1
WARNING: Do not exceed 22V input for the Link. Doing so can
cause serious damage to the Yeti and potential bodily injury. Take
note of voltages when using third party solar panels or third party
lead acid batteries with the module. Do not chain solar panels
or lead acid batteries in series (positive to negative, positive to
negative, etc.), as this can result in dangerously high voltages.
WARNING: Never connect a power source to the Yeti Link before
installing into the Yeti. Always connect the Link to the Yeti before
connecting any power source.
IMPORTANT SAFETY INSTRUCTIONS
Please save these instructions
Read all the instructions and cautions before
beginning installation.
No liability is assumed for damages resulting in the use of the
information contained herein.
CAUTION: The Goal Zero Yeti Link outputs very high amperages. Use
only with Goal Zero cables. Altered cables or connectors or 3rd Party
cables or connectors may be incompatible and may cause damage to
components, vehicle or person.
WARNING To reduce risk of fire, injury to persons or damage to
property, use only in the manner intended by Goal Zero
Do NOT disassemble or attempt to repair the module.
Do NOT allow water to enter the module, the Goal Zero Yeti Lithium, or
the Goal Zero Yeti Tank.
Ensure cable is fully inserted and tightly in place before use. Check
upon subsequent uses. For questions, contact Solutions Center at
Do NOT chain third party solar panels or lead acid batteries in series
(connecting positive to negative, positive to negative, etc.), as this
can result in dangerously high levels of voltage that can cause serious
damage to the Yeti Lithium and potential bodily injury.
Compatible with Yeti 1000, 1000X, 1400, 1500X, 3000, 3000X,
and Yeti 6000X Lithium Power Stations

2
GET TO KNOW YOUR GEAR
Data Transfer Connector
Master 8mm Input
for Yeti Link & Yeti Tank
Expansion Battery
Input Charge Indicator
Pinhole Reset
Button
Lead-Acid State of
Charge Indicator
Blue Connector
Fan Vent
Front of Link Expansion Module

3
EC8 External Battery
Connector
Fan Vent
Back of Link Expansion module
Ensure cable is fully inserted and tightly in place before use. Check
upon subsequent uses. For questions, contact Solutions Center at

4
HOW TO INSTALL
Tools you’ll need: Phillips Screwdriver
1. Turn off all the output ports and unplug the Yeti from any power
source.
2. Open the lid of the Yeti and remove the expansion module carriage
from the Yeti by removing the six screws and sliding out the
carriage.
3. Insert the included Link Lock into the opening facing the back of
the Yeti and line up the screw holes on the Link Lock with the holes
on the Yeti.
4. Take the blue connector and micro -USB cable on the Link module and
insert them into the module and micro-USB ports on the Yeti, matching
positive to positive, negative to negative, and micro to micro.

5
5. Gently set the Link into place, tucking the cables into the opening.
6. Using the provided four screws, secure the Link into place.
7. Using the 8mm port, plug the power source into the Link.
Black Cable (-)
-
Red Cable (+)
Blue Connector
Data Transfer
Connector
+
Ensure cable is fully inserted and tightly in place before use. Check
upon subsequent uses. For questions, contact Solutions Center at
WARNING: Do not exceed 22V input for the module. Doing
so can cause serious damage to the Yeti and potential bodily
injury. Take note of voltages when using third party solar panels
with the module. Do not chain solar panels in series (positive
to negative, positive to negative, etc.), as this can result in
dangerously high voltages.

6
Ensure cable is fully inserted and tightly in place before use. Check
upon subsequent uses. For questions, contact Solutions Center at
8. Proceed to plug in the EC8 cable and slide either the straight or the
90-degree EC8 cable holder over the cable and into the slots of the Link
Lock. When the power source is correctly plugged in, the Input Charge
Indicator light will turn blue. When the Tank is correctly connected to the
Link and the power source is plugged in, the Lead-Acid State of Charge
Indicator light will begin flashing green. NOTE: Upon plug-in, all LEDs will
turn on, then off before correct lights are displayed. This may take up to
30 seconds.
9. Power source will charge the Yeti first. When the Yeti is fully charged,
power will begin to store in the Tank. NOTE: Power coming in from the
8mm port will flow through the Tank first and then into the Yeti. Without
a Tank or third party battery attached, this port will not charge the Yeti
directly.
EC8 External
Battery Cable
or

7
8mm Output
Power Supply
(Included)
Yeti Link
Expansion Module
HOW IT WORKS WITH HOME ENERGY STORAGE - TANK MODE
The Goal Zero Yeti Link Expansion Module integrates with a Goal Zero
Yeti Lithium or Yeti X Portable Power Station and Goal Zero Yeti Tank
Expansion Battery to increase your energy storage capacity. The Link is
a Lithium Charge Controller that will draw up to 80A Max Current from a
Lead-Acid power source.
AC Wall
Outlet
Goal Zero
Solar Panels
(Sold Separately)
Goal Zero Yeti Tank
Expansion Battery
Goal Zero Lithium Yeti and
Goal Zero Yeti Link Expansion Module
REQUIRED (sold separately) REQUIRED (sold separately)
+

8
1. Once Link Module is installed into the Yeti you will be able to attach Goal
Zero Yeti Expansion Tanks. To do this take the male EC8 cable from the
Expansion Tank and plug it into the EC8 External Battery Connector on
the Link Module that is installed in the Yeti Power Station.
2. Then take either the included power supply or a Goal Zero Solar Panel
(sold separately) and plug the 8mm barrel connector (blue ring) into the
8mm input port on the Link Module.
Note: Do not plug a tank into itself when multiple tanks are
connected.
3. Power will flow into the battery and then into the Yeti power station.
Once the power station is full the power will then start filling up the
Tank.
NOTE
1. The 8mm port on the Link is the only way to charge both the Yeti and
Tank. Input ports on the Yeti display will only charge the Yeti, not the
Tank.
2. When Link and Tank are properly installed, power passes through the
8mm port to the Tank and then into the Yeti. Thus, without a Tank or
third party battery attached, you cannot charge the Yeti directly using
the 8mm port on the Link.
WARNING: Do not exceed 22V input for the module. Doing
so can cause serious damage to the Yeti and potential bodily
injury. Take note of voltages when using third party solar panels
with the module. Do not chain solar panels in series (positive
to negative, positive to negative, etc.), as this can result in
dangerously high voltages.
Autres manuels pour Yeti Link
3
Table des matières
Autres manuels GOAL ZERO Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur