Graco 26A530 Manuel utilisateur

3A5278B
EN
Instructions
Communications Gateway
Module for XM™Sprayers
For use with XM Plural-Component Sprayers to provide enhanced fieldbus
communications abilities. For professional use only.
Not approved for use in explosive atmospheres or hazardous locations.
See page 2 for part and XM model information.
Important Safety Instructions
Read all warnings and instructions in this
manual and in the XM Plural-Component
Sprayers Operation manual. Save all
instructions.
WLD
CGM with EtherNet/IP connector shown

Related Manuals
23A5278B
Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
XM Model Options . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CGM Upgrade Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System Overview . . . . . . . . . . . . . . . . . . . . . . . . 3
CGM Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Install Upgrade Tokens . . . . . . . . . . . . . . . . . . . . 4
Install or Update Data Map . . . . . . . . . . . . . . . . . 5
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fieldbus Configuration Screens . . . . . . . . . . . . . 6
CGM I/O Data Map . . . . . . . . . . . . . . . . . . . . . . 11
Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
I/O Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 24
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 24
Related Manuals
XM Model Options
The Communications Gateway Module can be used with the following XM models. These are not for use in explosive
atmospheres or hazardous locations. See the XM Operation manual (MM 312359) for details of these models.
•XMxAxx
•XMxBxx
•XMxCxx
CGM Upgrade Kit
The following kits contain the hardware and software needed to add a Communications Gateway Module (CGM) to
an XM system.
Manual Description
312864 Communications Gateway Module,
Instructions-Parts
312359 XM Operation
3A1244 Graco Control Architecture™Module
Programming
Part Number Fieldbus
26A530 DeviceNet
26A531 EtherNet/IP
26A532 PROFIBUS
26A533 PROFINET

Overview
3A5278B 3
Overview
System Overview
The XM plural component sprayer supports a
Communications Gateway Module (CGM) that provides
a control link between the XM system and a selected
fieldbus.
CGM Overview
The Communications Gateway Module (CGM) provides
a control link between the XM system and a selected
fieldbus. This provides the means for remote monitoring
and control by external automation systems.
See CGM I/O Data Map, page 11, for a list of internal
data from the XM system that can be viewed or modified
by your fieldbus master.
NOTE: The following system network configuration files
are available at www.graco.com.
• EDS file: DeviceNet or EtherNet/IP fieldbus
networks
• GSD file: PROFIBUS fieldbus networks
• GSDML: PROFINET fieldbus networks

Installation
43A5278B
Installation
The Communications Gateway Module must be
installed in the XM system. The XM system does not
provide a mounting position for this module. It will need
a cable connection to the display module and can be
mounted either close by or at a distance of up to 50 ft
(50 m).
After installing the CGM as desired, connect the CAN
cable adapter (3) to the open connection on the display
module. Connect the CAN cable (2) to the adapter.
Connect the other end of the CAN cable to either of the
two connectors on the CGM. Alternate lengths of the
CAN cable are available and listed in Parts, page 22.
Install Upgrade Tokens
NOTE: The XM system requires updated software to
use the CGM. See Parts, page 22, for details.
To install software upgrades:
1. Use software token (4). See the Graco Control
Architecture™(GCA) Module Programming manual
for instructions.
NOTE: Upgrade all modules in the system to the
software version on the token. Different software
versions may not be compatible.
All data in the module (system settings, USB logs
maintenance counters) may be reset to factory default
settings. Download all settings and user preferences to
a USB before the upgrade, for ease of restoring them
following the upgrade.
The software version history for each system can be
viewed in the technical support section at
www.graco.com.
WARNING
ELECTRIC SHOCK HAZARD
To prevent electric shock:
• Turn off and disconnect power at XM
system main switch before installing
the Communications Gateway Module,
disconnecting any cables, or servicing
equipment.
• All electrical wiring must be done by a
qualified electrician and comply with all
local codes and regulations.

Installation
3A5278B 5
Install or Update Data Map
NOTE: The fieldbus connection is temporarily disabled
during the installation or update of a map token.
1. Ensure the system is inactive.
2. Remove access cover (A).
3. Insert and press map token (5) firmly into slot.
4. Press and hold the map upload push button (B) for
three seconds. The red LED (C) will flash twice,
pause, and repeat once after the data map is
successfully uploaded. This may take up to 10
seconds.
NOTE: The rotary switch (D) has no function for the
CGM.
5. Remove token (5). Store in a safe place.
6. Replace access cover (A).
FIG. 1: Remove Access Cover
ti12319a
A
FIG. 2: Insert Map Token
ti12320a
C
D
5B

Setup
63A5278B
Setup
Fieldbus Configuration Screens
The fieldbus screens are shown only if a CGM is
connected to your system. Find your fieldbus type in the
following table to identify parameters you can view or
edit.
1. Access the fieldbus screens from the setup mode
screens.
2. Turn setup key to enter Setup Mode.
3. Press to go to system setup screens.
4. Press multiple times as needed to go to
fieldbus screens.
NOTE: The fieldbus screen will not display if CAN
cables are not connected. Ensure that all CGM CAN
cables are connected.
PROFIBUS Fieldbus Screens
Screen 1
This screen enables you to set the hardware revision,
system serial number, device address, and installation
date.
Fieldbus Screens Page
PROFIBUS 6
PROFINET 7
DeviceNet 9
EtherNet/IP 10
FIG. 3: PROFIBUS Fieldbus Screen 1
Parameter Range
Hardware
Revision
0-9999
System Serial # 00000000-99999999
Device Address 000-126
Install Date Set as required. Use format shown in
figure above. Validate date and time
before saving.

Setup
3A5278B 7
Screen 2
Enter identification information for the CGM used in your
system.
Screen 3
This screen lists identification information for the
Datamap that has been loaded into the CGM.
PROFINET Fieldbus Screens
Screen 1
This screens enables you to set the hardware revision,
system serial number, IP address, station name, and
installation date.
FIG. 4: PROFIBUS Fieldbus Screen 2
Parameter Range
Location Tag 22 characters available
Function Tag 32 characters available
Description 54 characters available
FIG. 5: PROFIBUS Fieldbus Screen 3
FIG. 6: PROFINET Fieldbus Screen 1
Parameter Range
Hardware
Revision
System Serial #
IP Address Set as required
Install Date Set as required. Use format shown
in figure above. Validate date and
time before saving.
Station Name Required at installation. 32
characters available.

Setup
83A5278B
Screen 2
This screen enables you to change settings for DHCP,
Subnet Mask, Gateway, DNS 1, and DNS 2.
Screen 3
Enter identification information for the CGM used in your
system.
Screen 4
This screen lists identification information for the
Datamap that has been loaded into the CGM.
FIG. 7: PROFINET Fieldbus Screen 2
Parameter Range
DHCP
Yes or No
Subnet Mask Set as required
Gateway Set as required
DNS1 Set as required
DNS2 Set as required
FIG. 8: PROFINET Fieldbus Screen 3
Parameter Range
Location Tag 22 characters available
Function Tag 32 characters available
Description 54 characters available
FIG. 9: PROFINET Fieldbus Screen 4

Setup
3A5278B 9
DeviceNet Fieldbus Screens
Screen 1
This screen enables you to set the hardware revision,
system serial number, device address, and baud rate.
Screen 2
This screen lists identification information for the
Datamap that has been loaded into the CGM.
FIG. 10: DeviceNet Fieldbus Screen 1
Parameter Range
Hardware
Revision
System Serial #
Device Address 00-63
Baud Rate 125, 250, or 500
FIG. 11: DeviceNet Fieldbus Screen 2

Setup
10 3A5278B
EtherNet/IP Fieldbus Screens
Screen 1
This screen enables you to set the hardware revision,
system serial number, and the IP address.
Screen 2
This screen enables you to change settings for DHCP,
Subnet Mask, Gateway, DNS 1, and DNS 2.
Screen 3
This screen lists identification information for the
Datamap that has been loaded into the CGM.
FIG. 12: EtherNet/IP Fieldbus Screen 1
Parameter Range
Hardware
Revision
System Serial #
IP Address Required at installation
FIG. 13: EtherNet/IP Fieldbus Screen 2
Parameter Range
DHCP
Yes or No
Subnet Mask Set as desired
Gateway Set as desired
DNS 1 Set as desired
DNS 2 Set as desired
FIG. 14: EtherNet/IP Fieldbus Screen 3
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Graco Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur