Microgate MicroGate MG1-1000 Manuel utilisateur

MicroGate™ Online Kitchen™ Gateway
User Guide
MG1-1000
January 2005
Part Number: 4911000-010
Revision Number: A3
MicroGate™ User Manual 1

TABLE OF CONTENTS
I. INTRODUCTION............................................................................................................................... 3
II. FEATURES AND SPECIFICATIONS............................................................................................. 5
ARCHITECTURE .......................................................................................................................................... 5
SERIAL INTERFACE PORT #1 AND PORT #2 ................................................................................................. 5
NETWORK INTERFACE ................................................................................................................................5
NAFEM DATA PROTOCOL MIB COMPATIBILITY....................................................................................... 5
POWER ....................................................................................................................................................... 5
ENVIRONMENTAL ....................................................................................................................................... 6
PHYSICAL SPECIFICATIONS......................................................................................................................... 6
WARRANTY ................................................................................................................................................ 6
III. HARDWARE DESCRIPTION.......................................................................................................... 7
LED INDICATORS ....................................................................................................................................... 8
POWER CONNECTORS PIN ASSIGNMENT ..................................................................................................... 8
RS232 SERIAL PORT PIN ASSIGNMENT ...................................................................................................... 9
RS485 SERIAL PORT PIN ASSIGNMENT ...................................................................................................... 9
ETHERNET (RJ45) CABLE SPECIFICATIONS AND PIN ASSIGNMENTS......................................................... 11
IV. INSTALLATION AND CONFIGURATION................................................................................. 12
SYSTEM REQUIREMENTS .......................................................................................................................... 12
CONNECT THE SYSTEM............................................................................................................................. 12
Basic Installation Procedure .............................................................................................................. 12
Basic Network Configuration Procedure............................................................................................ 13
V. PART NUMBER SELECTION....................................................................................................... 16
VI. LIMITED WARRANTIES .............................................................................................................. 17
MicroGate™ User Manual 2

I. Introduction
•Everything you need for full
NAFEM protocol compliance
•Translates and organizes your
legacy equipment's data into the
NAFEM Data Protocol framework
•Supports all of the MIBs defined
by the NAFEM Data Protocol
Group
•Built-In Web Server
•Optional Modem for installations
without a network infrastructure
•Connect up to 253 equipment with
one MicroGate™
•Firmware Upgradeable in the field
as protocol standards change
E-Control Systems MicroGate™ is one of the most cost-effective and versatile gateways
for adding the NAFEM (North America Association of Food Equipment Manufactures)
Data Protocol and Ethernet connectivity into any equipment. Whether you're an
equipment manufacturer, systems integrator, or IT manager, the cost, functionality, and
flexibility of the MicroGate™ makes it the ideal product for any Online Kitchen™
application.
The MicroGate™ incorporates all essential networking functions including a full-featured
TCP/IP stack, 10Base-T Ethernet connection, real-time operating system, embedded Web
Server, optional modem, and battery-backed memory.
Feature-Rich Cost-Effective Solution
The MicroGate™ incorporates the latest in Flash and SDRAM technology to give the
best feature/price/performance ratio on the market. Using the latest in memory
technologies allows up to 253 pieces of equipment to be connected to one MicroGate,
further reducing the cost of the overall system. Complex menu recipe changes, firmware
updates, or set point changes can be done without disrupting any of the other services
running on the MicroGate™.
Flexibility
As the demand for updates and new features arise, the MicroGate™ can be updated from
any location on the Ethernet network. This eliminates the need to call for service or
replace the hardware itself. All updates and features are added using a standard Web
Browser, like Microsoft® Internet Explorer, or through bulk transfer facilities specified
in the NAFEM data protocol.
MicroGate™ User Manual 3

Total Online Kitchen™ Solution Package
Coupled with E-Control Systems' enterprise Raptor Web Software™, equipment
manufacturers, systems integrators, and IT professionals have a total Online Kitchen™
system to help manage a fully integrated restaurant. Never before has there been such a
synergy between all aspects of the restaurant.
MicroGate™ User Manual 4

II. Features and Specifications
Architecture
CPU: Advanced High Performance Motorola 32-bit embeddedPowerPC™ Network
Processor with 66 MIPS at 50 MHz
Memory: 16 Mbytes of SDRAM (expandable to 64 Mbytes)
2 Mbytes of Flash (expandable to 16 Mbytes)
512 Kbytes of battery-backed SRAM (optional)
Real time clock with battery backup
Serial Interface Port #1 and Port #2
Interface Type: CMOS, RS232, or RS485
Data Rates: 300 to 115.2 kbps
Characters: 7 or 8 bits
Stop Bits: 1 or 2
Control Signals (for CMOS and RS232 only): RTS, CTS, DTR, DSR, and DCD
Protocols: MODBUS ™RTU, MODBUS ™ASCII, BACNET®, or any custom
proprietary protocol
Network Interface
Interface: 10Base-T Ethernet (IEEE 802.3)
Connector: RJ45
Protocols: TCP, UDP, IP, DHCP, BOOTP, ICMP, IGMP, ARP, PPP, SNMP,
SMTP, FTP (client and server), TFTP (client and server), HTTP, and
TELNET
NAFEM Data Protocol MIB Compatibility
Administration
Asset Management
Bulk Transfer
Clock Calendar
Inventory Management
Maintenance
Monitor (with history)
Notify
Security
Traps
Utility
Power
Input Voltage: 5VDC +/-5%
Without Modem:
Input Current (25 MHz Clock): 330mA max
Input Current (50 MHz Clock): 450mA max
MicroGate™ User Manual 5

With Modem:
Input Current (25 MHz Clock): 490mA max
Input Current (50 MHz Clock): 610mA max
Environmental
Operating: 0 C to 70 C (32 F to 158 F)
Storage: -40 C to 85 C (-40 F to 185 F)
Humidity: Maximum 95% Relative Humidity, non-condensing
Altitude: 10,000 ft (3048 m) max
Physical Specifications
TOLERANCES
.010 Inches 4701000A1
Figure 1
Without Modem:
Dimensions: 4.75x3.00x0.80 inches (120.7x76.2x20.4 mm)
Weight: 3.1 oz (88 grams)
With Modem:
Dimensions: 4.75x3.00x1.09 inches (120.7x76.2x27.7 mm)
Weight: 3.3 oz (94 grams)
Warranty
1-year limited warranty
MicroGate™ User Manual 6

III. Hardware Description
The MicroGate™ is meant to be connected between a local network/internet (using the
LAN Port) and the equipment(s) (using any of the serial interfaces). The MicroGate™
also includes 4 LED indicators to simplify installation and network troubleshooting. The
following figure shows the components/connectors of the gateway:
J7
J3
1
E1
E2
J2
J12
J11
J1
++
J6
J14
J8
J10
1
J13
J9
1
J5
J4
MODEM
(OPTIONAL)
DS1 DS2 DS3 DS4
2
1
2
1
2
1
2
2
12
12
BATTERY
(OPTIONAL)
Figure 2
Table 1 - Component List
Designator Item Description
J1 LAN/Ethernet Port 10 MBit Ethernet Port (RJ45). Connects
gateway to the Internet, LAN, or WAN.
J2 Modem Port (Optional)
Modem Port (RJ11). Connects gateway
to the Internet or an external PC using a
telephone line (Optional)
J3 Power Connector Supplies +5V power to board
J4 RS232 Serial Ports #1 RS232 Levels for Serial Port #1
J5 3.3V TTL Serial Port #1 3.3V TTL Levels for Serial Port #1
J6 3.3V TTL Serial Port #2 3.3V TTL Levels for Serial Port #2
J7 RS485 Serial Port #1 and #2 RS485 Levels for Serial Port #1 and #2
J8 Do Not Connect Do not connect. Used for future
expansion
J9 RS232 Serial Ports #2 RS232 Levels for Serial Port #2
J10 Do Not Connect Do not connect. Used for factory
programming
J11-J14 Modem Used to connect optional Modem Module
DS1-DS4 Diagnostic LEDs Used for installation and troubleshooting.
MicroGate™ User Manual 7

LED Indicators
Table 2 - LED Indicators
Designator Name Condition Status
On
The Ethernet Port
has established a
valid network
connection
DS1 Link (green)
Off
Network
connection does
not exist, or bad
cable.
DS2 Activity (green) Flashing
The Ethernet Port
is transmitting or
receiving traffic
DS3 Heartbeat (green) Flashing (1 sec rate) Gateway is alive
and running
On The MicroGate is
receiving power
DS4 Power (green)
Off
The MicroGate is
not receiving
power
Power Connectors Pin Assignment
Table 3 - J3 Power Connector
Pin
Number Name Description
1 GND Signal/Power Ground
2 +5V +5V power (must be regulated +/-5%)
3 +5V +5V power (must be regulated +/-5%)
4 GND Signal/Power Ground
Table 4 - Flying Leads Power Connector (Special Order)
Designator Name Description
E1 GND Signal/Power Ground
E2 +5V +5V power (must be regulated +/-5%)
MicroGate™ User Manual 8

RS232 Serial Port Pin Assignment
Table 5 - J4 (RS232 Channel #1) or J9 (Channel #2)
Pin
Number Name Description Type
1 CD Carrier Detect Input
2 DSR Data Set Ready Input
3 RX Receive Input
4 RTS Request To Send Output
5 TX Transmit Output
6 CTS Clear To Send Input
7 DTR Data Terminal Ready Output
8 RI Ring Indicator Input
9 Ground Ground Power
10 +5V
Supply voltage, Must be regulated if
power to board is being supplied from this
pin (Option must be specified when
ordering)
Input
RS485 Serial Port Pin Assignment
Table 6 - J7 RS485 Channel #1
Pin
Number Name Description Type
1 RS485_RX+ Non-Inverting Receiver Input
(Full Duplex Mode) Input
3 RS485_RX-
Inverting Receiver Input
(Full Duplex Mode) Input
5 RS485_GND RS485 Ground
(Not signal Ground!!!) Power
RS485_TX+ Non-Inverting Driver Output
(Full Duplex mode) Output
7
RS485_TX/RX+
Non-Inverting Receiver Input /
Driver Output (Half Duplex
mode)
Input/Output
RS485_TX- Inverting Driver Output
(Full Duplex mode) Output
9
RS485_TX/RX-
Inverting Receiver Input /
Driver Output (Half Duplex
mode)
Input/Output
MicroGate™ User Manual 9

Table 7 - J7 RS485 Channel #2
Pin
Number Name Description Type
2 RS485_RX+ Non-Inverting Receiver Input
(Full Duplex Mode) Input
4 RS485_RX- Inverting Receiver Input
(Full Duplex Mode) Input
6 RS485_GND RS485 Ground
(Not signal Ground!!!) Power
RS485_TX+ Non-Inverting Driver Output
(Full Duplex mode) Output
8
RS485_TX/RX+
Non-Inverting Receiver Input /
Driver Output (Half Duplex
mode)
Input/Output
RS485_TX- Inverting Driver Output
(Full Duplex mode) Output
10
RS485_TX/RX-
Inverting Receiver Input /
Driver Output (Half Duplex
mode)
Input/Output
MicroGate™ User Manual 10
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur