IKUSI HTI-404 Manuel utilisateur

Web Interface guide
HTI-404
REF. 3864

2
Web Interface guide HTI-404

3
Web Interface guide HTI-404
Index
1. INTRODUCTION ....................................................................................................................................4
1.1 General safety instructions ...........................................................................................4
1.2 Installation enviroment recommendations ............................................................. 5
1.3 Description of the module HTI-404 .............................................................................5
2. HEADEND CONNECTION .................................................................................................................. 6
3. COMMUNICATION WITH THE HEADEND ..................................................................................... 6
4. WEB INTERFACE ..................................................................................................................................7
4.1 Headend .............................................................................................................................. 7
4.1.1 Overview...............................................................................................................7
4.1.1.1 Registering process ............................................................................9
4.1.1.2 Reboot and reset................................................................................11
4.1.2 General configuration.....................................................................................11
4.1.2.1 Site identification................................................................................11
4.1.2.2 Password..............................................................................................11
4.1.2.3 Internet access....................................................................................12
4.1.2.4 Country..................................................................................................12
4.1.2.5 LNB and multiswitch.........................................................................12
4.1.2.6 Autoscan DTT inputs .........................................................................13
4.1.2.7 Configuration backup........................................................................14
4.1.3 Headend DVB network ...................................................................................14
4.1.3.1 Output network configuration ........................................................15
4.1.3.2 Modules in network...........................................................................16
4.1.4 Installation report ............................................................................................16
4.2 Modules configuration...................................................................................................17
4.2.1 Inputs...................................................................................................................17
4.2.2 Outputs................................................................................................................20
4.3 RF services configuration ............................................................................................22
4.4 Firmware management................................................................................................29
4.5 Language...........................................................................................................................30
4.6 Exit ......................................................................................................................................30
5. EQUIPMENT RECYCLING .................................................................................................................31

4
Web Interface guide HTI-404
1. INTRODUCTION
This document explains how to perform the installation of a headend based on HTI-404 modules.
The document describes how the headend is configured. For that, initially the physical mounting is descri-
bed. After that, it explains how to connect the user pc to the headend through IKUSI HEADEND DISCOVERY
application. Finally, all the menu options of the web interface are described.
To ensure the correct use and installation of the headend, it is necessary to read the user manuals and the
installation manuals of the modules included in their own packages.
1.1 General safety instructions
Read all of this user manual carefully before plugging in the unit.
Always have these instructions to hand during installation.
Follow all of the instructions and safety notices regarding unit handling.
Danger of death or injury
This safety notice indicates a possible danger for the life and health of people. Not following
these instructions may lead to serious consequences to health and may even cause fatal
injuries.
Do not install the unit during an electrical storm. This could lead to electrostatic discharge from
lightning.
Do not open the unit. There is a risk of electrostatic discharge.
Risk of damage to the unit
This safety notice indicates a possible dangerous situation. Not following these instructions
may lead to the unit being damaged.
The unit must be appropriately ventilated. Install the unit in a dust-free location. Do not place
the unit in a location where the ventilation slots are covered or blocked. Install the unit in a
location with at least 20 cm around it free of other objects.
Do not expose the unit to rain or moisture. Install the equipment in a dry location with no
infiltration or condensation of water. Should a liquid enter the unit, disconnect it immediately
from the mains.
Keep the unit away from flammable objects, candles and anything that may cause a fire.
Connect the unit to an easily accessible power socket. In the event of an emergency, it will then
be possible to quickly unplug the unit.
Do not expose the unit to sources of heat (sun, heating, etc.).
Handling the inside of the unit is forbidden
This notice forbids any work that may aect the working order of the unit or its warranty
Do not dispose of as urban waste
This type of notice indicates that the unit must not be disposed of as unselected urban waste.
NOTE: This type of notice is a note containing applicable advice and useful information for optimum use of the unit.
DANGER
ATTENTION

5
Web Interface guide HTI-404
1.2 Installation enviroment recommendations
The headend is for indoor use only.
Do not plug in the headend in moist rooms.
Never operate the headend immediately after moving it from a cold location to a hot location. When the
device is exposed to such a change in temperature, moisture may condense on the crucial internal parts.
The device must have sucient ventilation and may not be covered.
Protect the device against direct sunlight, heat, intense temperature fluctuations and moisture. Do not place
the device in the vicinity of heaters or air conditioners.
Do not allow liquids to enter into the device. Turn o the device and disconnect it from the main supply if
liquids or foreign substances end up inside the device.
If the device gets too hot or emits smoke, shut it down immediately and unplug the power cable. Arrange
for your device to be investigated by a technical service centre.
Under the following conditions, a layer of moisture can appear inside the device which can lead to mal-
functions:
if the device is moved from a cold to a warm area;
after a cold room is heated;
when this device is placed in a damp room.
The device should not be used in a very dusty or saline environment. Dust or salt particles and other foreign
objects may damage the device.
Do not expose the device to extreme vibrations. It may damage the internal components.
1.3 Description of the module HTI-404
PSU-150
STATUS
OUTPUT TEST
OUTPUT
INPUT
INPUT TEST
EXT INPUT
Gain 6 dB
-30 dB
-20 dB
STATUS
HTA-125
GAIN
DVB RF IN
DVB RF OUT
STATUS
HTI-404
1
2
3
4
DVB RF IN
DVB RF OUT
STATUS
HTI-404
1
2
3
4
DVB RF IN
DVB RF OUT
STATUS
HTI-404
1
2
3
4
MSS-0512
Ref. 3654
Stand Alone Multiswitch (5 in-12 out)
FREQUENCY RANGE
SAT: 950-2300 MHz
TERR: 5-862 MHz
Input
BACK-500
USB-300
Master module
HTA-125
Router
PSU-150
Slot Nº2
USB-ethernet adapter
for remote or local configuration
1
2
3
4
DVB RF IN
DVB RF OUT
STATUS
HTI-404
1
2
3
4
1 Input (DVB-T/T2/S/S2/C)
2 Control LED
3 Management port (USB)
4 DVB-T/DVB-C output coupling loop

6
Web Interface guide HTI-404
2. HEADEND CONNECTION
The instructions for connecting the headend are described in detail in the guide that is provided with the
HTI module. Also, that guide can be downloaded from our web page www.ikusi.tv.
Briefly, the steps to follow are:
Insert the HTI modules and the PSU-150 power supply in the BACK-500 base-plate. One of the HTI modules
must be inserted in the slot 2 of the base-plate (master module).
Connect the dierent cables from the multiswitch to the module inputs.
Connect the pc to the USB port of the master module, located in the slot 2 of the base-plate, with a
USB-ethernet adapter.
NOTE: It is recommended to use USB-ethernet adapters based on AX88179 or AX88772 chipsets
3. COMMUNICATION WITH THE HEADEND
HTI is configured through a web page generated by the own headend. Use IKUSI HEADEND DISCOVERY application to
access this web page without modifying manually the network configuration of your pc. You can download the IKUSI
HEADEND DISCOVERY aplication from www.ikusi.tv web page.
NOTE: You must use IKUSI HEADEND DISCOVERY version 1.8.5 or higher
Open IKUSI HEADEND DISCOVERY application (the network card IPV6 protocol will be automatically enabled or
permission will be requested to do so).

7
Web Interface guide HTI-404
The window will show the name of the connected master module. Push Configure button and the web
browser of the PC will open automatically, showing the access page of the headend.
NOTE: HTI web interface uses https protocol. It is likely that your browser doesn’t recognize the security
certificate generated by the HTI. To continue configuring the module without problems, add the security
exception requested by your browser in a permanent way.
NOTE: It is recommended to use Mozilla Firefox or Google Chrome as browser.
By default, the language of the web interface is the same than the one used by the browser. If you want to
change it, choose in icon the flag related with the desired language.
Enter the folowing data, User: Admin Password: admin. Push Submit button. The main screen of the
configuration interface will open, from where you can configure the headend, as described in the next
section.
4. WEB INTERFACE
The web interface of the HTI allows to configure the headend, as well as to show status information of the
modules. The following sections describe each of the menu options available.
4.1 Headend
Headend menu, through a series of submenus, allows to display status information and to configure the
global parameters.
4.1.1 Overview
It is the menu that appears by default when entering the headend. The user can access this menu at any
time. To do this, go to Headend Overview. A screen as the following one will be displayed:

8
Web Interface guide HTI-404
This screen shows the whole headend schematically. The essential information of each module inserted
in the base-plate is displayed. The master module always corresponds with the module inserted in slot 2,
and it appears in white on black background. The remaining modules appear on white background.
When selecting a specific module, a window with status information and alarms in detail will open.

9
Web Interface guide HTI-404
In addition, through a series of buttons you can perform the following actions:
To register a module.
To unregister a module.
To clone settings from an old module to a new one.
To reboot a module.
To reset a module with its default settings.
To reset all modules of a headend, loading their default settings.
4.1.1.1 Registering process
The headend only allows to configure those modules that have been registered previously. The unregiste-
red equipments are shown in yellow on white background. By default, no module except the one inserted
in slot 2 (master slot) is registered. To register a module that has been detected by the master module
simply push Add button of that module. The background color change to white indicating that the module
has been properly registered.
Repeat the registration process with all modules you want to include in the headend.
If, for any reason, you want to unregister a module of the headend, you must push the Delete button. The
module will be displayed in yellow background, indicating that has been unregistered correctly.

10
Web Interface guide HTI-404
The registration process is dierent if it is the result of replacing a module (for example, due to failure).
In that case, when placing a new module in the position of one that had been already registered by the
headend, the user can choose between to add it without modifying the configuration of the module or to
copy the configuration of the module that was previously registered in that slot. In the following example,
starting from the previous headend with 3 HTIs, all registered, the HTI of slot 4 has been replaced with a
new HTI:
A module with two possible configurations is displayed: one in grey background, corresponding to the
previous module that was already registered in the headend, and another one in yellow background,
corresponding to the configuration of the new module pending registration.
If you want to copy the settings from the previous module, push Clone button. If, instead, you only want
to register the new module without copying the previous configuration, push Add button. In both cases, as
result a screen will be displayed where the module appears as registered.
Table des matières
Autres manuels IKUSI Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur
















