1.0 PRODUCT OVERVIEW AND FEATURES....................................................................... 1
1.1 Description...................................................................................................................... 1
1.2 Features .......................................................................................................................... 1
1.3 Specifications ................................................................................................................. 2
2.0 SAFETY NOTES................................................................................................................. 3
3.0 APPLICATION MODULE DESCRIPTION....................................................................... 4
4.0 INSTALLATION ................................................................................................................. 5
5.0 LB-1000 LOCAL SETTINGS AND TOUCH SCREEN DISPLAY ................................... 7
5.1 Home Screen Page 1.................................................................................................... 7
5.2 Home Screen Page 2.................................................................................................... 8
5.3 Home Screen Page 3.................................................................................................... 8
6.0 WEB NETWORK MANAGEMENT AND SNMP FUNCTIONS ................................... 10
7.0 WARRANTY AND RMA POLICY .................................................................................. 15

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
1 | P a g e
LB-1000-CM
User Manual
1.0 PRODUCT OVERVIEW AND FEATURES
1.1 Description
The LB-1000-CM system management module is mounted in the last slot labelled “NM” on the
far right of LB-1000 Headend platform to provide local monitoring and configuration, plus remote
management. The control module has a built-in touch screen TFT display used for local setting of
application modules and for monitoring the LB-1000 status. The touch screen folds into the control
module to save space. LB-1000-CM provides monitoring and configuration through RJ-45 LAN
port using a PC compatible Web graphical user interface (GUI). It also integrates the SNMP
protocol and the SCTE-HMS-MIBs for remote access via standard SNMP agent.
1.2 Features
•Short circuit protection
•Touch screen display for local monitoring and setting
•Touch screen folds into the control module to save space
•RJ45 Ethernet port for communication with Web GUI and SNMP
•LEDs for power supply status indication
•Back up, Copy and Restore functions allow easy replacement of application modules

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
2 | P a g e
LB-1000-CM
User Manual
1.3Specifications
PARAMETER
SPECIFICATION
Communication Interface
Ethernet Port
Standard RJ45
Data Rate
10/100M Self adapting
Communication protocol
Standard SNMP protocol
Data format
RFC and Standard SCTE-HMS-MIB
General
Operating Temperature
-20 to +50 ºC (-4 to 122 ºF)
Storage Temperature
-40 to 85 ºC (-40 to 185 ºF)
Relative Humidity
Max. 95% non-condensing
Dimensions
2.2cm(W)x12.1cm(H)x43.8cm(D)
Weight
1 Kg
Power Consumption
< 5 W

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
3 | P a g e
LB-1000-CM
User Manual
2.0 SAFETY NOTES
Failure to comply with these safety precautions and with the general or specific safety precautions
described elsewhere in the LB-1000 series manual violates the safety standards of the design,
manufacture, and intended use of the device. Lindsay Broadband Inc. assumes no liability for the
customer’s failure to comply with these precautions.
CAUTION: Do not operate the chassis outside of its maximum ratings. Doing so may result in
unsatisfactory performance, unit failure, shortened unit life span, or a safety hazard.
CAUTION: Do not attempt to modify or service any part of this chassis not specifically referred to
as replaceable in this manual. Doing so voids the warranty. Return the chassis to company for
service and repair.
CAUTION: Do not restrict air flow in front of or behind the chassis. The module should be operated
in an ambient environment between -20 and 50ºC (32 and 122ºF).
CAUTION: Store the chassis away from corrosive materials, at a temperature between -40 to 85
ºC (-40 to 185 ºF), and with no more than 95% humidity, non-condensing.
CAUTION: To avoid damaging the touchscreen LCD, please do not tap it with anything sharp or
apply excessive pressure to it with your fingertips. It is recommended to use fingers when you
use the touch screen LCD.
NO SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
4 | P a g e
LB-1000-CM
User Manual
3.0 APPLICATION MODULE DESCRIPTION
Figure 1: LB-1000-CM Front and Rear Panel
Front Panel
1. Status LED will be green when the power supply module is operating normally and will be
red when there is an alarm.
2. RESET PUSH BUTTON is used to execute the chassis reset function.
3. Handle to draw the TFT screen in/out of the module.
4. Handle to draw the module in/out of the chassis.
Rear Panel
5. PIN CONNECTOR for DC power and signals to the chassis backplane, connector type is
male.
6. RJ-45 PORT for Web GUI and SNMP communication.

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
5 | P a g e
LB-1000-CM
User Manual
4.0 INSTALLATION
The network management control module can be installed only in the special slot on the far right
of the front face of the rack. It is inserted into the rack from the front position. When installing the
module, notice that the TFT display is accessible from the front of the control module. Be very
careful when inserting the LB-1000-CM to protect the display from any damage and make sure
the module is installed in place.
1) Gently insert the LB-1000-CM module into right most slot labelled “NM” (Only!) in the
front of the chassis. Be careful to align the metal guide rails on the top and bottom of
the module to the chassis housing.
2) Completely push the LB-1000-CM module into the special slot on the right of the rack.
Ensure that the LB-1000-CM module is reliably connected to the LB-1000-CH rear
panel. On successful connection you will hear two beeps and it will be automatically
powered on. Appropriate Status LED for power supply with light up.
Figure 2: LB-1000-CM Installation and connections

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
6 | P a g e
LB-1000-CM
User Manual
3) Draw the touch screen module out gently using the handle. The touch screen can be
used to monitor and set parameters for different application modules and chassis.
CAUTION: To avoid damaging the touchscreen LCD, please do not tap it with anything sharp or
apply excessive pressure to it with your fingertips. It is recommended to use fingers when you
use the touch screen LCD.
4) Use an Ethernet cable to connect RJ-45 Ethernet port on the rear panel of LB-1000-
CM and your computer and run the SNMP software or launch the Web GUI. Refer to
the software instructions for the detailed operation.

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
7 | P a g e
LB-1000-CM
User Manual
5.0 LB-1000 LOCAL SETTINGS AND TOUCH SCREEN DISPLAY
Once the LB-1000-CM is powered up and operating normally, gently draw the touch screen
module out using the handle on the LB-1000-CM front panel. The touch screen can be used to
set and monitor the parameters of the chassis.
5.1 Home Screen Page 1
The startup interface (or home screen) is automatically displayed on the screen as the LB-1000-
CM is powered and operating normally. Tap the Scroll Up and Scroll Down buttons or drag the
scroll bar Up/Down on the touch screen to see the next page of the home screen.
Figure 3: Home Screen - Page 1
Click on the application modules 1 to 18 to browse through menu options for specific application
module. The selected application module will be highlighted.
Hardware/Software version and Operating temperature of the LB-1000 is displayed on home
screen. The cooling fan status and power supply status can also be monitored.

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
8 | P a g e
LB-1000-CM
User Manual
The home screen can be used to set alarm buzzer ON/OFF and change unit of Optical power
measurement between dBm/mW.
5.2 Home Screen Page 2
The next page of the home screen allows to perform functions like backup, copy and restore
settings for a specific application module so they can be re-used on a similar module. Screen off
time, screen lock using password and display skin color can also be changed. Network
parameters can be configured. Restart button allows for soft reset of the system.
Figure 4: Home Screen - Page 2
5.3 Home Screen Page 3
Network management firmware version, serial number and run time are displayed on the last
page of home screen.
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur