and return)
●Check valves in the screw connections of the mounting plate, in the flow and return line
●Pressure relief valve to prevent inadmissible overpressure
●Pressure gauge to display the installation pressure in the solar circuit
●Connection for an expansion tank
●Pump group which can be completely isolated
The expansion tank required for operation is not a part of this station and must be ordered separately.
The cap-type valve (item no. 5301), which is also separately available, allows the expansion tank to be
easily mounted and separated from the solar thermal system.
1 General Information
09/2023 99791010xx-mub-en - V02 3

1.3 Designated use
The SolarBloC® mega may only be used between the solar and storage tank circuits in solar thermal
systems taking into consideration the technical limit values indicated in these instructions. Due to its
design, the station may only be installed and operated as described in these instructions!
Only use PAW accessories with the solar station. Improper usage excludes any liability claims.
Under the influence of solar radiation, the collectors will heat up considerably.
The solar fluid in the solar circuit may heat up to more than 100 °C.
Only flush and fill the solar circuit when the collector temperatures are
below 70 °C.
1 General Information
4 99791010xx-mub-en - V02 09/2023

2 Safety instructions
The installation and commissioning as well as the connection of electrical components require
technical knowledge commensurate with a recognised vocational qualification as a fitter for
plumbing, heating and air conditioning technology, or a profession requiring a comparable level of
knowledge [specialist].
The following must be observed during installation and commissioning:
●relevant local and national regulations
●accident prevention regulations of the professional association
●instructions and safety instructions mentioned in these instructions
WARNING
Danger of scalding due to the escape of hot fluids!
With pressure relief valves, there is a risk of scalding due to the escape of vapour or
hot fluid.
Please ensure for each pressure relief valve that no personal injury or material
damage may occur due to possibly escaping medium.
►Install a discharge line.
►Observe the instructions regarding the pressure relief valve.
►The pressures for the expansion tank calculated by the plant designer and
the operating pressure of the installation must be set.
CAUTION
Risk of burns!
The valves and fittings and the pumps can become heated up to more than 100 °C
during operation.
►The insulating shell must remain closed during operation.
2 Safety instructions
09/2023 99791010xx-mub-en - V02 5

CAUTION
Personal injury and material damage due to overpressure!
Closing both ball valves in the primary circuit will separate the safety group from the
heat exchanger. A rise in temperature in the storage tank may result in high
pressures, which may lead to personal injury and material damage!
►Only close the ball valves for service and maintenance.
NOTICE
Material damage due to mineral oils!
Mineral oil products cause lasting damage to seals made of EPDM, whereby the sealant properties
are lost. We do not assume liability nor provide warranty for damage to property resulting from
sealants damaged in this way.
►It is imperative to prevent the EPDM sealing elements from making contact with substances
containing mineral oils.
►Use a silicone- or polyalkylene-based lubricant free of mineral oil such as Unisilikon L250L
and Syntheso Glep 1 from Klüber or a silicone spray.
2 Safety instructions
6 99791010xx-mub-en - V02 09/2023

3 Mounting and installation [specialist]
NOTICE
Material damage due to high temperatures!
Since the solar fluid near the collector can be very hot, the group of fittings must be installed at a
sufficient distance from the collector field. It may be necessary to install an intermediate tank in
order to protect the expansion tank.
NOTICE
Damage to property!
The installation site must be dry, stable, frost-proof and protected against ultraviolet radiation in
order to prevent material damage of the installation. Furthermore, access to the controller and
safety equipment must be guaranteed at all times during operation!
NOTICE
Damage to property!
The discharge line of the pressure relief valves must be conducted into heat-resistant collecting
containers of corresponding size. This prevents uncontrolled discharging into the environment and
enables the circuits to be refilled!
3 Mounting and installation [specialist]
09/2023 99791010xx-mub-en - V02 7

Not included in the scope of delivery!
Accessories: compression fitting
1. Push the union nut ②and the cutting ring ③onto
the copper pipe ①. The pipe must protrude at least
3 mm from the cutting ring in order to ensure the
force transmission and the sealing.
2. Insert the support sleeve ④into the copper pipe.
3. Insert the copper pipe with the plugged-on individual
parts (②, ③and ④) as far as possible into the body of
the compression fitting ⑤.
4. First, screw the union nut ②manually.
5. Tighten the union nut ②by rotating one full turn.
Secure the body of the compression fitting ⑤against
distort in order to avoid damaging the sealing ring.
3 Mounting and installation [specialist]
8 99791010xx-mub-en - V02 09/2023

1. Remove the station from the packaging.
2. Take off the thermometer handles and remove the
insulating front shell.
3. Copy the mounting holes of the wall bracket to the
mounting surface.
4. Drill the holes.
5. Fix the wall bracket to the wall using appropriate wall
plugs and screws.
6. Push the controller extension with the premounted
controller onto the solar station. Screw the mounting
plate and the wall bracket together.
7. Connect the station to the installation by using the
piping:
①Return to the collector field
②Safety group: expansion tank
③Return from the storage tank
④Flow to the storage tank
⑤Flow from the collector field
For continuous venting, we recommend to install a
microbubble resorber (for example item no. 52375) into
the flow of the solar circuit.
3 Mounting and installation [specialist]
09/2023 99791010xx-mub-en - V02 9

4 Commissioning [specialist]
Please observe the following safety instructions regarding the commissioning of the station:
WARNING
Risk of burning and scalding!
The valves and fittings may heat up to more than 100 °C. Therefore, do not clean or
fill the system when the collectors are hot (intense sunshine). Please note that hot
solar fluid leaks from the pressure relief valves in case of too high system pressure!
During venting the solar fluid may escape as vapour and result in scalding!
►Flush and fill the system only when the collector temperatures are
below 70 °C.
NOTICE
Risk of frost!
It often happens that solar systems cannot be completely drained after flushing. Thus, there is a risk
of frost damage later on when flushing with water. Therefore, only use the solar fluid used later on
for flushing and filling the solar installation.
►Use a water/propylene glycol mixture with max. 50% of propylene glycol as solar fluid.
NOTICE
Note regarding the commissioning sequence
During commissioning, fill the heating circuit first and the solar circuit afterwards. This guarantees
that the heat possibly absorbed by the collectors during commissioning can be dissipated.
NOTICE
Note regarding the expansion tank
The expansion tank must not be connected while flushing and filling in order to prevent dirt
particles from being flushed in. Please observe the instructions of the manufacturer.
4 Commissioning [specialist]
10 99791010xx-mub-en - V02 09/2023
Table des matières
Autres manuels PAW Unité de contrôle

PAW
PAW SolarBloC midi Basic Manuel du propriétaire

PAW
PAW FriwaMidi Manuel utilisateur

PAW
PAW FriwaMini Manuel utilisateur

PAW
PAW HeatBloC K33MAX DN 25 Manuel utilisateur

PAW
PAW FriwaMidi-DN 20 Manuel utilisateur

PAW
PAW FriwaMidi Manuel utilisateur

PAW
PAW K36E Manuel utilisateur

PAW
PAW K32-3/4 Manuel utilisateur

PAW
PAW HeatBloC K35 DN 25 Manuel utilisateur
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur