6
dc1937bf
DEMO MANUAL DC1937B
USING THE LTC3350 SOFTWARE
The LTC3350 program provides the ability to measure
and monitor the system voltages and currents plus the
health of the supercapacitors. It also allows the user to
set up alarms to report on specific events such as power
fail or cap measurement done. Refer to Figure 5 for an
illustration of the LTC3350 control window.
VIEW LTC3350 PRODUCT PAGE button opens an Internet
browser and searches the Linear Technology Corporation
website for information on the LTC3350 when an Internet
connection is available.
CAP and ESR Measurement START button starts a ca-
pacitor and ESR measurement. An indicator below the
START button indicates the status of the capacitor/ESR
measurement. The different states are; In Process, Done,
Pending or Failed.
Number of Caps Selected text box indicates the number
of capacitors selected using the CAP_SLCTx pins.
SMBALERT Detected indicator indicates if an SMBALERT
has been detected or not.
Clear SMBUS ALERT button sends an SMBus alert re-
sponse address to clear the SMBALERT. Note, the condi-
tion that caused the SMBALERT must be cleared before
the SMBALERT signal can be cleared.
CAP text box indicates the latest measured capacitance in
Farads for large capacitors and mF for smaller capacitors.
This measurement is based on the CAP scale setting in the
control register plus the Current and Oscillator Resistor
Settings on the Hardware Config tab.
ESR text box indicates the latest measured ESR in mΩ.
VCAP text box indicates the latest VCAP voltage in Volts.
ICHRG text box indicates the latest measured charge/
boost current in amps. This measurement is based on the
RSNSC setting on the Hardware Config tab.
VCAPx text box indicates the latest measured capacitor
voltage in Volts for the corresponding VCAP.
VIN text box indicates the latest measured input voltage
in Volts.
IIN text box indicates the latest measured input current in
amps. This measurement is based on the RSNSI setting
on the Hardware Config tab.
VOUT textbox indicates the latest measured VOUT in Volts.
GPImon
text box indicates the latest measured GPI voltage
in Volts. An internal buffer can be enabled for measuring
high impedance inputs.
Die Temp text box displays the latest internally measured
die temperature in °C.
Register text boxes displays the associated register values
in hexadecimal format.
Read Values button causes the LTC3350 to read all of the
ADC measured values. This is useful when the LTC3350
GUI “Auto Update” is disabled.
Auto Update Enable/Disable button causes the LTC3350
to read all of the LTC3350 registers periodically and writes
to any register changed when enabled. The Read Values,
Read All, or Update All buttons can be used instead to
update the registers when in the disabled state.
Read All button causes the LTC3350 to read all of the
LTC3350 registers. This is useful when the LTC3350 GUI
Auto Update is disabled.
CHARGER CONTROL TAB
The Charger Control tab contains the indicators and con-
trols for the capacitor charger and monitor plus the GPI
buffer enable as shown in Figure 5.
ChargerStatusSTATUSBitsindicateswhentheassociated
chrg_status register bits are set. See the data sheet from
more information on these bits.
Charger Status Read text box displays the last read
chrg_status register value in hexadecimal format.
CAP ESR Period text box allows the user to set a period
in which the LTC3350 will perform a capacitance and
ESR measurement. The text box is formatted in hours,
minutes, and seconds. The LSB for the CAP ESR Period
register is 10 seconds.
CAP ESR Period Write text box displays the value that
will be or has been written to the cap_esr_period register
value in hexadecimal format.
CAP ESR Period Read text box displays the last value read
from the cap_esr_period register in hexadecimal format.