1General information..................................................................................3
1.1General safety information.................................................................................................................................................3
1.2Intended use and application restrictions....................................................................................................................3
1.3Storage and transportation................................................................................................................................................4
1.4Scope of documentation and reference to other documents .............................................................................4
1.5Technical customer support...............................................................................................................................................4
2Controls .........................................................................................................5
2.1Overview ....................................................................................................................................................................................5
2.2Measurement button............................................................................................................................................................5
2.3Dosing unit................................................................................................................................................................................5
2.3.1Dosing units available..................................................................................................................................................5
2.3.2Cover...................................................................................................................................................................................6
2.4Components on the underside.........................................................................................................................................6
2.4.1Illumination.......................................................................................................................................................................6
2.4.2Prism....................................................................................................................................................................................6
2.4.3Aperture.............................................................................................................................................................................7
2.4.4Dosing outlet ...................................................................................................................................................................7
3Filling cartridges for the pressurized dosing unit..........................8
4Carrying out a measurement ............................................................. 10
4.1Note for dosing and calibration.....................................................................................................................................10
4.2Connecting the MSA...........................................................................................................................................................10
4.3Creating a measurement in ADVANCE........................................................................................................................10
4.4Calibration of the drop volume......................................................................................................................................10
4.5Carrying out a measurement...........................................................................................................................................11
5Using the optional syringe dosing unit.......................................... 12
5.1Notes on reconfiguration..................................................................................................................................................12
5.2Changing the dosing unit .................................................................................................................................................12
5.3Filling the syringe dosing unit.........................................................................................................................................14
5.3.1Opening the cover.......................................................................................................................................................14
5.3.2Filling the syringe.........................................................................................................................................................15
5.3.3Fitting the syringe sleeve..........................................................................................................................................15

Contents page 2
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
5.3.4Removing the syringe sleeve ..................................................................................................................................15
6Cleaning...................................................................................................... 16
6.1Housing ....................................................................................................................................................................................16
6.2Underside, prism and illumination ................................................................................................................................16
6.3Valve ..........................................................................................................................................................................................16
6.4Needle guide for the optional syringe dosing unit................................................................................................17
Appendix......................................................................................................... 18
ITechnical data........................................................................................................................................................................18
IIComputer requirements ....................................................................................................................................................18
IIIProcedure if repairs should be necessary...................................................................................................................19
IVWarranty and caveat emptor...........................................................................................................................................20
VCopyright and right to make alterations ....................................................................................................................20

General information page 3
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
1General information
Dear KRÜSS GmbH Customer,
Thank you for having chosen our Mobile Surface Analyzer – MSA. This manual will help you with
the commissioning, operation and maintenance of the MSA.
This manual is subject to continuous quality control. You can download the latest version of
the manual from the customer download area on our website www.kruss.de.
1.1 General safety information
SPAC SP AC SPAC SPA C
The MSA may only be used by trained personnel.
SPAC SPA C SPAC SPAC
Wear protective goggles against chemicals when working with the MSA.
The MSA is not designed for working with liquids that are classified as toxic, corrosive,
explosive or radioactive.
SPAC SP AC SPAC SPA C
When carrying out measurements with hazardous substances the safety regulations and, if
available, information in the appropriate safety data sheets must be taken into account when
handling such substances.
SPAC SPA C SPAC SPAC
The controls of the MSA and a connected computer must not be operated when wearing
protective gloves, which have already been used for handling hazardous materials.
SPAC SPA C SPAC SPAC
Do not use the MSA if the unit is obviously damaged.
SPAC SPA C SPAC SPAC
1.2 Intended use and application restrictions
The MSA is only intended for measuring the contact angle of liquids on solid surfaces and
for determining the surface free energy of solids.
The intended use includes the exclusive use of accessories supplied by KRÜSS or substitutes
with an identical design if disposable accessories are being used.
Do not use the instrument in atmospheres containing dust, smoke or aerosols; these affect
the optical components of the instrument and could damage them.
The following temperature ranges apply for working with the MSA:
10°C to 40°C for operation
-10°C to 70°C for storage
Avoid contacting the optical components with sharp objects.

General information page 4
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
1.3 Storage and transportation
!If you intend to not use the instrument for a longer period of time or transport it longer
distances (i.e. by plane), remove the cartridges.
1.4 Scope of documentation and reference to other
documents
This handbook describes the manual operating steps for the MSA and the measurement of
surface free energy with distilled water and diiodomethane based on the standard measuring
template in the ADVANCE software. The modification of measurement parameters and all other
functions of ADVANCE are described in the software documentation.
SPAC SPA C SPAC SPAC
1.5 Technical customer support
If your KRÜSS product should not word as expected, please consult our technical customer
support. You can contact them at:
KRÜSS GmbH
Technical customer support
Tel: +49 040/514401-55
Fax: +49 040/514401-98
SPAC SP AC SPAC SPA C

Controls page 5
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
2Controls
2.1 Overview
2.2 Measurement button
Pressing the measurement button starts the automated sequence which is set up in the
ADVANCE software. In the standard configuration, the contact angles with water and
diiodomethane are measured simultaneously and the surface free energy is calculated.
Do not press the measurement button when the MSA is not positioned on a sample. The
pressurized dosing system ejects drops of the test liquids.
2.3 Dosing unit
2.3.1 Dosing units available
The MSA can be used with two different dosing units:
Standard: Pressurized dosing unit with two cartridges for the simultaneous dosing of
distilled water and diiodomethane
Option: Syringe dosing unit DO3910 for the dosing of other liquids (Chapter 5)
Dosing unit
cover
Measurement
button
Connecting
cable (USB)
Camera
(integral)
Underside with dosing
outlet and optics

Controls page 6
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
2.3.2 Cover
The cover is only opened for filling purposes. When the MSA is connected, the dosing unit is
prepared for filling by opening the cover:
Pressurized dosing unit (standard): the pressure is released.
Optional injection dosing unit: the plunger is moved to the top.
2.4 Components on the underside
2.4.1 Illumination
The illumination is divided into segments to enable two dispensed drops to be illuminated
separately. In the standard configuration, the illumination is optimized for two drops, each of
1 µL.
The illumination is switched on when the MSA is connected.
2.4.2 Prism
The prism deflects the light into the integral camera.
Prism
Illumination
(MSA connected)
Aperture
Dosing
outlet

Controls page 7
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
2.4.3 Aperture
The rotatable aperture prevents flat drops from being over-illuminated. As standard, it is set to
an angle of approximately 45° for drops of 1 µL with contact angles of 30° and above.
If necessary, adjust the aperture with the help of the Allen key provided to optimize the drop
image for flatter drops.
2.4.4 Dosing outlet
The drops emerge from the dosing outlet and come into contact with the sample between the
illumination unit and the prism.

Filling cartridges for the pressurized dosing unit page 8
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
3Filling cartridges for the pressurized dosing
unit
The pressurized dosing unit is used exclusively for water and diiodomethane.
1. Open the cover of the MSA. Remove the wing nut.
2. Remove the dosing cover. The cartridges are now accessible.
3. Remove the cartridge to be filled. To get an easier access to the cartridges there is a removal
tool included which is to be put underneath the lid of a cartridge.
!The transparent cartridge is intended for water, and the brown one for diiodomethane.
Do not transpose the cartridges or their positions in the dosing unit.
4. Fit a Luer adapter to the cartridge. Fill a disposable syringe with exactly 1 mL of the test
liquid.
Diiodomethane cartridge
Water cartridge

Filling cartridges for the pressurized dosing unit page 9
KRÜSS GmbH | Borsteler Chaussee 85 | 22453 Hamburg | Germany | www.kruss.de
5. Hold the cartridge with the Luer connection downwards. Fit the syringe. Press the test liquid
into the cartridge. In doing so, the plunger will be forced upwards.
6. Rotate the assembly so that the Luer outlet is at the top. Extract any remaining air with the
syringe. Remove the syringe and the Luer adapter.
7. Place the cartridge in the dosing unit. Repeat the filling process for the second cartridge if
necessary.
8. Fit the cover to the dosing unit. Tighten the nut by hand. Close the cover.
9. Operate the dosing unit to dispense drops onto a suitable surface until drops appear on
both sides (Chapter 4).
Syringe
Luer adapte
r
Plunge
r
Cartridge
Table des matières
Autres manuels kruss Instrument de mesure

kruss
kruss M5000 Manuel utilisateur

kruss
kruss BP50 Manuel utilisateur

kruss
kruss K11 MK3 Manuel utilisateur

kruss
kruss M3000 Manuel utilisateur

kruss
kruss M5000 Manuel utilisateur

kruss
kruss DR301-95 Manuel utilisateur

kruss
kruss DR201-95 Manuel utilisateur

kruss
kruss P3000 Manuel utilisateur

kruss
kruss DR101-60 Manuel utilisateur

kruss
kruss DSA100 Manuel utilisateur
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur