English
6
Defrost
The Muldeck automacally defrosts at regular me intervals, lasng a maximum of 20 minutes during which
will show. Defrost can be manually acvated by pressing and holding .
Cleaning and Maintenance
Important: Before cleaning the power supply should be turned o at the mains, please do not plug or
unplug the unit with wet hands. Only when cleaning has been completed and the unit is dry may the
Muldeck be turned back on at the mains.
Regular Maintenance:
> Air circulang in the unit should feel noceably cooler than the ambient temperature.
> As and when required, remove all product and shelving from the unit (including the base shelf – beware
of cold and or sharp components) . Clean exterior and interior surfaces with mild liquid detergent,
following the direcons on the pack at all mes. Clean surfaces with a damp cloth and clean water. Never
use wire wool or scouring pads/powders as these may cause damage.
> Clean the condenser at least once a month (it is located behind the front grille). Remove the 3 screws
at the base of the panel and drop it downwards (beware of hot and possible sharp components behind
the grille). DO NOT use a wire brush to clean the condenser only use a so brush or vacuum cleaner
to remove dirt/dust. If there are any stubborn grease deposits le on or through the condenser, call
your supplier to carry out a full service (this is normally a chargeable service). Re-t the front grille aer
cleaning.
> Failure to maintain the condenser will cause premature failure of the motor/compressor and in turn
cause premature failure of the unit. This will invalidate the warranty of the unit and its parts.
Troubleshoong
Before calling your supplier please make sure that:
> The plug is in the socket and the mains power supply is switched on i.e. are the lights and fans working?
> The fuse for the unit has not blown
> Are the lights working or able to be turned on? If not this may be due to high pressure
> The unit is posioned correctly – cold air from air condioning units & direct sunlight can aect `
performance
> The condenser is clean and not blocked
> The products are placed in the unit correctly
> The units’ air curtain is not obstructed
> Defrost is not in progress
> Check at regular intervals that the operang noise of the unit is normal and the condenser is clean
If the reason for the malfuncon cannot be idened, disconnect the electrical supply to the unit and contact
your supplier.
When requesng a service call quote the model and serial number which can be found on the silver label
located on the ceiling of the unit (starts E5…….).