Contents
CopyrightandDisclaimerNotice 2
Contents 3
1.AboutthisManual 4
1.1SafetySymbolsUsedinthisManual 4
2.force70/100/140operator 5
2.1Safetyinstructions 5
2.2Preparation 5
2.3Electricalpreparations 5
2.4Assemblingthedriveunit 6
2.5Drawings/dimensions 7
3.forceIQcontrolunit 8
3.1Installation 8
3.1.1ForceIQ230Vsinglephasepreparation 9
3.1.2ForceIQ400Vpreparation 9
3.2Technicaldata 10
3.3forceIQmenuoverview 11
3.3.1AccesstheMenu 12
3.4Programming 12
3.4.1Changingthelanguage 13
3.4.2Motorsetup 14
3.4.3Adjustingtheendposition 16
3.4.4Safetydevice 18
3.4.5Operatingmode 20
3.4.6Codeentry 20
3.4.7Specialsetup 21
3.4.8Service 24
4.Optionalplugon 26
4.1ModuleBracket 26
4.2forceLD:LoopDetector 27
4.3forceRX4:Radioreceiver 28
4.4forceTL:TrafficLights 28
4.5forcePhotocells 29
4.6forceOCE 30
4.7forcePSE 30
4.8force668LMElectroniclock 32
5.Troubleshooting 32
6.Appendix 34
6.1Additionalfunctionterminals
6.2Wiringdiagrams
6.3Declarationofincorporation

manual – forceIQ
4www.flexiforce.com
4
AboutthisManual
_____________________________________________________________
AllusersandownersoftheIndustrialdoormustread,understandandobeytheinformationand
instructionsinthismanual.Failuretodosomayresultindamageto,orfailureoftheequipment,and
possibleinjurytopersons.
ThismanualcontainsfunctionaldescriptionsandinstallationinformationforanIndustrialdoor.When
informationorinstructionsareapplicabletoallthemethodsofoperationormodels,thereareno
operatortypesormodelnumbersinthetitle.Wheninformationorinstructionsareapplicableto
specificmethodsofoperationormodels,theapplicableoperationtypeormodelnumbersappearin
thetitle.
1.1.SafetySymbolsUsedinthisManual
Thefollowingsafetysymbolsareusedinthismanual:
Indicatesageneralwarning
Indicatesanelectricalhazard
Specificusefulinformationconcerningtheinstallation.

manual – forceIQ
5www.flexiforce.com
5
2. Force70XQ/100XQ/100XC/140XQoperator
2.1. Safetyinstructions
•Followallinstructionssinceincorrectinstallationcanleadtosevereinjury.
•Checkthatthetemperaturerangemarkedontheoperatorissuitableforthelocation.
•Checkthatthedoorismovingsmoothandcorrectbeforeassemblingtheoperator.
•Checkthatthedoorisingoodmechanicalconditionandiscorrectlybalanced.
•Afterinstallation,ensurethatthemechanismisproperlyadjustedandthattheprotectionsystem
andanymanualreleasefunctioncorrectly.
•Ensurethatentrapmentbetweenthedrivenpartandthesurroundingfixedpartsduetothe
openingmovementofthedrivenpartisavoided.
•Externalpushbuttonunitsaretobelocatedwithindirectsightofthedoorbutawayfrom
movingparts.Unlessitiskeyoperated,itistobeinstalledataminimumheightof1,5mandnot
accessibletothepublic.
2.2. Preparation
Beforeyoustartmakesurethatthefollowingpreparationsaredone:
•Approval/communicationwithcustomercompleted.
•Materialsonsitearecomplete.
•Allmeasurementsarecorrect.
2.3. Electricalpreparations
Themanuallyoperateddoorneedsnoelectricalsupply.Foranelectricallyoperateddoor,thefollowing
environmentcriteriaandelectricalsuppliesarerequiredfortheoperatortofunctionproperly:
force100XQ/XC force140XQ force70XQ
Voltagesupply:+/10% 400VAC3phase50Hz,10A400VAC3phase50Hz,10A230VAC1phase50Hz,10A
Power: 0,37kW 0,55kW 0,50kW
Degreeofprotection: IP54 IP54 IP54
Weight: 13kg 13kg 11,5kg
Alloweddoorweight,max.: 400kg 650kg 350kg
Temperatureworkingrange: 15°Cto+50°C 15°Cto+50°C 10°Cto+40°C
Operatingfactor,Dutycycle: 40%S310min.Intermittent40%S310min.intermittent 25%S310min.intermittent
Dimensionsforce..XQ(hxwxd): 375x260x110mm 375x260x110mm380x110x250mm
Dimensionsforce..XC(hxwxd): 425x110x260mm

manual – forceIQ
6www.flexiforce.com
6
2.4. Assemblingthedriveunit
Thedoormustbecorrectlyinstalled,balancedandbeinclosedpositionbeforetheassemblyoftheoperator.
Fortheoperatoramountingattachmentof>500Nisrequired.
1. Attachthefirststopringtotheshaft.
2. Attachthewallbracketwith4screwsandwasherstothemotor.
3. Pushtheoperatorcompletelyagainstthestopring.
4. Mountthewallbrackettothewallwithtwosuitablescrewsandwashers.
Permountingattachment>500Nisrequired.
5. Disengagethedriveunitfromthedoorshaftbymovingthehandleclockwiseuntilitstops,
thenaimforthekeywaysatthedoorshaftandtheoperator.*Thewedgeshouldprotrudea
fewmmfromthewallbracket.
6. Attachthesecondstopring.Agapofafewmmshouldremainbetweenthestopringand
thewallbracket.
7. Tightenallscrews.
8. Routethecabledowntothecontrolunit.

manual – forceIQ
7www.flexiforce.com
7
2.5 Drawings/dimensions
_____________________________________________________________________________________
Force100XQ/140XQ
Force100XC

manual – forceIQ
8www.flexiforce.com
8
3.forceIQcontrolunit
3.1Installation
1. Attherearofthecontrolunityouhavetoassemble4enclosurebracketsbeforemountingitto
thewall.Usethefoursmall5x12screws.
2. MounttheControlunitapprox.1.7mabovethefloor(measuredfromtheuppersideofthe
box).
3. Connectthecablesfromthedoorleafandthedriveunit,accordingintheinstructionsbythe
wiringdiagram.Thecontrolunitisnowassembledandreadytobefunctionallyinstalled.See
paragraph"Programming"concerningtheprogrammingprocedure.
4. CheckthecontrolboardoftheForceIQifitispreparedfor230Vor400Voperator.Seenext
pagefortherightpreparation.
1

manual – forceIQ
9www.flexiforce.com
9
3.1.1ForceIQ230Vsinglephasepreparation
ConnectasbelowwhenyouusetheForceIQwitha230Vsinglephasemotor.
MakesureFuseF4is100mAmediumandthatKL131andKL132areconnectedtogether.
____________________________________________________________________________________________________
3.1.2ForceIQ400Vpreparation
ConnectasbelowwhenyouusetheForceIQwitha400Vmotor.
MakesureFuseF4is80mAslowandthatKL132andKL133areconnectedtogether.
230V
Medium
Slow

manual – forceIQ
10www.flexiforce.com
10
3.2Technicaldata
Dimensions(approx.): 345x215x135mm
MainsupplyvoltageL1,L2,L3,N,PE:forceIQ400V,50HZ/forceIQ230230V,50Hz.
Fuseprotection 10AKcharacteristic
Voltage 24VDC,max.320mA
Accessinput 24VDC,Allinputsmustbeabsolutelypotentialfreeconnected.
Minimumdurationofinputsignalcontrolcommand>100ms.
Safetycircuit/Emergencystop Connectallinputsabsolutelypotentialfree;atinterruptionin
thesecuritycircuit,itisnotlongerpossibleofelectrical
operationofthemotor,eveninholdtorunmode.
Inputsafetyrail Forelectricalsafetystripswith8.2kΩ,loadresistorandfor
dynamicopticalsystems.
Relayoutput Ifusedaspowerswitchingcontacts,itcannotservemoresmall
electriccurrents.
Temperaturerange: 15°C+50°C
Protection IP54(inhousing)
Weight Ca.2.2kg
Ce manuel convient aux modèles suivants
8
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur