MOA A011D Manuel utilisateur

Airconditioner A011D
Instruction Manual
English / Nederlands / Deutsch / Français
www.moacolors.com
Local air conditioners
Caution, risk of fire

Portable Airconditioner - English manual 2
EN
BEFORE USE
Before use, please read this manual carefully.
Only connect the appliance to an earthed wall socket.
This appliance is for household use only. When using electrical
appliances, basic safety precautions should always be followed to
avoid res, electric shocks, burns, or other injuries and damage. Read
these operating and safety instructions carefully.
Our powerful portable air conditioners are great cooling solutions
for single rooms, creating a comfortable atmosphere in your space.
It also has ventilation and dehumidifying function for circulating air
and removal of moisture. They’re self-contained systems that do not
require any permanent installation allowing you to move to the space in
which it is most needed. They’re commonly used in kitchen, temporary-
resided, computer rooms, garages, and many other places where
installation of Air-conditioner Outdoor Unit is limited.
The environmentally friendly R290 is used as the refrigerant. R290
has no damaging inuence on the ozone layer (ODP), a negligible
greenhouse effect (GWP) and is available worldwide. Because of its
efcient energy properties, R290 is highly suitable as a coolant for this
application. Special precautions must be taken into consideration due
to the coolant’s high ammability.
This unit uses a ammable refrigerant.
If refrigerant leaks and comes in contact with re
or heating part, it will create harmful gas and
there is risk of re.
Read the USER MANUAL carefully
before operation.
Further information is available in the
USER MANUAL, SERVICE MANUAL.
Service personnel are required to carefully read
the USER MANUAL and SERVICE MANUAL
before operation.

Portable Airconditioner - English manual 3
EN
IMPORTANT SAFEGUARDS (1/6)
1. This appliance is intended to be used by expert or trained users
in shops, in light industry and on farms, or for commercial use by lay
persons.
2. This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
3. The unit is designed only for use with R-290(propane) gas as the
designated refrigerant.
4. The refrigerant loop is sealed. Only a qualied technician should
attempt to service!
5. Do not discharge the refrigerant into the atmosphere.
6. R-290 (propane) is ammable and heavier than air.
7. It collects rst in low areas but can be circulated by the fans.
8. If propane gas is present or even suspected, do not allow untrained
personnel to attempt to nd the cause.
9. The propane gas used in the unit has no odor.
10. The lack of smell does not indicate a lack of escaped gas.
11. If a leak is detected, immediately evacuate all persons from the
store, ventilate the room and contact the local re department to advise
them that a propane leak has occurred.
12. Do not let any persons back into the room until the qualied service
technician has arrived and that technician advises that it is safe to
return to the room.

Portable Airconditioner - English manual 4
EN
IMPORTANT SAFEGUARDS (2/6)
13. No open ames, cigarettes or other possible sources of ignition
should be used inside or in the vicinity of the units.
14. Component parts are designed for propane and non-incentive and
non-sparking. Component parts shall only be replaced with identical
repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN
EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
15. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in order to
avoid a hazard.
16. The appliance shall be disconnected from its power source during
maintenance.
17. Always operate the unit from a power source of equal voltage,
frequency and rating as indicated on the product identication plate.
18. Always use a power outlet that is grounded.
19. Unplug the power cord when cleaning or when not in use.
20. Do not operate with wet hands. Prevent water from spilling onto the
unit.
21. Do not immerse or expose the unit to rain, moisture or any other
liquid.
22. Do not leave the unit running unattended. Do not tilt or turn over the
unit.
23. Do not unplug while the unit is operating.
24. Do not unplug by pulling on the power cord.
25. Do not use an extension cord or an adapter plug.
26.Do not put objects on the unit.

Portable Airconditioner - English manual 5
EN
IMPORTANT SAFEGUARDS (3/6)
27. Do not climb or sit on the unit.
28. Do not insert ngers or other objects into the air outlet.
29. Do not touch the air inlet or the aluminum ns of the unit.
30. Do not operate the unit if it is dropped, damaged or showing signs
of product malfunction.
31. Do not clean the appliance with any chemicals.
32. Ensure the unit is far away from re, inammable, or explosive
objects.
33. The unit shall be installed in accordance with national wiring
regulations.
34. Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacture.
35. The appliance shall be stored in a room without continuously
operation sources (for example: open ames, an operating gas
appliance or an operating electric heater).
36. The appliance shall be stored so as to prevent mechanical damage
from occurring.
37. Do not piece or burn, even after use.
38. Be aware that refrigerants may not contain an odour.
39. Pipe-work shall be protected from physical damage and shall
not be installed in an unventilated space, if that space is smaller than
12m².
40. Compliance with national gas regulations shall be observed.
41. Keep any required ventilation openings clear of obstruction.
42. The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specied for operation.

Portable Airconditioner - English manual 6
EN
IMPORTANT SAFEGUARDS (4/6)
Warning: Any person who is involved with working on or breaking
into a refrigerant circuit should hold a current valid certicate from
an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry, recognized assessment specication.
Warning: Servicing shall only be performed as recommended by
the equipment manufacturer. Maintenance and repair requiring
the assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of ammable
refrigerants.
43. Checks to the area:
Prior to beginning work on systems containing ammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is
minimized. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the
system.
44. Work procedure:
Work shall be undertaken under a controlled procedure so as to
minimize the risk of a ammable gas or vapor being present while the
work is being performed.
45. General work area:
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in conned
spaces shall be avoided. The area around the work space shall be
sectioned off. Ensure that the conditions within the area have been
made safe by control of ammable material.
46. Checking for presence of refrigerant:
The area shall be checked with an appropriate refrigerant detector
prior to and during work, to ensure the technician is aware of
potentially ammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with ammable refrigerants,
i.e. no sparking, adequately sealed or intrinsically safe.
47. Presence of re extinguisher:
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate re extinguishing equipment shall
be available to hand. Have a dry powder or CO2 re extinguisher
adjacent to the charging area.

Portable Airconditioner - English manual 7
EN
IMPORTANT SAFEGUARDS (5/6)
48. No ignition sources:
No person carrying out work in relation to a refrigeration system
which involves exposing any pipe work that contains or has contained
ammable refrigerant shall use any sources of ignition in such a manner
that it may lead to the risk of re or explosion. All possible ignition
sources, including cigarette smoking, should be kept sufciently far
away from the site of installation, repairing, removing and disposal,
during which ammable refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no ammable
hazards or ignition risks. “No Smoking” signs shall be displayed.
49. Ventilated area:
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree
of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
50. Checks to the refrigeration equipment:
Where electrical components are being changed, they shall be
t for the purpose and to the correct specication. At all times the
manufacturer’s maintenance and service guidelines shall be followed. If
in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using ammable
refrigerants:
– The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and
are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected;
– refrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance which may
corrode refrigerant containing components, unless the components
are constructed of materials which are inherently resistant to being
corroded or are suitably protected against being so corroded.

Portable Airconditioner - English manual 8
EN
IMPORTANT SAFEGUARDS (6/6)
51. Checks to electrical devices:
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists that
could compromise safety, then no electrical supply shall be connected
to the circuit until it is satisfactorily dealt with. If the fault cannot be
corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the
owner of the equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding.
WARNING
Install the unit in rooms which exceed 9 m².
Do not install the unit in a place where inammable gas may leak.
NOTE
The manufacture may provide other suitable example or may provide
additional information about the refrigerant odour.

Portable Airconditioner - English manual 9
EN
PARTS & LOCATION
1. Control panel 2. Air outlet with
adjustable louver
3. Handle 4. Air inlet with air lter
5. Caster 6. Drainage Hole
7. Air Exhaust
Note: The appearance is only for reference. Please see the real product
for detailed information.
1. Exhaust hose 2. Remote
3. Window kit adapter
4. Window kit 5. Drain hose

Portable Airconditioner - English manual 10
EN
PLACEMENT
1. If tipped more than 45°, allow the unit to set upright for at least 24
hours before start up.
2. Place the unit on a rm, level surface in an area with at least 50cm
of free space around it to allow for proper air circulation.
3. Do not operate in close proximity to walls, curtains, or other objects
that may block air inlet and outlet. Keep the air inlet and outlet free of
obstacles.
4. Never install the unit where it could be subject to:
- Heat sources such as radiators, heat registers, stoves or other products
that products that produce heat.
- Direct sunlight
- Mechanical vibration or shock
- Excessive dust
- Lack of ventilation, such as cabinet or bookcase
- Uneven surface
WARNING
Install the unit in rooms which exceed 9 m².
Do not install the unit in a place where inammable gas may leak.
NOTE
The manufacture may provide other suitable example or may provide
additional information about the refrigerant odour.
Table des matières
Langues :
Autres manuels MOA Climatiseur























