Table of Contents
Change log ....................................................................................................................... 3
Introduction ....................................................................................................................... 4
Product Overview .............................................................................................................. 5
General Features and Characteristics ........................................................................ 5
Physical Description .................................................................................................. 5
Configuring and managing the i6800 ................................................................................. 8
Web interface general overview ................................................................................. 8
Logging in to the web interface ................................................................................ 10
Viewing device status information ............................................................................ 11
Managing the LAN and Wi-Fi settings ...................................................................... 18
Using network diagnostic tools ................................................................................ 23
Changing administrator settings ............................................................................... 26
Managing services .................................................................................................. 28

3
Change log
Date Version Reason for a change Author

4
Introduction
The Icotera i6800 is a customer premises equipment designed for triple play services, dedicated
to FTTH (Fiber To The Home) network in P2P (point-to-point) architecture.
The i6800 integrates Ethernet-based data transmission with Layer 3-4 functionality, voice (IP
telephony), wireless 2.4 GHz 802.1b/g/n as well as 5 Ghz 802.11a/n/ac transmission, and CATV.
This device features a powerful dual core architecture, where all processor-intensive tasks are
handled by a dedicated core, leaving one core available for other immediate tasks. This explicitly
means that the system is still responsive, even while doing VoIP, gigabit routing of IPv4/IPv6 with
NAT (IPv4) or bridging wirespeed.
Two-channel SIP VoIP with alaw/ulaw fax is supported. Among other supported features local
tones and fast dial are included.
The Icotera i6800 provides a wide transparent bandwidth to support CATV analog channels or a
combination of analog and digital channels including HDTV broadcast.

5
Product Overview
This chapter provides a comprehensive overview of the i6800 components, features and
characteristics.
General Features and Characteristics
This section presents a list of features and characteristics of the Icotera i6800 related to its
hardware, software and environment of operation.
Features
• 802.11b/g/n WiFi
• 802.11ac WiFi
• 2 SIP VoIP ports
• Layer 2 - 7 QoS
• Layer 2 - 7 filters
• Customer web interface
• Full band CATV (optional)
• CATV filters (optional)
• USB 2.0 (providing up to 500mA)
• USB 3.0 (providing up to 500mA)
Uplink Interface
• Dual speed optical uplink with auto detection
Downlink Interfaces
• 4 x 10/100/1000 RJ45 ports
• Auto-negotiation for speed and duplex
• Auto MDI/MDX
Performance
• Gigabit routing with NAT and bridging
Power and Environmental Specifications
• DC12V input
• Power consumption (max): 12 watt
• Operating temperature: 0 – 50°C
• Storage temperature: -15 – 55°C
• Humidity: 10% – 90%
Physical Description
This section describes the physical components of the i6800, i.e. connectors, LEDs and buttons.

Product Overview
6
Front Panel
TheIcoterai6800frontpanel,showninthefollowingfigure,containsthepowerport,on/offswitch,
reset button, connectors and LAN status LEDs. All these items are described in subsequent
topics of this section.
Figure 1. The Icotera i6800 front panel
Status LEDs
There are two types of the Icotera i6800 status LEDs: LAN port LEDs and the LEDs on the LED
panel that is located between LAN and POTS ports.
Figure 2. The Icotera i6800 status LEDs
LAN Port LEDs LED Panel
Link
Status
Link
Activity
WAN
1
2
WiFi CATV
The following table shows the status LEDs descriptions for the Icotera i6800.
Table 1. The Icotera i6800 status LEDs descriptions
LED Type Type Colour State Description
On Communications link established
Blinking Network activity on the corresponding port
Link Activity LAN port
activity Green
Off Bad connection no connection to this port
On Corresponding port linked and operating at 1 Gb/sLink Status LAN port
status Yellow
Off Corresponding port set to operate at 10/100 Mb/s
N/A Off Power down
Blinking fast Obtaining IP address
Blinking slow Auto detection
Green
Solid IP connection established
Blinking slow Management or other interface lease fail (depends on
LEDs configuration)
WAN WAN port
activity
Red
Solid No signal
N/A Off Line disabled
Blinking fast Call in progress
Blinking slow Off-hook
Green
Solid Line registered
1
/
2
VoIP
registration
status/Hook
status
Red Solid Line registration error

Product Overview
7
LED Type Type Colour State Description
N/A Off WiFi not configured, disabled or not in use
Green/
Orange Blinking WiFi 5 GHz detecting radar (blinks for 60 secs;
for channels 120, 124, 128, and 132 blinks for 10
minutes). NOTE: For some production batches radar
detecting may by signalled by WiFi LED blinking red.
In this case red color does not signal any errors.
Blinking fast Connecting new client (blinking 5 s)
WiFi WiFi status
and activity
Green
Solid WiFi configured and enabled
N/A Off CATV disabled
Green Solid CATV configured and enabled, signal OK
CATV CATV status
Red Solid CATV configured and enabled, signal too low (-10.5
dBm) or unavailable
All Device
status Green Oscillating Boot/reboot in progress
All Device
status Green Pulsing Firmware upgrade in progress
Note
The LED panel functioning can be adjusted from the web interface. For instructions on how
to do this, see Managing LEDs behaviour in the Changing administrator settings section.
Connectors
The Icotera i6800 front panel includes all the local user connectors that are four RJ-45 10Base-
T/100Base-TX/1000Base-T ports, two USB ports, two POTS phone ports and one F-type CATV
RF output port. Optical fiber connectors are placed inside the device.
Power Port
The power port accepts DC 12V power source. It is important to make sure that the proper power
adapter is suitable to a particular region.
On/Off Switch
The On/Off switch enables you to switch the i6800 on or off, as well as reboot the i6800 and
restore the last saved configuration.
Reset Button
The Reset button has four modes of operation:
• when CPE is operating - pressed for less than 10 seconds: restarts CPE.
• when CPE is operating - pressed for more than 10 seconds: restores default CPE settings.
• when CPE is off - power-on with reset button pressed for less than 10 seconds: restores
default CPE settings.
• when CPE is off - power-on with reset button pressed for more than 10 seconds: boots
CPE from the second bank.
Serial Number
The serial number of the Icotera i6800 consists of 16 digits. The format of the serial number
is PPPPVVWWYYXXXXXX, where PPPP is the product ID, VV is the product variant, WW is
the production week, YY is the production year, and XXXXXX is the running serial number.
For example 6801010515123450 would be a serial number of a 01 variant of the i6801 device
(i6801-01), produced in the 5th week of 2015, with a running number of 123450.

8
Configuring and managing the i6800
This chapter provides a comprehensive overview of the Icotera i6800 configuration and
management features. It focuses on managing the device using the web interface, as this
interface is the only method of device management available to the end user.
Web interface general overview
After a successful login, the main window of the web interface is displayed. By default, it is the
System information submenu of the Status menu. The following figure presents the structure
of the web interface.
Figure 3. Icotera i6800 web interface
Top bar
Thetopbarcontains the Icotera logo, device designation, drop-down list whichenablestochoose
interface language, and the Log out button.
Menu
The menu has a form of a collapsible list of available options, which are grouped into two levels:
main and secondary. The main level provides access to general i6800 management categories,
whilethesecondarylevelpresents asubmenuof availableoptionsfor agivencategory. Bydefault
all menu options are expanded, but they can be collapsed by clicking chosen main menu entries.

Configuring and managing the i6800
9
Figure 4. Collapsing i6800 web interface menu
Management area
The management area is where all the i6800 management and status information are displayed
and modified. Depending on the selected option, it can display a set of particular configuration
options or a list of current i6800 status information.
Bottom bar
In the centre of the bottom bar, there are three buttons:
•Reset: resets all changes made in the current session.
•Save: saves all changes made in the current session.
•Apply: applies all changes saved during the current session.
The right-hand side of the bottom bar may contain an operator’s logo.

Configuring and managing the i6800
10
Logging in to the web interface
Complete the following steps to log in to the web interface:
1. Enter the address of your i6800 unit in the address bar of your web browser. The following
login prompt will be displayed.
Figure 5. Icotera i6800 login prompt
2. Enter your username and password in the respective fields.
3. Click the Log in button to log in or use the Clear button to clear both fields and type your
credentials again.
Important
The first time you log in, use the username and password provided by your network
operator. After the first login you will be able to change your credentials using the
Administration > UI login password menu.
Table des matières
Autres manuels Icotera Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur