Eyevision EV-H298 Manuel utilisateur

V2.1
21/08/19
Eyevisi n
Eyevisi n
Eyevisi n
Hybrid 4 Wire Video Intercom System
with Net-link
EV-H7
EV-H298KP EV-H298FKP EV-H304KP EV-H304-4B
EV-H304FKP EV-H304F-4B
EV-H298
Eyevisi n
Net Link
Eyevisi n
Eyevisi nEyevisi n
Eyevisi nEyevisi n
Eyevisi nEyevisi n Eyevisi nEyevisi n
Eyevisi nEyevisi n

Table of Contents
Page 1
Installation Hints
Precautions
Page 2
Indoor Monitor and Netlink Overview
Jumper settings for Indoor Monitor and Netlink
Page 3
Outdoor station Installation Height
Power adapter and Power supply limitations
Page 4
EV-H298 (non keypad) outdoor station installation and wiring
Page 5
EV-H298KP outdoor station installation and wiring
Page 6
EV-H304 outdoor station installation and wiring
Page 7
EV-H304-4B Apartment outdoor station installation and wiring
Page 8
Apartment System Wiring Diagram
Page 9
Home System Wiring
One indoor to one outdoor unit (with/without netlink)
One indoor to two outdoor units with netlink
Two indoor to one unit with netlink
Page 10
Home System Wiring cont.
Two indoor to two outdoor units with netlink
Four indoor to two outdoor units without netlink
Page 11
Home System Wiring cont.
Four indoor to two outdoor units with netlink
Page 12
Operating the indoor monitor
Page 13
H298KP and H304KP Keypad Programming including unlock time setting
Page 14
H298 Unlock time setting
Setting the indoor monitor to Home/Apartment mode
Page 15
Controlcam2 Installation
Overview of Controlcam 2
Page 16
Preliminary setup of Netlink using an Android Device
Page 17
Preliminary setup of Netlink using an iOS device
Page 18
Changing the device and unlock password for controlcam 2
Setting the unlock time for controlcam 2
One key unlock via APP
Page 19
Adding a device already on the WiFi network to additional phones/tablets
Adding a device connected by ethernet cable
Troubleshooting

Due to our constant developments, your purchased model functions may vary slightly to the instruction manual provided.
We always endeavor to try to update our manuals regularly in accordance with the level of new development.
Connect this unit ONLY to other compatible units, Do not connect it to any other type of alarm or auxiliary device.
Connecting anything else to this unit may damage it or prevent it from operating correctly.
Do not place the power cords from the AC/DC adapters, camera or monitor where they can be pinched or cut.
Keep cords away from children’s, pets and routine household traffic.
Do not place heavy objects on power cords or cover cords with rugs or carpet.
When the system is not in use, please unplug the AC/DC adapters from the wall outlet.
Slots or openings in the back of the monitor are provided for ventilation and to ensure reliable operation of the video monitor or equipment and to protect it from overheating.
These openings must not be blocked or covered.
The monitor should never be placed near a heater and should not be placed in a built in installation such as a bookcase unless proper ventilation is provided.
All parts of the system should be protected from shocks and vibrations.
For cleaning the Lens & Screen please do the cleaning with a soft cotton cloth, do not use organic or chemical impregnate cloths. If necessary please use a damp soft cloth to clean
dust.
Image distortion may occur if the video door phone is mounted too close to magnetic field e. g. Microwaves, TV, computer etc.
Please keep the video door monitor away from wet areas, high temperature, dust, caustic and oxidation gas in order to avoid any unpredictable damage.
Every installation may vary slightly according to the user’s requirements. The recommended height for installing the monitor and the door station should be decided by the end user
based on their requirements.
The monitor’s height should be chosen according to the users height. A good rule to follow is that the center of the monitor screen should be around nose height.
The door station camera lens should also be around nose height.
1- Carefully choose and decide on a location to install the monitor, and then make a hole in the wall so the cable can come through the hole.
2- Fix the monitor’s bracket on the wall with screws please see mounting and installation.
3- Carefully choose and decide on a location to install the outdoor door station and then make a hole in the wall according to the door station’s instructions.
4- Lay the cable for connecting the monitor to the door station then feed the cable through.
5- Connect one end of the 4-core cable to the monitors; be sure to connect the correct colours. If you are not sure then purchase the ready made shielded cables with pre terminated
end plugs and simply plug in.
6- Plug in the power cable to the back of the monitor and into the back of the door station.
7- Slip the monitor onto the installed wall bracket.
8- Connect the other end of the cable to the door station and be sure to connect the correct colours the correct terminals or purchase the ready made cable.
9- Fix the door station on the wall.
10- Plug in the power supplies into a power point.
11- Allow 30 seconds for the power to settle.
12- Now the video intercom system can be used.
13- Please see operating instructions.
Precautions
Installation Hints
Page 1

CN 2 (2nd Outdoor station)
CN 1 (1st Outdoor station)
V(+12V)
GND (Negative)
J1 Jumper
J2 Jumper
EV-H7 Indoor Monitor
Front View Rear View
Page 2
Wiring and Distances for Intercom line
Net Link and WIFI Operational Distance
Yellow (Video)
Red (B+)
Black (GND) Black (GND) is also connected with the shield at each end of the system
Blue (Audio)
The operational distance of the Net Link WIFI system greatly depends on the router in use, walls in between the two systems and other factors such as
electrical interference. This can be judged quite easily by using your mobile phones WIFI indicator and ensuring you have STRONG signal Strength. The
average distance is around 20m+ but this will vary between installations and sites.
12V DC
RJ 45/CAT5/CAT6 Ethernet Cable
Door Station 1
Door Station 2
- Maximum of FOUR indoor monitors
- Maximum of TWO outdoor units
Recommended Cable Type:
4 Core Shielded .030mm up to 100m distance.
RG 59 Coaxial Cable with 1.5mm Pair up to 200m
Eyevisi n
System jumper settings
Remove the RING jumper (J1) from the NETLINK only to eliminate a dual ringing tone on the outdoor unit. There is no need to remove the ring jumper off any
of the indoor monitors.
If the video displayed on the phone/tablet is dark also remove the COAX jumper (J2) from the netlink.
If the video displayed on the indoor monitor is dark also remove the COAX jumper (J2) from the specific indoor monitor that the problem is occurring on.
If the video displayed on the indoor monitor is dark remove the COAX jumper (J2) from the specific indoor monitor that the problem is occurring on.
Systems with a NETLINK
Systems without a NETLINK
J1 Jumper
J2 Jumper
Rear Of Indoor Monitor Rear Of Netlink
Jumpers
Jumpers
Led Indicators:
Red LED: Power ON
Green LED Flashing: Outgoing Call
Green LED ON: Connected to Network
Green LED OFF: Not connected to the network
Important !
Note that the door station that is connected to INPUT 1 is the only
door station the can be manually monitored via the APP however
both door stations can be viewed with full communications when the
doorbell is pressed.

Outdoor Station installation height
Power Supply Limitations
Please install the door station at a height no less than 145cm to the center of the door stations
camera. Recommended height is between 145cm-160cm.
If the door station is mounted to low the camera may fail in seeing the guests face and will also
present issues for communication.
Page 3
DC
AC
+
-
OUT
OUT
Standard 12V Power Adapter
* Max distance is 3m
* Recommended cable to extend length is 14/020
pair
* Only one unit per power supply
12V DC 1.5A Power Supply
* Max distance is 10m
* Recommended cable to is 14/020 pair or greater
* Max two units per power supply

1
2
3
4
5
6
1
2
3
4
5
6
To Automatic Gate
Open/Close input
Electric Striker 12V 250mA Maximum
- Fail Secure Type/Power ON to unlock
Green
Green
Red
White
White (+12V)
(Black)
Negative
Automatic Gate System Connection
Electric Striker Connection (Fail Secure) Power on to unlock
Intercom Line 1. Blue (Audio)
Intercom Line 2. Black (GND)
Intercom Line 3. Red (B+)
Intercom Line 4. Yellow (Video)
Unlock Line 5. Green (Relay N/O)
Unlock Line 6. White (Relay COM)
Intercom Line 1. Blue (Audio)
Intercom Line 2. Black (GND)
Intercom Line 3. Red (B+)
Intercom Line 4. Yellow (Video)
Unlock Line 5. Green (Relay N/O)
Unlock Line 6. White (Relay COM)
H298 Front & Rear View
LED Light
Camera
Name Plate
Speaker
Call Button
Microphone
Screws
System
Wiring
Rain Cover
Screws Plastic wall plug
Rain Cover
H298 Installation into the rain cover
Intercom Connection
Unlock
connection
H298 Standard Outdoor Station
Page 4

CN 3
CN 3
CN 3
CN 2
CN 2
CN 2
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
1
2
3
4
1
2
3
4
CN 3
1. Exit Button (First Wire- N/O)
2. Exit Button (Second Wire-
COM)
3. Relay N/O
4. Relay Common
5. Relay N/C
CN 3
1. Exit Button (First Wire- N/O)
2. Exit Button (Second Wire-
COM)
3. Relay N/O
4. Relay Common
5. Relay N/C
CN 3
1. Exit Button (First Wire- N/O)
2. Exit Button (Second Wire-
COM)
3. Relay N/O
4. Relay Common
5. Relay N/C
+
-
+
-
+
-
To Automatic Gate
Open/Close input
Electric Striker 12V 250mA Maximum
- Fail Secure Type/Power ON to unlock
Electric Striker 12V 250mA Maximum
- Fail Safe Type/Power OFF to unlock
Green
Green
Blue
Blue
Blue (+12V)
Brown (+12V)
Negative
Negative
Automatic Gate Connection
Electric Striker Connection (Fail Secure) Power on to unlock
Electric Striker Connection (Fail Safe) Power off to unlock
Page 5
H298KP Front & Rear View
H298FKP Front & Rear View
LED Light
LED Light
Camera
Camera
Name Plate
Name Plate
Keypad
Keypad
Speaker
Speaker
Call Button
Call Button
Microphone
Microphone
Screws
System
Wiring
Rain Cover
Screws Plastic wall plug
Rain Cover
H298KP Installation into the rain cover
Screws
Screws
System
Wiring
Recess Box Plastic wall plug
H298FKP Installation into the rain cover
Eyevisi nEyevisi n
Intercom
Intercom
Exit Button
Exit Button
Power Supply
Power Supply
Connection
Connection
Connection
Connection
Unlock
Unlock
connection
connection
H298 Keypad Outdoor Station
Black/White
(+12V)
Black/White
(+12V)
Black/White
(+12V)
Black
(GND / -)
Black
(GND / -)
Black
(GND / -)
Standard
Power
Adapter
Standard
Power
Adapter
Standard
Power
Adapter

H304KP Front & Rear View
H304FKP Front & Rear View
LED Light
LED Light
Camera
Camera
Keypad
Keypad
Speaker
Speaker
Call Button
Call Button
Microphone
Microphone
Screw
System
Wiring
Rain Cover
Screws Plastic wall plug
Rain Cover
H304KP Installation into the rain cover
Screws
Screws
System
Wiring
Recess Box Plastic wall plug
H304FKP Installation into the rain cover
Intercom
Intercom
Power Supply
Power Supply
Connection
Connection
Connection
Connection
Unlock
Unlock
connection
connection
Eyevisi nEyevisi n
Eyevisi nEyevisi n
Eyevisi nEyevisi n
Eyevisi nEyevisi n
H304 Keypad Outdoor Station
Black/White
(+12V)
Black/White
(+12V)
Black/White
(+12V)
Black
(GND / -)
Black
(GND / -)
Black
(GND / -)
Standard
Power
Adapter
Standard
Power
Adapter
Standard
Power
Adapter
1
2
3
1
2
3
1
2
3
1
2
3
4
1
2
3
4
1
2
3
4
CN 3
1. +12V
2. Negative/GND
CN 2
1. NO Exit Button
2. Button Common
CN 4
3. Relay N/C
4. Relay Common
5. Relay N/O
CN 3
1. Exit Button (First Wire- N/O)
2. Exit Button (Second Wire-
COM)
3. Relay N/O
4. Relay Common
5. Relay N/C
CN 3
1. Exit Button (First Wire- N/O)
2. Exit Button (Second Wire-
COM)
3. Relay N/O
4. Relay Common
5. Relay N/C
+
-
+
-
+
-
To Automatic Gate
Open/Close input
Electric Striker 12V 250mA Maximum
- Fail Secure Type/Power ON to unlock
Electric Striker 12V 250mA Maximum
- Fail Safe Type/Power OFF to unlock
COM
COM
(COM)
NO
(NO)
NC
+12V
+12V
Negative
Negative
Automatic Gate Connection
Electric Striker Connection (Fail Secure) Power on to unlock
Electric Striker Connection (Fail Safe) Power off to unlock
Page 6
B
T
N
B
T
N
B
T
N

To Automatic Gate
Open/Close input
Electric Striker
Electric Striker
Automatic Gate System Connection
Electric Striker Connection (Fail Secure) Power on to unlock
Electric Striker Connection (Fail Safe) Power off to unlock
Intercom Monitor Lines (CN 1 to CN 4)
Yellow (Video)
Red (B+)
Black (GND)
Blue (Audio)
CN6
Blue (NC)
Black (Com)
Red (NO)
Intercom Monitor Lines (CN 1 to CN 4)
Yellow (Video)
Red (B+)
Black (GND)
Blue (Audio)
CN6
Blue (NC)
Black (Com)
Red (NO)
Intercom Monitor Lines (CN 1 to CN 4)
Yellow (Video)
Red (B+)
Black (GND)
Blue (Audio)
CN6
Blue (NC)
Black (Com)
Red (NO)
H304-4B Front & Rear View
H304F-4B Front & Rear View
LED Light
LED Light
Camera
Camera
Speaker
Speaker
Call Buttons
Call Buttons
Microphone
Microphone
Screw
System
Wiring
Rain Cover
Screws Plastic wall plug
Rain Cover
H304-4B Installation into the rain cover
Screws
Screws
System
Wiring
Recess Box Plastic wall plug
H304F-4B Installation into the rain cover
Intercom
Intercom
Exit Button
Exit Button
Power Supply
Power Supply
Connection
Connection
Connection
Connection
Unlock
Unlock
connection
connection
Eyevisi nEyevisi n
Eyevisi nEyevisi n
Eyevisi nEyevisi n
Eyevisi nEyevisi n
H304-4B Apartment Outdoor Station
Standard
Power
Adapter
Standard
Power
Adapter
Standard
Power
Adapter
Black
(-)
Black
(-)
Black
(-)
Black/White
(+)
Black/White
(+)
Black/White
(+)
+
+
-
-
Page 7

12V
Adapter
12V
Adapter
12V
Adapter
12V
Adapter
12V
Adapter
12V
Adapter
2C
2C
2C
2C 2C
2C
CN 1
CN 1
CN 1
CN 1
CN 1
Input
on
each monitor
CN 2
Input
on
each monitor
CN 1
CN 1
12V
Adapter
2C
Netlink
CN 1
CN 3 CN 2
12V
Adapter
12V
Adapter
12V
Adapter
Door Striker
or Auto Gate
Door Striker
or Auto Gate
Door Striker
or Auto Gate
2C
2C 2C
2C
2C
2C
Apartment 1
12V
Adapter
2C
Apartment 1
Apartment 2
12V
Adapter
2C
Apartment 2
Apartment 3
12V
Adapter
2C
Apartment 3
Apartment 4
12V
Adapter 2C
Apartment 4
Additional monitor
Apartment 4
for apartment 2
Additional monitor
Apartment 4
System Expansion
System Expansion
Netlink Expansion
Each apartment that has its own internet
connection can have its own netlink
installed so that they can receive calls on
iOS and Android devices. The 4 wire
connection is performed directly off that
apartments intercom line in parallel with
the indoor monitor.
Note: Only apartments requiring this
feature require a netlink.
Monitor Expansion
Each apartment requiring additional
monitor(s) has the ability to do so with an
expandability of up to FOUR monitors per
apartment . The 4 wire connection is
performed directly off that apartments
intercom line in parallel with the first indoor
monitor.
12V
Adapter
2C
Netlink
CN 1
CN 3 CN 2
Netlink Expansion
Each apartment that has its own internet
connection can have its own netlink installed so
that they can receive calls on iOS and Android
devices. The 4 wire connection is performed
directly off that apartments intercom line in
parallel with the indoor monitor.
Note: Only apartments requiring this feature
require a netlink.
Monitor Expansion
Each apartment requiring additional monitor(s)
has the ability to do so with an expandability of
up to FOUR monitors per apartment . The 4 wire
connection is performed directly off that
apartments intercom line in parallel with the first
indoor monitor.
Wiring Layout One Outdoor Station
Wiring Layout Two Outdoor Station
Apartment System Wiring
for apartment 4
Page 8
Ce manuel convient aux modèles suivants
7
Table des matières
Autres manuels Eyevision Système d'interphone

Eyevision
Eyevision WF-D02S Manuel utilisateur

Eyevision
Eyevision Intelli Series Manuel utilisateur

Eyevision
Eyevision EV-TRUWL7-KP22 Manuel utilisateur

Eyevision
Eyevision EV-D298F Series Manuel utilisateur

Eyevision
Eyevision EV-DMR18S Manuel utilisateur

Eyevision
Eyevision EV-IP-KP22 Manuel utilisateur

Eyevision
Eyevision EV-V4L Manuel utilisateur

Eyevision
Eyevision EV-D301 Manuel utilisateur