Palo Alto Network M-200 Manuel utilisateur

M-200 and M-600 Appliance Hardware
Reference
paloaltonetworks.com/documentation

2 M-200 AND M-600 APPLIANCE HARDWARE REFERENCE |
Contact Information
Corporate Headquarters:
Palo Alto Networks
3000 Tannery Way
Santa Clara, CA 95054
www.paloaltonetworks.com/company/contact-support
About the Documentation
• For the most recent version of this guide or for access to related documentation, visit the Technical
Documentation portal www.paloaltonetworks.com/documentation.
• To search for a specific topic, go to our search page www.paloaltonetworks.com/documentation/
document-search.html.
• Have feedback or questions for us? Leave a comment on any page in the portal, or write to us at
Copyright
Palo Alto Networks, Inc.
www.paloaltonetworks.com
© 2018-2018 Palo Alto Networks, Inc. Palo Alto Networks is a registered trademark of Palo
Alto Networks. A list of our trademarks can be found at www.paloaltonetworks.com/company/
trademarks.html. All other marks mentioned herein may be trademarks of their respective companies.
Last Revised
August 2, 2018

TABLE OF CONTENTS iii
Table of Contents
Before You Begin................................................................................................5
Tamper Proof Statement...........................................................................................................................7
Third-Party Component Support.............................................................................................................8
Product Safety Warnings.......................................................................................................................... 9
M-200 and M-600 Appliance Overview.....................................................13
M-200 Appliance Front Panel............................................................................................................... 15
M-200 Appliance Back Panel................................................................................................................ 17
M-600 Appliance Front Panel............................................................................................................... 19
M-600 Appliance Back Panel................................................................................................................ 21
M-200 and M-600 Appliance Port LEDs............................................................................................24
Install M-200 or M-600 Appliance in an Equipment Rack......................25
Install the M-200 Appliance in a 19” Equipment Rack....................................................................27
Install the M-600 Appliance in a 19” Equipment Rack....................................................................30
Connect Power to an M-200 or M-600 Appliance.................................. 33
Connect AC Power to an M-200 or M-600 Appliance................................................................... 35
Service an M-200 or M-600 Appliance...................................................... 37
Replace an M-200 or M-600 Drive..................................................................................................... 39
Replace an M-200 or M-600 Appliance System Drive.......................................................39
Replace an M-200 or M-600 Appliance Log Drive............................................................. 41
Replace an M-200 or M-600 Appliance Power Supply...................................................................45
M-200 and M-600 Appliance Specifications............................................. 47
M-200 and M-600 Physical Specifications.........................................................................................49
M-200 and M-600 Electrical Specifications.......................................................................................50
M-200 and M-600 Environmental Specifications.............................................................................51
M-200 and M-600 Miscellaneous Specifications............................................................................. 52
M-200 and M-600 Appliance Hardware Compliance Statements........ 53
M-200 and M-600 Compliance Statements...................................................................................... 55

iv TABLE OF CONTENTS

5
Before You Begin
Read the following topics before you install or service a Palo Alto Networks® next-generation
firewall or appliance. The following topics apply to all Palo Alto Networks firewalls and
appliances except where noted.
> Tamper Proof Statement
> Third-Party Component Support
> Product Safety Warnings

6 M-200 AND M-600 APPLIANCE HARDWARE REFERENCE | Before You Begin
© 2018 Palo Alto Networks, Inc.

M-200 AND M-600 APPLIANCE HARDWARE REFERENCE | Before You Begin 7
© 2018 Palo Alto Networks, Inc.
Tamper Proof Statement
To ensure that products purchased from Palo Alto Networks were not tampered with during shipping, verify
the following upon receipt of each product:
• The tracking number provided to you electronically when ordering the product matches the tracking
number that is physically labeled on the box or crate.
• The integrity of the tamper-proof tape used to seal the box or crate is not compromised.
• The integrity of the warranty label on the firewall or appliance is not compromised.
(PA-7000 Series firewalls only) PA-7000 Series firewalls are modular systems and therefore
do not include a warranty label on the firewall.

8 M-200 AND M-600 APPLIANCE HARDWARE REFERENCE | Before You Begin
© 2018 Palo Alto Networks, Inc.
Third-Party Component Support
Before you consider installing third-party hardware, read the Palo Alto Networks Third-Party Component
Support statement.

M-200 AND M-600 APPLIANCE HARDWARE REFERENCE | Before You Begin 9
© 2018 Palo Alto Networks, Inc.
Product Safety Warnings
To avoid personal injury or death for yourself and others and to avoid damage to your Palo Alto Networks
hardware, be sure you understand and prepare for the following warnings before you install or service the
hardware. You will also see warning messages throughout the hardware reference where potential hazards
exist.
All Palo Alto Networks products with laser-based optical interfaces comply with 21 CFR
1040.10 and 1040.11.
The following safety warnings apply to all Palo Alto Networks firewalls and appliances, unless a specific
hardware model is specified.
• When installing or servicing a Palo Alto Networks firewall or appliance hardware component that has
exposed circuits, ensure that you wear an electrostatic discharge (ESD) strap. Before handling the
component, make sure the metal contact on the wrist strap is touching your skin and that the other end
of the strap is connected to earth ground.
French Translation: Lorsque vous installez ou que vous intervenez sur un composant matériel de
pare-feu ou de dispositif Palo Alto Networks qui présente des circuits exposés, veillez à porter un
bracelet antistatique. Avant de manipuler le composant, vérifiez que le contact métallique du bracelet
antistatique est en contact avec votre peau et que l’autre extrémité du bracelet est raccordée à la terre.
• Use grounded and shielded Ethernet cables to ensure agency compliance with electromagnetic
compliance (EMC) regulations.
French Translation: D es câbles Ethernet blindés reliés à la terre doivent être utilisés pour garantir la
conformité de l'organisme aux émissions électromagnétiques (CEM).
• (PA-220 firewalls only) The PA-220 firewall meets the requirements of IEC 61000-4-5 surge immunity
test. To prevent damage from electrical surges on Ethernet ports, we recommend that you use an
Ethernet surge protection device with the following specifications:
• Rated for Gigabit Ethernet up to category 5E and minimum 1Gbps.
• Protection provided on all eight signal leads.
• Both line-to-line and line-to-ground/shield are provided.
• Protection device must be connected to earth ground and use shielded category 5E or higher
Ethernet cable.
Technical Specifications:
• Protective circuit complies with IEC test classifications B2, C1, C2, C3, and D1.
• Normal discharge current (core to earth ground) is 2kA per signal pair.
• Normal discharge current (core to core) is 100A.
• Total discharge current is 10kA.
•French Translation: (PA-220 uniquement) Les pare-feux PA-220 sont conformes aux exigences du test
d’immunité aux surtensions IEC 61000-4-5. Pour éviter les dommages résultant de surtension électrique
sur les ports Ethernet, il est recommandé d’utiliser un dispositif de protection contre les surtensions aux
caractéristiques suivantes:
• Gigabit Ethernet jusqu’à la catégorie 5E, débit 1 Go/s minimum.
• Protection sur les huit câbles signal.
• Le blindage et la mise à la terre “ligne à ligne” et “ligne à la terre” sont fournis.
• Le dispositif de protection doit être raccordé à la terre et un câble Ethernet blindé de catégorie 5E ou
supérieure doit être utilisé.
Caractéristiques techniques:

10 M-200 AND M-600 APPLIANCE HARDWARE REFERENCE | Before You Begin
© 2018 Palo Alto Networks, Inc.
• Le circuit de protection est conforme aux classifications de test IEC B2, C1, C2, C3, et D1.
• Le courant de décharge normal (cœur vers terre) est de 2kA par paire de signal.
• Le courant de décharge normal (cœur vers cœur) est de 100 A.
• Le courant de décharge total est de 10kA.
• Do not connect a supply voltage that exceeds the input range of the firewall or appliance. For details
on the electrical range, refer to electrical specifications in the hardware reference for your firewall or
appliance.
French Translation: Veillez à ce que la tension d’alimentation ne dépasse pas la plage d’entrée du
pare-feu ou du dispositif. Pour plus d’informations sur la mesure électrique, consulter la rubrique des
caractéristiques électriques dans la documentation de votre matériel de pare-feu ou votre dispositif.
• Do not replace a battery with an incorrect battery type; doing so can cause the replacement battery to
explode. Dispose of used batteries according to local regulations.
French Translation: Ne remplacez pas la batterie par une batterie de type non adapté, cette dernière
risquerait d’exploser. Mettez au rebut les batteries usagées conformément aux instructions.
• (All firewalls with two or more power supplies) Disconnect all power cords (AC or DC) from the power
inputs to fully de-energize the hardware.
French Translation: (Tous les pare-feux avec au moins deux sources d’alimentation) Débranchez tous les
cordons d’alimentation (c.a. ou c.c.) des entrées d’alimentation et mettez le matériel hors tension.
• (PA-7000 Series firewalls only) When removing a fan tray from a PA-7000 Series firewall, first pull the
fan tray out about 1 inch (2.5cm) and then wait a minimum of 10 seconds before extracting the entire
fan tray. This allows the fans to stop spinning and helps you avoid serious injury when removing the
fan tray. You can replace a fan tray while the firewall is powered on but you must replace it within 45
seconds and you can only replace one fan tray at a time to prevent the thermal protection circuit from
shutting down the firewall.
French Translation: (Pare-feu PA-7000 uniquement) Lors du retrait d’un tiroir de ventilation d’un pare-
feu PA-7000, retirez tout d’abord le tiroir sur 2,5 cm, puis patientez au moins 10 secondes avant de
retirer complètement le tiroir de ventilation. Cela permet aux ventilateurs d’arrêter de tourner et permet
d’éviter des blessures graves lors du retrait du tiroir. Vous pouvez remplacer un tiroir de ventilation
lors de la mise sous tension du pare-feu. Toutefois, vous devez le faire dans les 45 secondes et vous ne
pouvez remplacer qu’un tiroir à la fois, sinon le circuit de protection thermique arrêtera le pare-feu.
• (All firewalls with two or more power supplies) Disconnect all power cords (AC or DC) from the power
inputs to fully de-energize the hardware.
French Translation: (Tous les pare-feux avec au moins deux sources d’alimentation) Débranchez tous les
cordons d’alimentation (c.a. ou c.c.) des entrées d’alimentation et mettez le matériel hors tension.
The following applies only to Palo Alto Networks firewalls that support a direct current (DC) power source:
French Translation: Les instructions suivantes s’appliquent uniquement aux pare-feux de Palo Alto
Networks prenant en charge une source d’alimentation en courant continu (c.c.):
• Do not connect or disconnect energized DC wires to the power supply.
French Translation: Ne raccordez ni débranchez de câbles c.c. sous tension à la source d’alimentation.
• The DC system must be earthed at a single (central) location.
French Translation: Le système c.c. doit être mis à la terre à un seul emplacement (central).
• The DC supply source must be located within the same premises as the firewall.
French Translation: La source d’alimentation c.c. doit se trouver dans les mêmes locaux que ce pare-feu.
• The DC battery return wiring on the firewall must be connected as an isolated DC (DC-I) return.
French Translation: Le câblage de retour de batterie c.c. sur le pare-feu doit être raccordé en tant que
retour c.c. isolé (CC-I).
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Matériel informatique populaires d'autres marques

EMC2
EMC2 VNX Series Manuel du propriétaire

Panasonic
Panasonic DV0PM20105 Manuel utilisateur

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manuel utilisateur

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manuel utilisateur

Raidon
Raidon iT2300 Manuel utilisateur

National Instruments
National Instruments PXI-8186 Manuel utilisateur