Specifications
Power
Supply Range..................................................................................................................................5 to 30 Volts DC
Max Operang Current .................................................................................................... 25mA @ 5V, 5mA @30V
Typical Operang Current ......................................................................................... 8.8mA @ 12V, 5.2mA @ 24V
Field Connections
Terminaon................................................................................................ Pluggable Screw Terminal, 26-16 AWG
+ Power Supply (+) ......................................................................................................................................... Pin 1
- Power Supply (-).......................................................................................................................................... Pin 2
G Serial Port Ground Internally connected to Supply (-)................................................................................. Pin 3
TX B RS-485 (+), RS-232 Transmit ................................................................................................................... Pin 4
RX A RS-485 (-), RS-232 Receive ..................................................................................................................... Pin 5
HART Modem
Terminaon...............................................................................................Pluggable Screw Terminals, 26-12 AWG
Connecon Method ............................................................................... Transformer Isolated, Capacitor Coupled
Loop Isolaon..................................................................................... 3000Vrms 1 min Pri-Sec Dielectric Strength
DC Loop Voltage.................................................................................................................................... 50Vdc Max
Demodulaon Jier ................................................................................................................. 12% of 1 bit Typical
Carrier Detect Threshold..................................................................................................................100mV Typical
Leakage to Process Loop .......................................................................................................................±10μA Max
Serial Port
Baud Rates .........................................................................1200, 2400, 4800, 9600, 14400, 19200, 39400, 57600
Parity............................................................................................................................................ None, Odd, Even
Protocol................................................................................................. HART or Modbus-RTU, Commands 3,6,16
Floang point byte order ............................................................................................ AD-CD or CD-AB (swapped)
Number of polled HART devices ..................................................................................................................1 to 16
Variables per polled HART device .................................................................................................(4) PV, SV, TV, FV
Supported Modbus-RTU Commands .......................................................................................................... 3, 6, 16
Surge Protecon.................................................................................................. 600W Silicone Avalanche Diodes
±15kV (HBM) ESD Protected Bus (RS-232 or RS-485)
RS-485 Mode
Driver Output Voltage................................................................................. 2V Min Unloaded, 1.5V Min RL = 50Ω
ΔInput Threshold Receive Voltage ............................................................................................................ +/- 0.2V
Receiver Input Hysteresis....................................................................................................................... 35 mV Typ
Receiver Input Current....................................................................................................................... +/- 1mA Max
Does not include RS-485 terminaon resistor
• Auto transmit control
• Power Up/Down glitch-free permits live inseron or removal
• Common mode range permits +/-7V ground difference
RS-232 Mode
Receiver Input Voltage Range ...................................................................................................................... +/-25V
Receiver Input Threshold ............................................................................................................VIL 1.1V, VIH 1.6V
Receiver Input Hysteresis...............................................................................................................................35mV
Transmier Output ..................................................................................................................................+/-5V Typ
USB
Connector ..................................................................................................................................................... USB-B
Type & Sengs ..................................................................................... FTDI Virtual Com Port, 1200 Baud, 8, O, 1
Protocol...................................................................HART or Modbus-RTU, Slave address 250, Commands 3,6,16
HART LED
Green ........................................................................................................................ HART Modem is transming
Red ................................................................................................................................. HART modem is receiving
COM LED
Green ............................................................................................................................. Serial Port is Transming
Red ......................................................................................................................................Serial Port is Receiving
7