ICP DAS USA DL-110S-E Manuel utilisateur

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 1 -
DL-100S-E/DL-101S-E
/DL-110S-E/DL-120-E
Illumination/Temperature/Humidity/Dew Point
Data Logger User Manual
Version: 1.2.0
Date: Jun 2023

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 2 -
Warranty
All products manufactured by ICP DAS are warranted against defective materials for a
period of one year from the date of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages consequent to the use of this product.
ICP DAS reserves the right to change this manual at any time without notice. The
information furnished by ICP DAS is believed to be accurate and reliable. However, no
responsibility is assumed by ICP DAS for its use, nor for any infringements of patents or
other rights of third parties resulting from its use.
Copyright
Copyright © 2018 by ICP DAS. All rights are reserved.
Contact Us
If you have any questions, feel free to contact us via email at:

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 3 -
Contents
1. Introduction................................................................................................................4
2. Hardware ...................................................................................................................7
2.1 Specifications....................................................................................................7
2.2 Appearance.......................................................................................................9
2.3 Dimensions (unit: mm)....................................................................................14
2.4 Cabling for Power and Network ......................................................................15
3. Configuration via Web Browser................................................................................17
3.1 Search the DL-100S-E series module logger..................................................17
3.2 Logging into the DL-100S-E............................................................................18
3.3 Home..............................................................................................................19
3.4 Network...........................................................................................................20
3.5 MQTT..............................................................................................................22
3.6 I/O Settings.....................................................................................................25
3.7 Filter IP ...........................................................................................................29
3.8 Monitor............................................................................................................30
3.9 Change Password...........................................................................................30
3.10 Logout...........................................................................................................31
4. Configuration via RS-485(DL-110S-E / DL-120-E Only)...........................................32
4.1. Building the RS-485 Connection....................................................................32
4.2. AI tab..............................................................................................................36
4.3 Logger Configuration ......................................................................................37
5. Monitoring via Mobile Devices .................................................................................38
6. Utility to Get/Manage Data Log................................................................................39
7. FAQ..........................................................................................................................50
Q1: How to set theAccessible IP?........................................................................50
Q2: How to delete the Accessible IP settings?......................................................50
Q3: How to clear the data logged in a DL-100S-E module? .................................51
Q4: How to download firmware into a DL-100S-E module?..................................51
AppendixA: ModbusMasterToolPC..............................................................................55
Appendix B: Modbus Address Table.............................................................................58
B-1. DL-100S-E Modbus Address Mappings (Base 1)..........................................58
B-2. DL-101S-E Modbus Address Mappings (Base 1)..........................................61
B-3. DL-110S-E Modbus Address Mappings (Base 1)..........................................65
B-4. DL-120-E Modbus Address Mappings (Base 1) ............................................69
Revision History...........................................................................................................73

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 4 -
1. Introduction
The DL-100S-E series are Data Logger devices that can be used to record illumination,
temperature, humidity and dew point data, together with date and time stamp
information. Up to 600,000 downloadable records can be stored. Real-time data can be
accessed from the DL-100S-E series device from anywhere and at any time using the
free Windows software, the iOS App or the Android App, as long as they are connected
to the same local network as the Data Logger. The DL-100S-E series module supports
popular industrial protocols such as Modbus TCP, as well as the emerging
machine-to-machine (M2M)/IoT (Internet of Things) connectivity protocol – MQTT. The
DL-100S-E Series Data Logger can be connected using a variety of communication
interfaces, including Ethernet and PoE, meaning that the device can be easily
integrated into existing HMI or SCADA systems, and are easy to maintain in a
distributed control system.
Characteristics
Illumination Measurement Range: 0 to 100,000 Lux (DL-110S-E / DL-120-E Only)
Temperature Measurement Ranges: -20 to +60°C and 0 to 100% RH
LCD Display Shows Temperature, Humidity, Relative Humidity, Date and Time
( DL-100S-E / DL-101S-E Only)
Able to store up to 600,000 records with date and time stamps
Free Software Utility, iOS APP and Android App Included
Supports the Modbus TCP and MQTT protocols
Includes redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC input
( DL-101S-E / DL-110S-E / DL-120-E Only)
Relay Output for Alarm Devices or IAQ Device Control (DL-101S-E
Only)
Supports Web Configuration and Firmware Update via Ethernet
IP 66 Protection Approval (DL-100S-E / DL-101S-E Only)
IP 67 Protection Approval (DL-110S-E / DL-120-E Only)
DIN-Rail or Wall Mounted

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 5 -
Features
Built-in Web Server
With the built-in Web server, users can easily log in to the DL-100S-E series
module via a standard web browser to monitor the data and configure the settings
without install any software in the terminal.
Get Real-time Data Anywhere and Anytime
iAir App for iOS or Android Phones or Tablets is free and easy to install, it can
obtain the real-time data from DL-100S-E series module over a Wi-Fi network
anytime and anywhere. The iAir App can link to the DL-100S-E series modules by
specifying IP addresses or by searching all the modules connected to the same
Ethernet segment.
Data Logging Software
The iAir Utility can be used to configure a module and monitor real-time data, as
well as display the run chart, log alarm events, or group DL-100S-E series module
so that the status of distribution groups can be viewed and managed. The utility
also allows the log data to be downloaded and exported to a .CSV file that can then
be imported into any industry-standard software or spreadsheet for analysis.

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 6 -
Easy integration with SCADA software
Modbus is one of the most popular protocols used in the industrial world.
Supporting traditional serial protocols of Ethernet protocols allow the DL-100S-E
series module well-integrated into the HMI/SCADAsystems.
Easy Wiring
Support for Ethernet and Power over Ethernet (PoE) interfaces for users to choose
the appropriate one to meet the field requirements.
Power over Ethernet (PoE)
The DL-100S-E series module features true IEEE802.3af-compliant (classification,
Class 1) PoE technology that allows both power and data to be carried over a
single Ethernet cable. PoE provides a unified power system, as well as backup
provisions for critical building functions, without any additional cables, outlets or
connections. It can reduce the power supply wiring and maintenance costs, and
improve system scalability.
Support for MQTT protocol
MQTT is a protocol designed for the efficient exchange of real-time data with sensor
and mobile devices. It runs over TCP/IP and is in widest use on the
"machine-to-machine" (M2M) and "Internet of Things" applications today

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 7 -
2. Hardware
2.1 Specifications
Model DL-100S-E DL-101S-E
DL-110S-E DL-120-E
Illumination
Measurement
Range - 0 to 100,000 Lux
Resolution - 1 Lux
Accuracy - ±5%
Response Time - 1 second
Temperature Measurement
Range -20 to +60°C (-31 to +176˚F) -
Resolution 0.1°C -
Accuracy Typical: ±0.4°C; refer to figure 2 -
Relative Humidity Measurement
Range 0 to 100% RH -
Resolution 0.1% RH -
Accuracy Typical: ±3% RH @ 20 ~ 80% RH;
refer to figure 1 -
LCD LED Display
LCD Information
Displayed
Temperature (°C and °F),
Humidity (RH), Relative,
Humidity, Date and Time -
PWR System indicator (Green)
Link Link/Act indicator (Green)
PoE PoE indicator (Red)
Software
Built-in Web Server Yes
Communication
RS-485 Port - Baud Rate = 1200 ~ 115200 bps
Ethernet Port
10/100 Base-TX with Auto MDI/MDI-X
Protocol, Modbus TCP and MQTT DCON, Modbus RTU Modbus TCP
and MQTT
Security Password and IP Filter
Dual Watchdog Yes, Module (2.3 seconds), Communication (Programmable)

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 8 -
System
Real Time Clock Yes
Data Logger Yes, 600,000 Records
PhotoMos Relay Output
- Form A×2,
SPST 100 VDC
-
Interface Ethernet/PoE RS-485/Ethernet/PoE
Electrical
Powered via Terminal - +12 to +48 VDC
Powered via PoE IEEE 802.3af, Class 1 (require a PoE switch or injector)
Power
ConsumptionPoE 0.7 W (Max.) 0.7 W (Max.)
1.2 W (Max.)
Non-PoE - 0.6 W (Max.)
1.1 W (Max.)
Mechanical
Dimensions (W x L x H)
92 mm x 157 mm x 56 mm 100 mm x 157
mm
x 67 mm 100 mm x 117
mm x 67 mm
Waterproof Level IP66 IP67
Installation DIN-Rail or Wall mounted
Environment
Operating Temperature
-20 to +60°C
Storage Temperature -30 to +80°C
Humidity 5 to 95% RH, Non-condensing

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 9 -
2.2 Appearance

DL-100S-E / DL-101S-E / DL-110S-E / DL-120-E User Manual Version 1.2.0 Jun 2023 - 10 -
LED Indicators
The three LED indicators from left to right are:
PWR: green for normal operation.
Link: green for the Ethernet linked.
PoE: red for powered via PoE
DIP Switch
PoE/non-PoE Ethernet port
The Ethernet port can be used to connect to either a PoE switch or a non-PoE switch.
Installing a waterproof attachment on an RJ45 connector.
The DL-100S-E series module is equipped with an RJ-45 waterproof connector that
ensures the device is able to withstand potential contaminants in dusty environments.
IP67 RJ45 Plug (4SASO-0001)
The functions are printed on the top beside the
SW1 DIP switch. All the 4 dip switches need be
turned to the off position for normal operation.
1. Reserved
2. FW Update: ON for updating firmware.
3. Reserved
4. INIT: ON for using the factory default settings
for communication
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels ICP DAS USA Enregistreur de données

ICP DAS USA
ICP DAS USA PIR-23-WF Series Manuel utilisateur

ICP DAS USA
ICP DAS USA M-7026 Manuel utilisateur

ICP DAS USA
ICP DAS USA CL-201-WF Manuel utilisateur

ICP DAS USA
ICP DAS USA DL-1 S-WF Series Manuel utilisateur

ICP DAS USA
ICP DAS USA MDC-211-WF Manuel utilisateur

ICP DAS USA
ICP DAS USA DL-300-WF Series Manuel utilisateur

ICP DAS USA
ICP DAS USA PET-AR400 Manuel utilisateur

ICP DAS USA
ICP DAS USA ET-7002 Manuel utilisateur

ICP DAS USA
ICP DAS USA ET-7053 Manuel utilisateur

ICP DAS USA
ICP DAS USA DL-100S-E Manuel utilisateur