FineTek SIS Manuel technique

I
SIS Programmer Box
Operation Instruction
FineTek Co., Ltd.
No.16, Tzuchiang St., Tucheng Industrial Park, New Taipei City 23678
Tel: 886-2-22696789 Fax: 886-2-22686682
Website: http://www.fine-tek.com E-mail:[email protected]
08-SISPAXX-B1-EK,07/25/2019

II
Contents
1. Reading Labels........................................................................................................3
1.1 Service Network........................................................................................4
2. Product Features.....................................................................................................5
3. Scope of Application...............................................................................................5
4. Ambient Conditions ................................................................................................5
5. Installation................................................................................................................6
5.1 System Requirements...............................................................................6
5.2 Program Installation..................................................................................6
5.3 Uninstall process.......................................................................................8
5.4 Electrical Connection................................................................................9
6. Operation................................................................................................................10
6.1 Buttons....................................................................................................10
6.2 Function Settings....................................................................................13
6.2.1Parameter Modification.........................................................................14
6.2.2Saving and Loading..............................................................................14
6.2.3Output Function Selection.....................................................................14
6.2.4Output Delay Time Setting....................................................................14
6.2.5Fault Alarm Output Setting....................................................................14
6.2.6Sensitivity Setting..................................................................................15
6.2.7Common Material Selection..................................................................15
6.3 Advanced Settings..................................................................................15
6.3.1Advanced Setting Buttons.....................................................................15
6.3.2Operating steps for advanced settings..................................................17
7. Simple Troubleshooting........................................................................................18

3
1. Reading Labels
Thanks for purchasing FineTek’s Product. This operation manual describes the product
features, working principles, operation and maintenance methods. It makes the user fully
understand how to use the product correctly, so as to prevent dangerous situations such as
device damage or operator injury.
Please read this operation manual completely and carefully before using the product.
Please contact the company if this operation manual can’t satisfy your demands.
The content of the operation manual is updated based on the version upgrade, which
will be uploaded to the website for the user to access.
Please don’t disassemble or repair the product on your own, as this will make you
disqualified from availing of the warranty service. Please send the product back to the
company for repair and calibration, or just contact the company.
Explanation of warning signs:
Danger→ It indicates that wrong operation will cause death or major disasters.
Note→ It indicates that wrong operation will cause injury and device damage to
some extent.
Electric shock→ It warns of possible electric shock.
Fire→ It warns of possible fire.
Prohibited→ It indicates the prohibited wrong behavior.

4
1.1 Service Network
Company
Address
Telephon
Fax
Taipei
Headquarters
(Taiwan)
No.16, Tzuchiang St., Tucheng
Industrial Park, New Taipei City
23678
+886 2 2269 6789
+886 2 2268 6682
Taichung
Sales office
(Taiwan)
+886 4 2465 2820
+886 4 2463 9926
Kaohsiung
Sales office
(Taiwan)
+886 7 333 6968
+886 7 536 8758
Fine automation
Co., Ltd.
(China)
No. 451, Duhui Road,
Zhuanqiao Township, Minhang
District, Shanghai City 201109
+86 021 64907260
+86 021 6490 7276
FineTek Pte Ltd.
(Singapore Branch)
37 Kaki Bukit Place, Level 4
Singapore 416215
+65 6452 6340
+65 6734 1878
FineTek GmbH
(Germany Branch)
Bei den Kämpen 26
21220 Seevetal-Ramelsloh,
Germany
+49 (0) 4185 8083 12
+49 (0) 4185 8083 80
FineTek Co., Ltd.
(Indonesia Branch)
Ruko Golden 8 Blok H No.38
Gading Serpong, Tangerang
Indonesia 15810
+62 (21) 2923 1688
+62 (21) 2923 1988
FineTek Co., Ltd.
(Malaysia Branch)
8-05, Plaza Azalea, Persiaran
Bandaraya,
Seksyen 14, 40000 Shah Alam,
Selangor, Malaysia
+603 5524 7168
+603 5524 7698

5
2. Product Features
The SIS Programmer Box is used to transfer sensor data to a PC for reading and
editing.Supporting our SIS Impedance Spectroscopy Level Sensor series for debugging
purposes, it includes the following functions:
Reading the current parameter settings of the sensor.
Changing the parameters of the sensor.
The current values of the sensor and further verification.
Attention! The hub is not suitable to be permanently connected as an monitoring device.
3. Scope of Application
SIS Sanitary Intelligent Level Switch parameter setting.
A multi-purpose, essential modulation kit for industrial level switches.
Sensor sensitivity adjustment for material replacement.
Sensor verification for equipment maintenance.
4. Ambient Conditions
Storage temperature: -40°C ~ 85°C (-40°F ~ 185°F).
Ambient temperature: -40°C ~ 85°C (-40°F ~ 185°F).
This product is not waterproof. Moisture intrusion must be prevented when it is being
operated.
Basic configuration: Programmer Box, PC, SIS Sanitary Intelligent Level Switch, cable.

6
5. Installation
5.1 System Requirements
Microsoft Windows XP/SP3 or newer is required.
At least one available USB 2.0 port.
The Programmer Box software.
5.2 Program Installation
You must have administrator privileges.
1. Insert the CD-ROM or USB into the drive or port to start the installation or download
from the website.
2. Click the file "SIS_****_**_**_**.exe" to start the installation as shown below.
3. Select your language from the drop-down menu and click "OK".

7
4. When the setup wizard pops up, click "Next".
5. Select the Destination Folder (C:\Program Files\SIS by default) and click "Install".

8
6. When the installation is complete, click "Finish" to start the program.
7. Install the driver by inserting the CD-ROM or USB or downloading from the website.
You can also use the Windows built-in wizard to find a on-line available driver to
complete the installation.
5.3 Uninstall process
To uninstall the program, process as follows:
1. Open the program folder (C:\Program Files\SIS by default), click "uninst.exe" to start
the uninstallation (shown as below).

9
2. Click "Yes (Y)" to uninstall (as shown below).
3. Click "OK" to complete the uninstallation (as shown below).
5.4 Electrical Connection
Connect the sensor and the SIS Programmer Box to the PC as shown below.
Connect the sensor to the SIS Programmer Box using the M12 connector (please use
the standard connector to ensure stable connection).
Connect the SIS Programmer Box to the computer using USB connector.

10
6. Operation
6.1 Buttons
a. Click the Production button to open the settings page (as shown below). The setting
functions are listed below.
b.
1
7
2
4
6
5
3
8
9
22
21
20
19
18
12
13
14
15
16
17
11
10
23
24
25
Autres manuels pour SIS
1
Table des matières
Manuels Carte mère populaires d'autres marques

Telit Wireless Solutions
Telit Wireless Solutions SL869-3DR Manuel utilisateur

Gigabyte
Gigabyte GA-9IVDT Manuel utilisateur

Texas Instruments
Texas Instruments ADS8372EVM Manuel utilisateur

Commell
Commell MS-C73 Manuel utilisateur

IBT Technologies
IBT Technologies MB860 Manuel utilisateur

Nvidia
Nvidia TEGRA DG-04927-001_V01 Manuel utilisateur