Kemppi DIGITAL CONNECTIVITY MODULE Manuel utilisateur

Digital Connectivity Module (DCM)
Operating manual - EN
DIGITAL CONNECTIVITY MODULE (DCM)
Operating manual
© Kemppi 11921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
CONTENTS
1. General 3
1.1 Equipment description 5
2. Installation 7
2.1 Mounting on equipment 8
2.2 Connecting cables 11
2.3 Installing WeldEye App 12
2.4 Android operating system settings 15
3. Operation 16
3.1 Pairing with mobile device 17
3.2 Settings 18
3.3 Using WeldEye App 21
3.4 During welding 28
3.5 Completing welding tasks with WeldEye App 29
3.6 Synchronizing welding data 30
3.7 Resetting 31
3.8 Disconnecting 32
3.9 Updating DCM 33
4. Technical data 34
5. Ordering codes 35
© Kemppi 21921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
1. GENERAL
Kemppi's Digital Connectivity Module (DCM) is a small single-board computer connected directly to the welding power
source or wire feeder. Together with WeldEye App, it collects and synchronizes welding data and adds tools to the work-
flow management, for example, in the form of work orders and welding procedure specifications (WPS). The welding
data collected with DCM is synchronized with the WeldEye welding management software cloud via WeldEye App.
DCM uses wireless Bluetooth technology for communicating with the mobile device.
DCM and WeldEye App are a new alternative for Kemppi's Smart Reader device. It is compatible with the following
Kemppi welding equipment:
•MasterMig 353, 355
•X5 FastMig
•FastMig KMS
•FastMig Pulse
•FastMig M
•FastMig X
•Kemparc
•Kemparc Pulse
•A7 MIG Welder.
DCM also supports non-Kemppi welding equipment through ARC Euro Adapter -CV, ARC Saw Adapter and ARC Univer-
sal Adapter -CV/-TIG.
Important notes
Read the instructions through carefully. For your own safety, and that of your working environment, pay particular atten-
tion to the safety instructions delivered with the equipment.
Items in the manual that require particular attention in order to minimize damage and harm are indicated with the
below symbols. Read these sections carefully and follow their instructions.
Note: Gives the user a useful piece of information.
Caution: Describes a situation that may result in damage to the equipment or system.
Warning: Describes a potentially dangerous situation. If not avoided, it will result in personal damage or fatal injury.
© Kemppi 31921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
DISCLAIMER
While every effort has been made to ensure that the information contained in this guide is accurate and com-
plete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the spe-
cification of the product described at any time without prior notice. Do not copy, record, reproduce or transmit
the contents of this guide without prior permission from Kemppi.
© Kemppi 41921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
1.1 Equipment description
1. Function button
2. 3 LED indicators
3. CAN connection (5-pin, M12 bus connector)
4. USB connector *
5. Power connector *
6. Ethernet connector *
7. Mounting tape.
*Not needed for normal operation. DCM is powered through the CAN connection.
LEDs explained
a. Red / yellow / green:Additional notification light. (A)
b. Green:Lit when the power is on. (B)
c. Blue:Blinks infrequently when ready and available, blinks more frequently when in "beacon mode", is lit con-
tinuously when a mobile device with the WeldEye App is connected. (C)
Additional requirements
•Bluetooth-enabled mobile device running Android 6.0 (or newer)and WeldEye App
•Internet connection available for the mobile device running WeldEye App
•Kemppi's WeldEye welding management software account.
© Kemppi 51921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
EQUIPMENT IDENTIFICATION
Serial number
Serial number of the device is marked on the rating plate or in another distinctive location on the device.
Quick Response (QR) code
The serial number and other device-related identification information may also be saved in the form of a QR
code (or a barcode) on the device. Such code can be read by a smartphone camera or with a dedicated code
reader device providing fast access to the device-specific information.
© Kemppi 61921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
2. INSTALLATION
Do not power on the equipment before the installation is complete.
"Mounting on equipment" on the next page
"Connecting cables" on page11
"Installing WeldEye App" on page12
"Android operating system settings" on page15
Before installation
Check the contents of the packages and make sure the parts are not damaged.
© Kemppi 71921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
2.1 Mounting on equipment
The DCM device can be fixed on the side of a power source or a wire feeder either with the factory-fitted mounting tape
or with an optional DIN rail.
The mounting tape can be used on any clean and suitable surface. The mounting tape counterparts are attached
together on delivery.
Do not detach the mounting tape counterpart from the DCM device before fixing. This way the mounting tape coun-
terparts are positioned correctly on the installation surface.
Install the DCM device the connectors facing down. This also prevents e.g. dust and impurities from getting into the
connectors.
Fixing with mounting tape
1. Clean the installation surface (where the DCM device is to be fixed).
2. Remove the cover wrappings from the mounting tape counterpart to reveal the adhesive surface. Leave the mount-
ing tape counterparts still attached.
3. Press the DCM device firmly against the installation surface so that the glue sticks.
© Kemppi 81921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
4. Let the mounting tape's adhesive cure for 30 minutes.
5. Due to the velcro-type mounting tapes, it is now possible to detach and attach the DCM device if needed.
Mounting on DIN rail (optional)
Note that the rail installation typically requires drilling fixing holes on the fixing surface for the rail itself. This is not
covered by this instruction.
The rear of the DCM box has a groove for the standard DIN rail fixing:
© Kemppi 91921370 / 2212

Digital Connectivity Module (DCM)
Operating manual - EN
© Kemppi 10 1921370 / 2212
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur