FS Series 3 PV Module User Guide—North America | Page 6 of 13
PD-5-200-03 NA | REV 2.1 | 02771_UG_NA_24OCT12
Modulesshouldnotbeinstalledinawaythatrestrictsaircirculaontothebacksideofthemodule.Modulesgenerateheat
andrequireadequateairowforcooling.
Installaonlocaonsandmodulesupportstructuresshouldbeselectedtoensuremodulesandconnectors(openormated)
areneversubmersedinstandingwater.FirstSolarmodulesaretestedandceredforapplicaonsinvolvingpressuresfrom
snow/ice/windupto2400Pa(50.13lb/2)whenmountedproperly.Snowdriscouldresultinanonuniformloadingofthe
moduleswhichexceedsthetestedpressure.Ifitisexpectedthatloadswillexceed2400Pa(50.13lb/2),itisrecommended
toclearsnowfrommodules,andensurethatice/thaw/freezecyclesundersnowdrisdonotresultinexcessivestresseson
the module.
Heavyconstruconandtrenchingshouldbecompletedpriortomoduleinstallaontominimizedebrisanddust.
Ensureanysoilbindingagentsorsaltsusedforon-sitedustcontroldonotspray,splash,ordriontothesurfaceofthe
modules.
TheULapproveddesignloadofFSSeries3PVModulesis30lb/2(1436Pa).
Maximumallowablepressureonmodulesmaynotexceed2400Pa(50.13lb/2)withoutaddionalmodulesupportthat
mustbetestedandapprovedbyFirstSolar.
Forrooopmounng,modulesmustbemountedoverareresistantroofcoveringratedfortheapplicaon.The
recommendedminimumstandoheightis3.25in(82.55mm).ModulesusedinULListedrooopapplicaonsmustbe
installedwithapprovedmounngsystemsasspeciedinFirstSolarApplicaonNotePD-5-320NA.Ifalternatemounng
meansareemployed,thismayaecttheLisngreclassrangs.Thererangofthismoduleisvalidonlywhenmounted
inthemannerspeciedinthemechanicalmounnginstrucons.
4.2 Locaon,AngleandTilt
Tomaximizeperformance,modulesshouldbelocatedinanareathatreceivesdirectsunlightfrommid-morningto
midaernoon(typically9:00a.m.to3:00p.m.).Installaonmustavoidlocangthemoduleswhereshadowsmaybecaused
bybuildings,trees,etc.
PVperformancemodelingsowareshouldbeusedtodeterminetheopmumorientaonandltangleforeachlocaon.
Forltedfree-eldapplicaonswherethereisrowtorowshading,itisrequiredtoinstallthemodulesinlandscape
orientaon.PleaserefertoFirstSolarApplicaonNotePD-5-425-03foraddionalinformaon.
4.3 ElectricalInterconnecon
FirstSolarFSSeries3PVModulesarepre-conguredwithindustrystandardconnectorsthatare“touchproof”withall
livepartsprotectedagainstaccidentalcontactandprotectedagainstpolarityreversal.TheconnectorsareUVandweather
resistantfrom–40°Cto+90°C,andratedfor1000VDCand30A(beforederangforambienttemperature).
Damaged wires, connectors, or juncon boxes may cause ground faults, and associated electrical hazards,
including electrical shock. To avoid these condions:
• Protect unmated connectors from dust and moisture by using sealing caps (not provided, available from connector
manufacturer).
!