Rev. 1.0
Mipot S.p.A. reserve the right to modify the specifications without notice Cormòns, April,10, 2019
Page 8 of 10
Check the pairing state of END-NODE device in the “Network config page”. The state
should be “paired” and the number displayed in MST(HEX) should be the MASTER serial
number.
Check your message threshold value. Try with a message threshold (Msg Th) around
50%-60% of the total message number (Msg Nb).
A message transmission message is possible from MASTER to END-NODE and from END-
NODE to MASTER . It can be sent in Confirmed or Unconfirmed mode.
➢Complete the pairing procedure described in the previous pages.
➢Set 5 in the “Unconfirmed Tx Nb” box in Radio Config page.
This parameter indicates the number of times than a single unconfirmed message is
sent from the transmitting device.
➢Set 5 in the “Confirmed Retry Number” box in Radio Config page.
This value indicates the number of times than an confirmed message is sent if ACK is
not received.
➢Press ” WRITE” button to store the parameters into device.
➢Write the message in HEX format in the END-NODE table “DATA(HEX)”.
➢Send the confirmed or unconfirmed message by pushing selected buttons in the
END-NODE table. Message will be displayed in the master tab.