New lift ADM S Manuel utilisateur

Landing call modules
MANUAL
J1 Service
J1
Service

ADMmanual
Manufacturer NEWLIFTSteuerungsbauGmbH
LochhamerSchlag8
82166Graefelfing
Tel +49 89 – 898 66 – 0
Fax +49 89 – 898 66 – 300
Mail [email protected]
www.newlift.de
Service line Tel +49 89 – 898 66 – 110
Mail [email protected]
Date of issue 30.12.2011
Author KH/TB
Release SWB
Hardware version ADM-S/ADM-D:2.4
ADM-3:3.1
ADM-XF/ADM-XK:1.2
Doc. no. hb_adm_2015-12_en
Copyright ©NEWLIFTSteuerungsbauGmbH,2015.
Thismanualisprotectedbycopyright.Allrights,includingthoseofcopying,of
reproduction,oftranslationandofmodification,inwholeorinpart,arereservedby
thepublisher.
Nopartofthisdescriptionmaybereproducedinanyformorcopiedwithan
electronicreplicationsystemwithoutwrittenpermission.
Althoughgreatcarehasbeentakenintheproductionoftextsandfigures,we
cannotbeheldlegallyliableforpossiblemistakesandtheirconsequences.

ADMmanual I
Content
1 About this manual 1
1.1 Abbreviations, characters and symbols used 1
1.2 Further information 1
1.3 How to contact us 1
1.4 General safety regulations 2
1.4.1 Applicablestandardsandguidelines 2
1.4.2 Electromagneticcompatibility(EMC) 2
1.4.3 Handlingelectroniccomponents 2
2 ADM-S and ADM-D land call module 3
2.1 Technical data 3
2.2 Terminal assignment and configuration 3
2.2.1 BusconnectionX1,X2 3
2.2.2 Jumpers 3
2.2.3 Terminalstrip 4
3 ADM-3 land call module 5
3.1 Technical data 5
3.2 Terminal assignment and configuration 5
3.2.1 BusconnectionX1,X2 5
3.2.2 Jumper 6
3.2.3 Terminalstrip 6
3.2.4 LEDandmicrofuse 7
4 ADM-M land call modul 8
4.1 Technical data 8
4.2 Terminal assignment and configuration 9
4.2.1 BusconnectionX1,X2 9
4.2.2 Jumper 9
4.2.3 Terminalstrip 9
4.2.4 Micromatch 10
4.2.5 LEDandmicrofuse 10
5 ADM-XF land call module 11
5.1 Technical data 11
5.2 Installation and wiring 11
5.3 Terminal assignment and configuration 12
5.3.1 BusconnectionX21,X22 12
5.3.2 Terminalstrips 12
5.3.3 Jumpers 13
5.3.4 Flooranddoorsideassignment 13
5.3.5 LED 14
5.3.6 Configurationofthekeyswitchinputs 14

II ADMmanual
6 ADM-XK land call module 15
6.1 Technical data 15
6.2 Installation and wiring 15
6.3 Terminal assignment and configuration 16
6.3.1 BusconnectionX21,X22 16
6.3.2 TerminalstripX1 16
6.3.3 Jumpers 16
6.3.4 Flooranddoorsideassignment 17
6.3.5 LED 17
6.3.6 Configurationofthekeyswitchinputs 17

About this manual
Abbreviations,charactersandsymbolsused
ADMmanual 1
1 About this manual
This manual contains all information about the technical data, operation and conguration of the ADM-S, ADM-
D, ADM-XF and ADM-XK land call modules
1.1 Abbreviations, characters and symbols used
The characters and symbols used in this manual have the following meaning.
ADM
Land call module; the land call modules control all equipment of the landing call panel, i.e. all buttons and dis-
play elements.
Delivery condition
Settings that are supplied as standard are marked with an asterisk .
Abbreviations for detailed information in the case of terminals:
P: Power
I: Input
O: Output
L: Low active
H: High active
Information notice
This symbol is located in front of relevant information.
1.2 Further information
The following documents, among others, are available for the FST control system and its components:
› FST Installation & Commissioning
› FST manual
› ADM manual
› FPM manual
› SAM manual
› Fire recall manual
These and other up to date manuals can be found in the download area of our website unter Service
http://www.newlift.de/service/download
1.3 How to contact us
If, after referring to this manual, you still require assistance, our service line is there for you:
Phone +49 89 – 898 66 – 110
E-mail [email protected]
Mon. - Thurs.: 8:00 a.m. – 12:00 p.m. and 1:00 p.m. – 5:00 p.m.
Fr: 8:00 a.m. – 3:00 p.m.

About this manual
Generalsafetyregulations
2 ADMmanual
1.4 General safety regulations
The land call modules must only be operated in perfect working condition in a proper manner, safely and in
compliance with the instructions, the valid accident prevention regulations and the guidelines of the local power
company.
This manual is a supplement to the FST manual and the FST Installation and Commissioning manual whose
safety guidelines must always be observed.
1.4.1 Applicable standards and guidelines
All land call modules comply with:
› the safety guidelines for the construction and installation of passenger and goods passenger lifts (DIN EN 81
Part 1 and 2).
› the conditions for the erection of high voltage installations with nominal voltages up to 1 kV (DIN VDE 0100).
› the contact protection measures in the machine room (VDE 0106).
› the data sheet on safety measures for the installation, maintenance and commissioning of lift systems (ZH
1/312).
1.4.2 Electromagnetic compatibility (EMC)
An accredited inspection authority has inspected the FST control system and its components in accordance with
the standards, thresholds and severity levels named in EN 12015/1995 and EN 12016/1995.
The FST control system and its components are:
› immune to electrostatic discharge (EN 61000-4-2/1995)
› immune to electrostatic elds (EN 61000-4-3/1997)
› immune to fast transient disturbances (EN 61000-4-4/1995)
The electromagnetic disturbance eld strengths created by the FST control system and its components do not
exceed the permissible thresholds. (EN 55011/1997).
1.4.3 Handling electronic components
› Keep the electronic assembly in its original packaging until installation.
› Before opening the original packaging, a static discharge must be performed. To do this, touch a grounded
piece of metal.
› During work on electronic assemblies, periodically perform this discharge procedure.
› All bus inputs and outputs that are not in use must be equipped with a terminator.

ADM-S and ADM-D land call module
Technicaldata
ADMmanual 3
2 ADM-S and ADM-D land call module
The ADM-S and ADM-D land call modules form the interface between the landing call panel and FST control
system. The ADM-S or ADM-D is connected to the FST via the LON bus. The ADM-S or ADM-D is
typically installed on each oor.
Both modules are based on the same hardware and are available in the following software versions:
› ADM-S: ADM Single for individual lifts
› ADM-D: ADM Double for group lifts
The ADM-S or ADM-D are either installed and pre-wired in the landing call panel or delivered loose (to be ins-
talled in the shaft).
2.1 Technical data
Description Value
Supply voltage 24 V DC ±10%
Typical power consumption 50 mA
Outputs Short circuit-proof
Length x height x depth 50 x 54 x 20 mm
Temperature range: Storage & transport / operation -20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & transport / operation
(non-condensing)
+5 – +95 % / +15 – +85 %
X2
X3 X3
X1
J1
54
48
50
25
5
5
Fig. 2.1: ADM-S and ADM-D circuit board marking
2.2 Terminal assignment and configuration
2.2.1 Bus connection X1, X2
ADM-S/.D X1 / X2 Cable colour Designation
1 black RS-485 LON bus A
2 white RS-485 LON bus B
3 red +24 V
4 violet GND or 0V
2.2.2 Jumpers
Jumper J1 is not connected!

ADM-S and ADM-D land call module
Terminalassignmentandconfiguration
4 ADMmanual
2.2.3 Terminal strip
ADM-S X3
ADM-D X3
ADM-S
function / programming
ADM-D
function / programming
Technical data
1 + 24 V + 24 V P
2 Landing call UP Landing call UP I/O; L; 350 mA / 24 V
3 Landing call DOWN Landing call DOWN I/O; L; 350 mA / 24 V
4 Landing call release Landing call release O; L; 350 mA / 24 V
5 + 24 V + 24 V P
6 Out-of-order, occupied display,
special drive
Occupied display, left O; L; 350 mA / 24 V
7 Chime, oor position 5 Chime left, special drive O; L; 350 mA / 24 V
8 Direction UP Direction UP left O; L; 350 mA / 24 V
9 Direction DOWN Direction DOWN left O; L; 350 mA / 24 V
10 GND GND P
11 GND GND P
12 Key switch 1:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
Key switch 1:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
I; L
13 Key switch 2:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
Key switch 2:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
I; L
14 Floor position 4, landing prio
display, soft output 0, soft output 1,
acoustic click
Landing prio display, acoustic click O; L; 350 mA / 24 V
15 + 24 V + 24 V P
16 Floor position bit 0 Direction DOWN right O; L; 350 mA / 24 V
17 Floor position bit 1 Direction UP right O; L; 350 mA / 24 V
18 Floor position bit 3 Occupied display, right O; L; 350 mA / 24 V
19 Floor position bit 2 Chime right, special drive O; L; 350 mA / 24 V
20 GND GND P
The values in the table correspond to the factory settings. Other I/O functions can be set using the software and
can thus deviate from the table. More detailed information can be found in the FST Installation and Commissio-
ning manual. The functions congured for you can be found in your system-specic wiring diagrams.
Terminals for which several functions are listed can be set with one of them at the factory. The "Direction" func-
tion can be congured in the FST menu as a direction of travel output or a travel continuation output.
The terminals labelled with key switches 1 and 2 can be set at the factory with the functions re recall, smoke
alarm, remote shutdown and priority landing.
Other I/O functions can be set using the software.
LED
LED Colour State Description
LD1 yellow briey ashes after switched on ADM ready
ashing or permanently illuminated hardware error

ADM-3 land call module
Technicaldata
ADMmanual 5
3 ADM-3 land call module
The ADM-3 land call modul forms the interface between the landing call panel and FST control system. The
ADM-3 is connected to the FST via the LON bus.
The ADM-3 is typically installed on each oor.
This module combines the previous modules ADM-S and ADM-D
Characteristics of the module ADM-3:
› sunken yellow Service-LED
› Service-Pin as contact area
› sunken red LED between X1 and X2
› sunken green LED between X1 and X2
› micro fuse 250 mA between X1 and X2
› additional connections X3.0 and X3.21
The ADM-3 is either installed and pre-wired in the landing call panel or delivered loose (to be installed in the
shaft).
3.1 Technical data
Description Value
Supply voltage 24 V DC ±10%
Typical power consumption 50 mA
Outputs Short circuit-proof
Length x height x depth 50 x 54 x 20 mm
Temperature range: Storage & transport / operation -20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & transport / operation
(non-condensing)
+5 – +95 % / +15 – +85 %
X1 X2
J1
X3
X3
250 mA
Service
54
48
50
25
5
5
Fig. 3.1: ADM-3 circuit board marking
3.2 Terminal assignment and configuration
3.2.1 Bus connection X1, X2
ADM-S/.D X1 / X2 Cable colour Designation
1 black RS-485 LON bus A
2 white RS-485 LON bus B
3 red +24 V
4 violet GND or 0V

ADM-3 land call module
Terminalassignmentandconfiguration
6 ADMmanual
3.2.2 Jumper
There are two contact areas on the ADM-3 module instead of Jumper J1. If necessary, gently press these con-
tact area with a screwdriver.
3.2.3 Terminal strip
The ADM can be congered as a single or double in the FST-Menu.
ADM-S X3
ADM-D X3
ADM-S
function / programming
ADM-D
function / programming
Technical data
0 Attika, bank controlle mode with
user-groups, prio selective call
prio selective call
1 + 24 V + 24 V P
2 Landing call UP Landing call UP I/O; L; 350 mA / 24 V
3 Landing call DOWN Landing call DOWN I/O; L; 350 mA / 24 V
4 Landing call release Landing call release O; L; 350 mA / 24 V
5 + 24 V + 24 V P
6 Out-of-order, occupied display,
special drive
Occupied display, left O; L; 350 mA / 24 V
7 Chime, oor position 5 Chime left, special drive O; L; 350 mA / 24 V
8 Direction UP Direction UP left O; L; 350 mA / 24 V
9 Direction DOWN Direction DOWN left O; L; 350 mA / 24 V
10 GND GND P
11 GND GND P
12 Key switch 1:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
Key switch 1:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
I; L
13 Key switch 2:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
Key switch 2:
re recall, re recall selective, re
recall reset, landing prio, landing
prio selective, landing prio super,
remote shutdown, remote shut-
down selective, smoke alarm, soft
switch
I; L
14 Floor position 4, landing prio
display, soft output 0, soft output 1,
acoustic click
Landing prio display, acoustic click O; L; 350 mA / 24 V
15 + 24 V + 24 V P
16 Floor position bit 0 Direction DOWN right O; L; 350 mA / 24 V
17 Floor position bit 1 Direction UP right O; L; 350 mA / 24 V
18 Floor position bit 3 Occupied display, right O; L; 350 mA / 24 V
19 Floor position bit 2 Chime right, special drive O; L; 350 mA / 24 V
20 GND GND P
21 Attika, bank controlle mode with
user-groups, prio selective call,
Soft-Output 0
prio selective call
Ce manuel convient aux modèles suivants
5
Table des matières
Autres manuels New lift Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur