HBK PW15PH Manuel utilisateur

PW15PH
ENGLISH DEUTSCH FRANÇAIS
Mounting Instructions
Montageanleitung
Notice de montage

Hottinger Brüel & Kjaer GmbH
Im Tiefen See 45
D-64293 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbkworld.com
Mat.: 7-0201.0015-1
DVS: A03392 03 Y00 01
06.2023
EHottinger Brüel & Kjaer GmbH
Subject to modifications.
All product descriptions are for general information
only. They are not to be understood as a guarantee of
quality or durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allge
meiner Form. Sie stellen keine Beschaffenheits- oder
Haltbarkeitsgarantie dar.
Sous réserve de modifications.
Les caractéristiques indiquées ne décrivent nos
produits que sous une forme générale. Elles
n'impliquent aucune garantie de qualité ou de
durabilité.

PW15PH
ENGLISH DEUTSCH FRANÇAIS
Mounting Instructions

PW15PH
TABLE OF CONTENTS
2
TABLE OF CONTENTS
1 Safety instructions 3................................................
2 Markings used 6....................................................
2.1 Markings used in this document 6.....................................
2.2 Symbols on the device 6.............................................
3 Application 7.......................................................
4 Mechanical installation 8............................................
4.1 Mounting instructions 8..............................................
4.2 Load application 8..................................................
5 Electrical connection 10..............................................
5.1 Connection in a six-wire configuration 10................................
5.2 Connection in a four-wire configuration 11...............................
5.3 Shortening the cable 11...............................................
5.4 Extending the cable 11................................................
5.5 Parallel connection 11................................................
5.6 EMC protection 11...................................................
6 Corrosion protection and maintenance 13...............................
7 Specifications 14....................................................
8 Dimensions 15......................................................
9 Accessories 16......................................................

3
PW15PH
SAFETY INSTRUCTIONS
1 SAFETY INSTRUCTIONS
Intended use
Load cells of the PW15PH…type series are designed for technical weighing applications
within the load limits detailed in the specifications. Any other use is not the intended use.
The load cells may only be installed by qualified personnel in compliance with the specifi
cations and with the safety requirements and regulations of these mounting instructions.
It is also essential to observe the applicable legal and safety regulations for the applica
tion concerned. The same applies to the use of accessories.
Load cells are not intended for use as safety components. Please also refer to the “Addi
tional safety precautions” section. Proper and safe operation of the load cells requires
proper transportation, correct storage, siting and mounting, and careful operation.
Load-carrying capacity limits
Comply with the data in the technical data sheets when using the load cells. The respec
tive specified maximum loads in particular must never be exceeded. Do not exceed the
values stated in the technical data sheets, for example, for
Slimit load
Slateral load limiting
Sbreaking loads
Stemperature limits
Slimits of electrical load-carrying capacity
Note that when several load cells are installed in a scale, there is not always an even load
distribution on the individual load cells.
Use as machine elements
The load cells can be used as machine elements. When used in this manner, it must be
noted that, to favor greater sensitivity, the load cell is not designed with the safety factors
usual in mechanical engineering. Please refer to the “Load-carrying capacity limits” sec
tion and the specifications.
Accident prevention
The applicable accident prevention regulations from employers’ liability insurance associ
ations must be taken into account, even though the stated load in the destructive range is
well in excess of the full scale value.

PW15PH
SAFETY INSTRUCTIONS
4
Additional safety precautions
Load cells cannot (as passive transducers) implement any (safety-relevant) cutoffs. This
requires additional components and constructive measures, for which the installer and
operator of the plant is responsible.
In cases where a breakage or malfunction of the load cells would cause injury to persons
or damage to equipment, the user must take appropriate additional safety measures that
meet at least the requirements of applicable safety and accident prevention regulations
(e.g. automatic emergency shutdown, overload protection, catch straps or chains, or
other fall protection).
The electronic processor that processes the measurement signal should be designed so
that failure of the measurement signal cannot lead to secondary failures.
General dangers of failing to follow the safety instructions
Load cells are state-of-the-art and reliable. Transducers can give rise to residual dangers
if they are mounted, installed, used and operated inappropriately or by untrained person
nel. Everyone involved with siting, starting up, operating or repairing a load cell must have
read and understood the mounting instructions and in particular the technical safety
instructions. Load cells may be damaged or destroyed by improper use or non-compli
ance with the mounting and operating manual, these safety instructions or any other
applicable safety regulations (safety and accident prevention regulations of employers’
liability insurance associations) when handling the load cells. Load cells can break, partic
ularly if overloaded. The breakage of a load cell can also cause damage to property or
injury to persons in the vicinity of the load cell.
If load cells are not used according to their designated use, or if the safety instructions or
specifications in the mounting and operating manual are ignored, it is also possible that
the load cells may fail or malfunction, with the result that persons or property may be
affected (due to the loads acting on or being monitored by the load cells).
The scope of supply and performance of the transducer covers only a small area of
weighing technology, as measurements with (resistive) strain gage sensors presuppose
the use of electronic signal conditioning. In addition, equipment planners, installers and
operators should plan, implement and respond to the safety engineering considerations
of the weighing technology in such a way as to minimize residual dangers. Pertinent
national and local regulations must be complied with.
Conversions and modifications
The design or safety engineering of the transducer must not be modified without our
express permission. Any modification shall exclude all liability on our part for any dam
age resulting therefrom.
Resale
If the load cell is resold, these mounting instructions must be included with the load cell.

5
PW15PH
SAFETY INSTRUCTIONS
Environmental protection, disposal
In accordance with national and local environmental protection, material recovery and
recycling regulations, old transducers that are no longer serviceable must be disposed of
separately from normal household waste.
If you require more information about disposal, please contact your local authorities or
the dealer from whom you purchased the product.
Qualified personnel
Qualified personnel means persons entrusted with installing, mounting, starting up and
operating the product, who possess the appropriate qualifications for their function.
This includes people who meet at least one of the three following criteria:
1. Knowledge of the safety concepts of automation technology is a requirement and as
project personnel, you must be familiar with these concepts.
2. As automation plant operating personnel, you have been instructed how to handle the
machinery. You are familiar with the operation of the equipment and technologies
described in this documentation.
3. As commissioning engineers or service engineers, you have successfully completed
the training to repair the automation systems. You are also authorized to operate,
ground and mark circuits and equipment in accordance with safety engineering stan
dards.

PW15PH
MARKINGS USED
6
2 MARKINGS USED
2.1 Markings used in this document
Important instructions for your safety are highlighted. Following these instructions is
essential in order to prevent accidents and damage to property.
Symbol Significance
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements can
lead to damage to property.
Important
This marking draws your attention to important in
formation about the product or about handling the
product.
Tip
This marking indicates application tips or other
information that is useful to you.
Information
This marking draws your attention to information
about the product or about handling the product.
Emphasis
See …
Italics are used to emphasize and highlight text and
identify references to sections, diagrams, or external
documents and files.
2.2 Symbols on the device
CE mark
With the CE mark, the manufacturer guarantees that the product
complies with the requirements of the relevant EC directives (the
Declaration of Conformity can be found on the HBM website
HBM (www.hbm.com) under HBMdoc).
Statutory waste disposal marking
In accordance with national and local environmental protection
and material recovery and recycling regulations, old devices that
can no longer be used must be disposed of separately and not
with normal household garbage.
If you need more information about disposal, please contact
your local authorities or the dealer from whom you purchased
the product.

7
PW15PH
APPLICATION
3 APPLICATION
PW15PH... single-point load cells are available in four maximum capacity ranges from 10
kg to 100 kg. They are suitable for use in the food, packaging and chemicals industries,
and also in retail and agriculture. They are ideal for use in conveyor, floor, shop and
counter scales, as well as in filling and production plants. The PW15PH... load cell is her
metically encapsulated and has the maximum IP rating IP68/IP69K. It also features an
M12 connector plug. Connection cables in various versions and lengths are available as
an option. The load cell is exceptionally rugged and delivers stable results even in
extreme ambient conditions.

PW15PH
MECHANICAL INSTALLATION
8
4 MECHANICAL INSTALLATION
4.1 Mounting instructions
When mounting the load cells, pay attention to the following:
SPlease handle load cells with care!
SLoad cells are precision sensors and so their achievable accuracy depends greatly on
their being mounted correctly!
SUse suitable hoisting gear for mounting the weighing device!
SDo not overload load cells even briefly (e.g. due to unevenly distributed support
loads)!
SWhen carrying out adjustment work that could endanger the load cells, use supports
(dummies) of equal height!
SAvoid lateral forces and torques.
SDepending on the construction, use anti-liftoff devices and limit stops if necessary!
SProtect load cells against
-one-sided heat radiation
-the influences of subsequent welding work
-strong temperature variations!
Notice
Load cells are precision measuring elements and need to be handled carefully. Dropping or
knocking the transducer may cause permanent damage. Make sure that the transducer
cannot be overloaded, including while it is being mounted.
4.2 Load application
Attach the load cells at the mounting holes and apply the load to the other end. The table
below contains the required screws and tightening torques:
Maximum capacities Thread Min. property class Tightening torque1)
10 …100kg M6 10.9 14 N⋅m
1) Recommendedvalue for the specified property class. Please note the information on screw dimensions
provided by the screw manufacturer.
Important
Load must not be applied to the side where the cable connection is located, as this would
cause a force shunt.
Table des matières
Langues :
Autres manuels HBK Équipement industriel

HBK
HBK PMX Manuel utilisateur

HBK
HBK BraggMETER SI Manuel utilisateur

HBK
HBK FIT-AED-Kit Manuel utilisateur

HBK
HBK U3 Manuel utilisateur

HBK
HBK PW27BP Manuel utilisateur

HBK
HBK RTN Manuel utilisateur

HBK
HBK PW37P Manuel utilisateur

HBK
HBK U9C Manuel utilisateur

HBK
HBK C16M Manuel utilisateur

HBK
HBK T40MS Manuel utilisateur






















