InnoTorc GmbH Instruction Manual EMA Page 6
Setting the switch off torque in torque mode:
Switch on the tool:
The EMAX torque tool is switched on by pressing the button . The main menu is shown in figure 1.
With the two buttons and , the individual menu items can be selected. Select the “Start Torque”
function. The selection is accepted by pressing the button .
Select Gear:
The choice of gear stage (power = gear 1, fast = gear 2) is selected by using the rotary switch on the
side of the tool. Care should be taken to ensure that the rotary switch is in the respective end position!
The selected gear stage is shown in the display. The torque ranges available for gears 1 and 2 are
each adjusted (gear 1 = full torque range, gear 2 = reduced torque range).
Select Torque:
The desired switch off torque can be specified in stages (figure 2). With the buttons – and + the
switch-off torque can be selected in fixed steps. The selection is done with the button . The display
changes to "Ready".
You can return to the higher-level menu by briefly pressing the button . Similarly, one of the three
buttons can be pressed to return to the higher-level menu.
Ready to start:
After torque selection, the tool is ready for operation (figure 3). The tool can now be started with the
rocker button in the handle. Pressing the lower half of the rocker starts the tool in clockwise rotation,
the upper half starts the tool in counter clockwise rotation. Releasing the rocker, or when the set
torque has been reached, the tool stops.
You can return to the higher-level menu by briefly pressing the button . Similarly, one of the three
buttons can be pressed to return to the higher-level menu.
Esc
Esc
Esc
Fig. 2: Select switch off
Fig. 1: Main menu Fig. 3: Tool is ready for