Garland GAA10G20AC Manuel utilisateur

User Guide
GAA10G20AC
02/2023
Release Version: 4.23.1

User Guide
PacketMAX | GAA10G20AC | 4.23.1
Copyright © 2023 Garland Technology, LLC. All rights reserved.
No part of this document may be reproduced in any form or by any means without prior written permission of
Garland Technology, LLC.
The Garland Technology trademarks, service marks ("Marks") and other Garland Technology trademarks are the
property of Garland Technology, LLC. PacketMAX Series products of marks are trademarks or registered
trademarks of Garland Technology, LLC. You are not permitted to use these Marks without the prior written
consent of Garland Technology.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Garland
Technology and the customer. All or part of the products, services and features described in this document may
not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Table of Contents
1. Dashboard 5
Dashboard Panel 5
Packet Broker 6
LED Indications 6
2. System 7
System Info 8
General 8
Admin 8
Users 8
Groups 9
Authentication 9
Local Authentication Disable 10
Local Authentication Enable 10
TACACS Primary Authentication 10
TACACS Test 10
TACACS Ping Test 10
TACACS Secondary Authentication 11
TACACS Test 11
TACACS Ping Test 11
Network Settings 11
IPv4 / Disable 12
IPv4 Enable 12
IPv6 Enable 12
IPv6 Disable 13
Add SSL Certificate 13
Disable Using Uploaded SSL Certificate 13
Date & Time 14
Timezone 14
UTC 14
Manually Set Date & Time 14
NTP No Authentication (Symmetric) 14
NTP Authentication (Symmetric) 15
Syslog 15
Syslog Test 16
SNMP 16
SNMP Test 17
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
Export Configuration 17
Import Configuration 17
Software Upgrade 18
Reboot 18
3. Packet Broker 19
Tunnels 20
Encapsulate l2GRE Packets (GRE-TX Only) 20
Decapsulate l2GRE Packets (GRE-RX Only) 22
Filter Template 24
Load Balancing Group 25
Load Balancing Policy 25
Config Map 26
Ingress 27
Filters 27
Egress 28
Egress Filter 29
Config Map Save 30
Modify a Config Map 31
Delete Config Map 32
Config Map Priority 32
Method 1 33
Method 2 33
Enable/Disable Config Map 34
Disable Config Map 34
Enable Config Map 34
4. Port Info 35
Port Configuration 35
Port Description 35
Set Speed 36
Mode 36
Port Statistics 36
VLAN Tag 36
VLAN Strip 37
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
1. Dashboard
This section provides an overview of the basic dashboard architecture, default port assignments and
LED indications. The port assignments and LED indications will change on the dashboard based on
configuration changes. The dashboard provides an exact detail of the unit’s faceplate. However,
some LED indications that are displayed on the faceplate, are not displayed on the dashboard.
The dashboard provides access to the Packet Broker, Port Info and System configuration options
by selecting the desired option in the top menu bar. These options are covered in detail per their
specific sections.
Basic LED Indications
The basic LED indications are consistent regardless of configuration changes. The Ethernet and Serial
interfaces always indicate (GREEN). However, on the faceplate, the Ethernet Interface has LEDs to
indicate link and activity while there are no Serial Interface LEDs.
Dashboard Panel
LED Indications
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
PS2 Power Supply 2 LED
PS1 Power Supply 1 LED
SYS System LED
Ethernet InterfaceUpper Left LED (always illuminated)
Serial Interface Lower Left LED (always illuminated)
Packet Broker
The Packet Broker Section of the Dashboard consists of the following.
LED Indications
Port 1 L/A1 Link/Activity LED
Port 2 L/A2 Link/Activity LED
BP N/A
Port 3 Left Up Arrow Link LED
Port 4 Left Down Arrow Link LED
Port 5 Left Up Arrow Link LED
Port 6 Left Down Arrow Link LED
Port 7 Left Up Arrow Link LED
Port 8 Left Down Arrow Link LED
Port 9 Left Up Arrow Link LED
Port 10 Left Down Arrow Link LED
Port 11 Left Up Arrow Link LED
Port 12 Left Down Arrow Link LED
* The right up/down arrows for ports 3 through 12 are activity LEDs. These LEDs are N/A in the GUI.
* The L/A1 and L/A2 LEDs only indicate link in the GUI.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
2. System
The following configuration options may be displayed, modified, enabled or disabled under the System
panel.
System Info SNMP
General Export Configuration
Admin Import Configuration
Network Settings Software Upgrade
Date & Time Reboot
Syslog
1. Select System on the Dashboard Menu bar.
The System panel will be displayed. The system configuration options will be displayed
on the left side of the panel.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
System Info
The System Information panel displays the following.
Chassis Name Chassis Model Chassis Serial Number
MAC Address Software Version
1. Select System Info.
The System Information panel will be displayed.
General
The following configuration options may be displayed or modified.
Chassis Name
Key Press Timeout
1. Select General.
The General System Settings panel will be displayed.
2. Select Edit Configuration.
3. Enter the desired Chassis Name.
4. Enter the desired Key Press Timeout.
5. Select Save to save updates.
6. Select Cancel to return to the General System Settings panel.
Admin
The following configuration options may be displayed, modified, enabled or disabled.
Users
Groups
Authentication
Local
TACACS Primary
TACACS Secondary
1. Select Admin.
The Admin Settings panel will displayed.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
Users
The default user is “admin”. Changes to the default user “admin” are allowed. However, the “admin”
user may not be deleted. Users displayed on the Admin Settings panel are for local authentication
only, not used for TACACS.
1. Select Users + to create a new user.
The Create New User panel will be displayed.
2. Enter the Username.
3. Enter the Password.
4. Select the group for the user.
5. Select Save to save updates.
The new user will be displayed on the Admin Settings panel.
6. Select Cancel to return to the Admin Settings panel.
7. Edit the username, password or assigned group by selecting the pencil.
8. Delete the user by selecting the Red X.
Groups
The group defines the authorization for a user or group of users. A group may be used for local
or TACACS authorization. In Use “true” means that there is at least one local user assigned to
the group. If a group is used by TACACS, the In Use will indicate “false”. There are three default
groups, admin, OPER and NOC. All three groups may be modified, however only the OPER and
NOC groups may be deleted.
1. Select Groups + to create a new group.
The Create New Group panel will be displayed.
2. Enter the Group Name.
3. Select the desired privileges.
4. Select Save to save updates.
The new group will be displayed on the Admin Settings panel.
5. Select Cancel to return to the Admin Settings panel.
6. Modify the group privileges by selecting the pencil.
7. Deleted the group by selecting the Red X.
If a group has at least one user assigned it cannot be deleted.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

User Guide
PacketMAX | GAA10G20AC | 4.23.1
Authentication
Two authentication options are supported, local or TACACS. TACACS authentication supports two
options, primary and secondary. The TACACS primary and secondary options may be enabled or
disabled independently. Local or TACACS authentication may be enabled or disabled independently,
however, at least one option must be enabled. The TACACS primary or secondary function supports
IPv4 only, IPv6 is not supported.
1. Select Authentication Settings.
The Authentication Settings panel will be displayed. Local authentication is enabled by default.
Local Authentication Disable
1. Deselect Local Authentication.
Local authentication may only be disabled provided that TACACS authentication, primary
or secondary has previously been enabled.
2. Select Save.
Local Authentication Enable
1. Select Local Authentication.
2. Select Save.
TACACS Primary Authentication
1. Select Enable Primary.
The TACACS Primary panel will be displayed.
2. Enter the IP Address, IPv4 or IPv6.
3. Enter the Secret Word, (optional).
4. Select Save to save updates.
5. Select Cancel to return the Admin Settings panel.
TACACS Test
This option may be used to verify the authentication of a TACACS user, password and
authorization group. The TACACS Test option will be active only if TACACS authentication
has previously been enabled.
1. Select TACACS Test.
The TACACS Test panel will appear.
2. Select Primary.
3. Enter the Username.
4. Enter the Password.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
Table des matières
Autres manuels Garland Changer

Garland
Garland INT10G8SR56-SP Manuel utilisateur

Garland
Garland EdgeSafe M10GMSBPv2 Manuel utilisateur

Garland
Garland EdgeLens INT10G8SR56 Manuel utilisateur

Garland
Garland INT10G12MSFE-5 Manuel utilisateur

Garland
Garland INT10G12MSBP Manuel utilisateur

Garland
Garland P10GMSFE-5 Manuel utilisateur

Garland
Garland SFP Field TAP Series Manuel utilisateur