L&W SC-300 E Manuel utilisateur

C H A P T E R O V E R V I E W
Operating Instructions ...............................................................................................................
............................................................................................................................................................
............................................................................................................................................................
............................................................................................................................................................
Attachment ....................................................................................................................................
A
B
C
D
E
Manufacturer in terms of 97/23/EC
The full name and address of the manufacturer is:
Lenhardt & Wagner GmbH
An der Tuchbleiche 39
68623 Hüttenfeld / Germany
Phone: +49 (0) 62 56 - 85 88 0 - 0
Fax: +49 (0) 62 56 - 85 88 0 - 14
E-Mail: service@lw-compressors.com
Internet: www.lw-compressors.com

S E R V I C E I N F O R M A T I O N / W A R R A N T Y
Compressor information
Type designation
Serial number
Date of construction
Purchase information
Purchase date
First commissioned on
Warranty period
Dealer's stamp
Warranty
L&W will uphold warranty claims made during a period of 12 months from the invoice date.
If the compressor was purchased from an official L&W dealer, the date on the dealer's invoice is
valid. Warranty claims can only be made on presentation of the original invoice.
Should verifiably defective parts have been delivered, we will decide to either replace the parts or
repair them. The resulting transport and assembly costs will be invoiced.
No reduction of the purchase price or changes to the contract can be made. The parts for which a
claim is being made should be kept safe by the purchaser and, when requested, sent to us at their
cost. Replaced parts become the property of L&W. If maintenance work is carried out without our
knowledge or permission by the purchaser or a third party, we are absolved from any liability for
warranty claims. As a matter of principle, warranty claims can only be made by the initial purchaser.

A
Operating Instructions
Breathing Air Compressor
LW SC-300 E / LW SC-350 E
Version: 12/22-E

Page A - 2
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
T A B L E O F C O N T E N T S
General Information and Technical Data
General Information / Description of Warning Symbols .................................................................... 4
Scope of Delivery .............................................................................................................................. 5
Technical Data .................................................................................................................................. 6
Unit Assembly ................................................................................................................................... 7
Switchboard ..................................................................................................................................... 8
Flow chart ......................................................................................................................................... 9
Safety Precautions
Intended Use / Operators ................................................................................................................ 11
Safety instructions on the unit ........................................................................................................ 12
General Safety Precautions ............................................................................................................. 13
Unit customised safety notices ........................................................................................................ 14
Maintenance instructions ................................................................................................................ 15
Transportation instructions / Safety regulations .............................................................................. 16
Installation
Installation in closed rooms ............................................................................................................ 18
Dimensions ...................................................................................................................................... 19
Minimum distances ......................................................................................................................... 20
Ventilation ...................................................................................................................................... 21
Electrical Installation ................................................................................................................ 22 - 23
Operation
Important operation instructions .................................................................................................... 25
First commissioning ................................................................................................................. 26 - 28
Daily commissioning ....................................................................................................................... 29
Filling procedure ............................................................................................................................. 30
Switch off the compressor .............................................................................................................. 31
Remedying faults .............................................................................................................. 32 - 36
Maintenance and Service
Service, Repair and Maintenance .................................................................................................... 38
Maintenance Lists / Maintenance Intervals ............................................................................... 39 - 42
Check V-belt tension / Tension V-belt ............................................................................................... 43
Compressor lubrication / Check oil level .......................................................................................... 44
Oil change ...................................................................................................................................... 45
Oil filter maintenance ..................................................................................................................... 46
Final pressure switch ....................................................................................................................... 47

Page A - 3
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
T A B L E O F C O N T E N T S
Maintenance and Service
Automatic condensation dump system ........................................................................................... 48
Oil / Water separators 2nd stage - maintenance ............................................................................. 49
Oil / water separators final stage - maintenance ............................................................................. 50
Pneumatic condensate valve - maintenance .................................................................................... 51
Filter housing / Filter cartridge ........................................................................................................ 52
Filter cartridge change ..................................................................................................................... 53
Filter housing - Maintenance ........................................................................................................... 54
Inlet filters / Inlet filter cartridge change ......................................................................................... 55
Cylinder heads and valves ............................................................................................................... 56
Replace inlet and outlet valve 1st stage ................................................................................... 57 - 58
Replace inlet and outlet valves 2nd and 3rd stage .......................................................................... 59
Safety valves ................................................................................................................................... 60
Pressure maintaining / non return valve .......................................................................................... 61
Safety valve test .............................................................................................................................. 62
Leak test ......................................................................................................................................... 63
Pressure gas vessel test ................................................................................................................... 64
Maintenance records ............................................................................................................... 65 - 70
Storage
Conservation / storage of the compressor ........................................................................................ 71
De-conservation, commissioning .................................................................................................... 71
Transportation instructions / Disposal ............................................................................................. 72

Page A - 4
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
Warning
Indicates a potentially hazardous situation which, if not avoided, could result in physical
injury or damage to the product or environment.
Caution
Indicates an imminently hazardous situation which, if not avoided, could result in serious
injury, physical injury or death.
General Information
We strongly recommend reading this manual thoroughly prior to operation and follow all the safety
precautions precisely. Damage resulting from any deviation from these instructions is excluded from
warranty and liability for this product. Carry out other commissioning steps only if you have fully
understood the following contents.
Before commissioning and using the unit, carry out all the essential preliminary work and measures
concerning legal regulations and safety. These are described on the following pages of this
operation manual.
G E N E R A L I N F O R M A T I O N
!
!
Note
Indicates additional information on how to use the unit.
i
Description of marks and warning signs
The following warning signs are used in this document to identify the corresponding warning notes
which require particular attention by the user. The warning signs are defined as follows:

Page A - 5
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
D E S C R I P T I O N
Scope of Delivery
Compressors are provided in different equipped versions.
Versions
Filling pressure versions:
• PN 225 bar
• PN 330 bar
• PN 225 / 330 bar
Specifications
Options
• Auto start system
• 200 and 300 bar parallel filling pressures
• Phase monitoring c/w shut down at wrong
direction of rotation
• Ambient temperature monitoring
• Oil pressure gauge
• Intermediate pressure gauges
• Oil pressure monitoring c/w auto shut down
• Cylinder head temperature monitoring with
auto shut down
• Oil temperature display with auto shut down
• 1.7l filter housing
• Puracon filter monitoring (Auto shut down
also available)
• Remote Tab Control - RTC
• Additional high pressure outlet
• Additional high pressure outlet
• Power cable and plug
• Special voltages / frequencies on request
• Automatic condensate drain with pressure
free start/stop
• Automatic stop at final pressure
• Hour counter
• Operating panel with start/stop and
condensate test button, as well emergency
stop switch
• 2x Filling hose c/w filling valve
• Motor protection switch
• Pressure maintaining and non return valve
• All pistons c/w steel piston rings
• Low pressure oil pump and filter
• Oil- / Water separators in stainless steel
• Safety valves after each stage
• 3 x concentric suction/pressure valves
• Filling pressure to your choice
(200 or 300 bar)
• Connections to your choice (DIN 200 bar or
300 bar, CGA 200 bar or 300 bar and INT)
• Breathing air purification an accordance to EN
12021

Page A - 6
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
D E S C R I P T I O N
Technical Data
Technical Data LW SC-300 E LW SC-350 E
Capacity [l/min]: 300 350
Max. Operating Pressure [bar]: 350 350
RPM [min-1]: 1270 1495
Number of Pressure Stages: 3 3
Cylinder Bore 1st Stage [mm]: Ø 95 Ø 95
Cylinder Bore 2nd Stage [mm]: Ø 40 Ø 40
Cylinder Bore 3rd Stage [mm]: Ø 18 Ø 18
Medium: Compressed Air / Breathing Air
Intake Pressure: atmospheric
Oil Pressure [bar]: +0.6 to +4.0 +0.6 to +4.0
Oil Capacity [l]: 1.8 1.8
Intake Temperature [°C]: 0 < +45 0 < +45
Ambient Temperature [°C]: +5 < +45 +5 < +45
Cooling Air Volume [m³/h]: > 2250 > 2250
Voltage: 400 V / 3 phase / 50 Hz
Protection Class Drive Motor: IP 54 IP 54
Drive Power [kW]: 7.5 7.5
RPM Motor [min-1]: 2890 2890
Start: Star/Delta
Noise level from a distance of 1 m [dB(A)]: 83 83
Dimensions W x D x H [mm]: 1060 x 640 x 1000
Weight [kg]: approx. 240 approx. 240
Content Volume Filter housing [l]: 0.98 0.98

Page A - 7
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
Unit Assembly
D E S C R I P T I O N
No. Designation
1 Filling pressure gauge
2 Switchboard
3 Filling hoses (optional: without filling hoses)
4 Filling valves
1 2
4
3

Page A - 8
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
Switchboard
D E S C R I P T I O N
1 2
3 4 5
No. Designation
1 Emergency shut-off switch
2 Hour counter
3 ON button
4 OFF button
5 Drain test button
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels L&W Compresseur d'air
Manuels Compresseur d'air populaires d'autres marques

Campbell Hausfeld
Campbell Hausfeld RP3300 Guide de démarrage rapide

Ingersoll-Rand
Ingersoll-Rand UP6 20 HP Manuel utilisateur

Hitachi
Hitachi EC99S Manuel de l'opérateur

Parkside
Parkside PKO 270 A1 Manuel utilisateur

Sullair
Sullair 185 Manuel utilisateur

Clas Ohlson
Clas Ohlson QIE-ZTH-15 Manuel utilisateur