Minarik SL-15U Manuel utilisateur

User’s Manual
SL-15U
Adjustable Speed Control
for Bodine Shunt Wound
1/70 and 1/50 HP
115 VDC Motors

Copyright 2001 by
Minarik Corporation
All rights reserved. No part of this manual may be reproduced or transmitted in any form
without written permission from Minarik Corporation. The information and technical data
in this manual are subject to change without notice. Minarik Corporation and its
Divisions make no warranty of any kind with respect to this material, including, but not
limited to, the implied warranties of its merchantability and fitness for a given purpose.
Minarik Corporation and its Divisions assume no responsibility for any errors that may
appear in this manual and make no commitment to update or to keep current the
information in this manual.
Printed in the United States of America.

Safety Warnings
Note: This symbol denotes an important safety message. Please read
these sections carefully before performing any instructions contained in this
manual.
• Have a qualified electrical maintenance technician install,
adjust and service this equipment. Follow the National
Electrical Code and all other applicable electrical and safety
codes, including the provisions of the Occupational Safety
and Health Act (OSHA), when installing equipment.
• Reduce the chance of an electrical fire, shock, or explosion
by proper grounding, over current protection, thermal
protection, and enclosure. Follow sound maintenance
procedures.
i

ii
Table of Contents
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Alternative Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Maximum Speed and Regulation (IR COMP) Adjustment . . . . . . . . . . . . . . . . . . . . . . .9
Standard Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Speed Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Adjustable / Maximum Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Multiple Fixed Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Adjustable Speeds in Two or More Non-Overlapping Speed Ranges . . . . . . . . . . . . . .18
Multiple Full Range Adjustable Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
External Signal Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
High Speed Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Run / Stop Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Run / Stop Using Normally Closed Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Run / Stop Using Normally Open Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

iiiTable of Contents
Reversing Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Reversing with a Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Reversing with Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
DC Shunt Wound Motor Dynamic Braking Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Gearmotor Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Dynamic Braking Circuit Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Run/Stop with Dyanmic Braking using a Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . .30
Run/Stop Dynamic Braking using a Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Reversing with Dynamic Braking Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Reversing with Dynamic Braking using a Rotary Switch . . . . . . . . . . . . . . . . . . . . . . .33
Reversing with Dynamic Braking using Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Limit Switch Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Toggle Switch Reversing with Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Relay Reversing with Dynamic Braking and Limit Switches . . . . . . . . . . . . . . . . . . . . .40
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Unconditional Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .inside back cover

iv
Illustrations
Figure 1. Maximum Speed & Regulation Trimpot Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Figure 2. SL15U Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Figure 3. Maximum Speed and Regulation Trimpot Locations . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Figure 4. Adjustable / Fixed Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Figure 5. Multiple Fixed Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Figure 6. Two Non-Overlapping Speed Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Figure 7. Two Full Range Adjustable Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Figure 8. External Signal Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Figure 9. Field Weakening Resistor for High Speed Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Figure 10. Run / Stop Using Normally Closed Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Figure 11. Run / Stop Using Normally Open Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Figure 12. Reversing with Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Figure 13. Reversing with Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Figure 14. Run / Stop Dynamic Braking with Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Figure 15. Run / Stop Dynamic Braking using a Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Figure 16. Rotary Switch Reversing with Dynamic Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Figure 17. Reversing with Dynamic Braking using Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Figure 18. Toggle Switch Reversing with Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Figure 19. Relay Reversing / Braking with Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

The Model SL15U Minarik adjustable speed control is a full wave,
solid state device that is designed to control and vary the speed of
Bodine 1/70th and 1/50th HP, 115 VDC shunt wound motors. The
control has choke/capacitor filtering to assure the controlled motor
will be extra quiet, smooth and cool running. In a typical application
2% base speed regulation is provided with the help of temperature,
line voltage, and IR compensation. The control features a speed
range of 25:1, adjustable IR compensation, and a maximum speed
adjustment to limit high speed operation. The Model SL15U Minarik
adjustable speed control is a U.L. (Underwriters Laboratories)
recognized component, File E35603.
1
General Information

2
Features
• Choke/Capacitor Filtering
• Temperature Compensation
• 2% Base Speed Regulation (Typical Application)
• Maximum Speed Adjustment
• Adjustable IR Compensation
• Line Starting and Stopping
• Line Voltage Compensation
• Full Wave Armature and Field Supply

3
Input Voltage 115 VAC, 50/60 Hz Single Phase
Maximum Input current 0.9 Ampheres
Output Armature Voltage 0 - 115 VDC
Output Armature Current 0.25 Amperes
Output Field Voltage 100 VDC
Output Field Current 0.2 Amperes
Weight 8.0 Ounces
Ambient Temperature Range 10° thru 40° Centigrade
Specifications

4
Dimensional Data
SO1
2.625
[67]
3.000
[76.2]
0.1875 [5]4.125 [105]
4.500 [114]
REG
P3
MAX SPD
P2
Figure 1. Maximum Speed & Regulation Trimpot Locations
ALL DIMENSIONS IN INCHES [MILLIMETERS]
Table des matières
Autres manuels Minarik Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur