KOKEN LM-109MA Manuel utilisateur

Male
Catheterizationand
EnemaSimulator
(Strap-ontype)
LM-109MA
InstructionManual
ThankyouforpurchasingtheMaleCatheterizationandEnemaSimulator(Strap-ontype).
Pleasereadthisinstructionmanualcarefullytoensurecorrectuseoftheproduct,
andstoreitinasafeplaceforeasyaccess.
KOKENCO.,LTD.
1-4-14Koraku,Bunkyo-ku,Tokyo112-0004JAPAN
URL:http://www.kokenmpc.co.jp
E-mail:[email protected]
©2016-2020KOKENCO.,LTD.C-1-1025-1-01-06

1
Handling and Safety Precautions
These precautions should be strictly observed in order to ensure safe,
long-term use of the product.
The following precautions should be observed particularly strictly:
1. Thissimulatorismadetohavethesamefeelasthatofalivingbody.Unduehandlingmaycause
breakageofthesimulator.
2. Thismodelhasadistinctiveodorresultingfromthematerialsitismadefromhoweverisnot
harmfultothebodyorindicateanyproblemwithquality.Thisdistinctiveodorwillweakenover
time.Theproductisalsocoatedinbabypowderatthetimeofmanufactureandthesmellof
babypowdermayremainontheproduct.
3. Thesimulatorreproducestheresistanceofthebulbarurethra.
Wheninsertingthecatheter,ifthepenisisloweredtoananglelessthanabout60degrees,the
insertionofthecathetermaybedicult.Accordingly,pleaseholdthepenisatanangleofabout
60degrees.
4. Whenyoupracticecleaningordisinfectingofthepubicarea,pleaseusewater.Useofalcohol
maycausebreakageofthesimulator.
Useofcoloreddisinfectantliquidmaycausepigmenttobefixedtothesimulatorsothatthe
pigmentcannotberemoved.
5. Asforthelubricant,pleaseuseK-Ytmlubricatingjelly.PleasedonotuseK-Y®gel,asitmay
increasetheinsertionresistanceofthecatheter.
6. Pleasedonotuseoilylubricant(oliveoiletc.),alcohollubricant,andlubricantcontainingorganic
solvent.Thesemaycausebreakageofthesimulator.
7. Pleaseusecathetersof14Frand16Fr.
8. Pleasecheckthestateofthecatheterbeforeinsertingthecatheter.Pleasedonotuseacatheter
thatisdegradedordeformed.Suchacatheterisdiculttoinsert.
9.Wheninsertingthecatheter,pleaseapplythelubricanteachtime.
10.Ifitisdiculttoinsertthecatheter,pleaseincreasetheamountofthelubricanttobeapplied
oruseanothercatheter(firmsiliconecatheterorcatheterwiththinnerbaloonpartetc).The
simulatormaybreakifsuchacatheterisforcedtobeinserted.

2
11.Whenindwellingthecatheter,pleaseinatetheballoonafterinsertingthecatheterapartfrom
theballoonendportionbyadistanceequaltoorgreaterthan23cm.Indwellingofthecatheter
inanintermediateofthevalvecausesthevalveandthecathetertobebroken.
12.Iftheinsertionofthecatheterisrepeatedapluralityoftimes,watermayaccumulateinthe
urethralcanal.Ifthesimulatorisusedinsuchastate,watermayleakthroughtheurethralexit.
Pleaseslantthesimulatorsuitablytodrainthewater.
13. Afteruse,pleasewashthesimulatorandthecatheterwellwithwater.Ifthelubricantdriesand
hardens,itmayinterferewiththeuseofthesimulator.
14.Pleasecheckthestateofthevalveateveryuse.Ifthevalveisbroken,itmaycausealeakageof
water.
15.Oilcomponentsmaycomeoutofthegenitalskin.Afteruse,pleasedonotkeepthegenitalskin
attachedtothesimulator.Pleasewrapitincookingpaper,gauze,etc.,putitintoanattached
reclosablepolybag,andkeepit.Foradetailedstoragemethod,pleaserefertothewashingand
storagemethodsonpage14.
16.Applycommerciallyavailablebabypowdertoreducefrictionifyoumindstickinessofthegenital
skinorafteritiswashedwithwaterfollowinguse.
17.Pleasecheckthestateofthegenitalskineverythreeyearsasareference,andexchangeit
accordingly.
18.Pleasedonotplaceobjectsonthesimulator.Otherwise,thesimulatormaybedeformed.
19. Pleasedonotkeepthesimulatorincontactwithprintedmatter.Print,suchasletters,may
transfertothesimulatorandbexedthere.
20.Whenstoringthesimulator,pleaseselectaplacethatisnotsubjecttodirectsunlightand
ultravioletrays.
21.Thisproductisintendedforuseinstandardoperatingenvironments.Donotuseitinheavy
industrialsettings.
22.Thismodelusesurethanefoamforsomeofitsparts,andmaybesusceptibletodamagefrom
peststhatareattractedtourethanefoam(suchasinsectsintheantfamily).
Whenstoringthismodel,ensurethatthoroughmeasuresaretakentopreventpestdamage
beforestoring.Thecompanywillnotbeinvolvedwithorheldliableforpestdamagethatoccurs
duringstorage.
1.Thecontentsofthisinstructionmanualaresubjecttochangewithoutnotice.
2.Thisinstructionmanualmaynotbereproducedinpartorinitsentiretywithoutpermission.
3.Pleasecontactthemanufacturerintheeventthatanyerrorsoromissionsarefoundinthecontentsof
thisinstructionmanual.
4.Thisproductshouldbeusedonlyasdescribedinthisinstructionmanual.Inparticular,theproduct
shouldnotbeusedinanywaythatcontravenestheprecautionsnotedintheinstructionmanual.

3
Table of Contents
1. Outline and Features
2. Components and Conguration
3. Handling Method
4. Washing and Storage Methods
5. Specications
6. Replacement Parts (Sold Separately)

4
1. Outline and Features
Outline
Thesimulatorcanbemountedonahumanbodyoradollsothataseriesoftechniquesregarding
catheterizationandenemacanbepracticed.Thefeelofthepenisiscloselysimilartothatofaliving
bodypenis.Ifacatheterizationcatheterisappropriatelyinserted,urine(water)owsout.
Features
・Thesimulatorisofanactualsizebywhichacatheterizationandglycerineenemaforanadult
malecanbepracticed.
・Sincethesimulatorisofastrap-ontype,itcanbemountedonahumanbodyoramodeldoll
sothatthepracticecanbeperformed.
・Bymountingthesimulatoronahumanbody,thefeelingofapatientcanbesimulated.
Also,bymountingthesimulatoronasimulationpatient,techniquescanbepracticedwhile
communicatingwiththesimulationpatient.
・Sincesoftandstretchablematerialsareusedforthepubicarea,theappearanceandfeelare
realistictogivepresencewhenpracticing.
・Aseriesoftechniquesofcatheterizationsuchasdisinfectingofapubicarea,andinsertingand
removingofacathetercanbepracticed.
・Techniquessuchaspeelingoftheforeskin,disinfectingandcleaningcanbeperformed.
・Themotionofthepenisisalsoclosetothatofalivingbodypenis.Thesimulatoriscongured
suchthatitisdiculttoinsertthecatheterifthepenisisnotraisedappropriately.
・Theattachedglycerineenematorcanbeinsertedthroughtheanustotherectum.Thisenables
thepracticefortheglycerineenema.

5
2. Components and Conguration
1. Urethralpart
2. MaleGenitalskin
3. BladderValve(Male/Female)
4. O-ring
5. Strap-ontypeframe
6. Bladdertube
7. Strap-ontyperectumconnecting
connector
8. Bagforirrigator
9. Tubeforirrigator
10.Draintube
11. Glycerineenemator
Storagebag
Instructionsmanual(thispamphlet)

6
3. Handling Method
3-1AssemblingofSimulator
1. Pleaseconnectthebagforirrigatortothebladdertube,andputwaterintothebagfor
irrigator.Pleaseopenaclamp,llthebladdertubewithwater,closetheclamp,andattach
thebladdervalvetothebagforirrigator.
2.Pleaseapplylubricanttothedistalendoftheglansandinsertitintothegenitalskin.
Pleasecheckthattheglansisnottwistedandthenxtheurethralpartandthegenitalskin
withhookandloopfasteners.
Checkwhether
ornottheglans
istwisted.

7
3.Pleaseinserttheurethralpartofthegenitalskinintothestrap-ontypeframe.
4.Pleaseinsertthestrap-ontyperectumconnectingconnectorintothestrap-ontypeframe,
andputtheanalportionofthegenitalskinonthestrap-ontyperectumconnecting
connector.Aftertheconnectorisinserteddeepintotheanalportion,pleasetandxthe
positionofthegenitalskintothestrap-ontypeframe.
5.PleaseinserttheO-ringintotheconnectoroftheurethralpart,andconnectittothebladder
tube.

8
6.Pleaseconnectthestrap-ontyperectumconnectingconnectortothedraintube.
3-2WearingMethod
1.Pleaseremovethefrontbeltandrearbeltfromthewaistbelt.
2.Pleasewearthewaistbeltandadjusttheadjusteraccordingtowaistsize.

9
3.Pleasepassthefrontbeltthroughthewaistbelt,andtandxthepositionofthepubicarea
withhookandloopfasteners.
4.Pleasepasstherearbeltthroughthewaistbelt,andxitwithhookandloopfastenerssuch
thatthebeltsdonotcomeloose.
5.Whenperforminganenematechnique,pleaseremovethefrontbeltonce,tthepositionof
theanustothebody,andadjustthelengthoftherearbeltrst.
CaseofCatheterization
CaseofEnema
Table des matières
Autres manuels KOKEN Équipement pédagogique
Manuels Équipement pédagogique populaires d'autres marques

fischertechnik
fischertechnik STEM Coding Pro Manuel utilisateur

Experia
Experia IRiS Light Wand Manuel utilisateur

Pitsco Education
Pitsco Education FLO Manuel utilisateur

Sphero
Sphero RVR RV01 Manuel utilisateur

Limbs & Things
Limbs & Things 60905 Manuel utilisateur

JP
JP TURN Connect T101 Manuel utilisateur

TruCorp
TruCorp AirSim Advance Manuel utilisateur

LeapFrog
LeapFrog Mr. Pencil's Scribble, Write & Read Manuel utilisateur

ScienTECH
ScienTECH 2261 Manuel utilisateur

Rompa
Rompa 20019 Manuel utilisateur

Duinotech
Duinotech XC4322 Manuel utilisateur

Enabling Devices
Enabling Devices Spinning Light Show Manuel utilisateur






