Emergency Lighng Control Device
Installaon / Operaon Manual
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precauons should always
following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
This product can be used with LED Drivers, Fluorescent Ballasts, Incandescent,
/Quartz
and general use loads
Servicing shall be performed by qualified service personnel
Ensure all wiring complies with applicable standards such as NFPA, NEC, and
This product is not intended for use in wet locaons –
seal appropriately
when
Do not mount near gas or electric heaters
Do not use this equipment for other than intended use
cause an unsafe condion
WARNING
ONLY QUALIFIED
SAVE THESE INSTRUCTIONS
UL-924 Listed for Emergency Lighng
Factory Calibrated Zero-Cross switching
compared to convenonal relays
Industries lowest standby power consumpon
120 - 277 VAC Universal Input
NEMA 410 Tested
IEC 61000-4-5 Surge Tested
Aracve standard faceplate - single or
Breakaway tabs for mulple mounng
reduces relay arcing and inrush current up to 5X
is less than 0.25W @120V
mul-gang box
configuraons
be followed including the
Tungsten
local codes
using outdoors
The use of accessory equipment not recommended by the manufacturer may
TURN POWER OFF BEFORE INSTALLATION,
ELECTRICIANS SHOULD INSTALL
ELCD / ELCD-D / ELCD-F / ELCD-FD
Electrical Specications:
Inputs:
EMERGENCY, UTILITY and SWITCHED 120-277VAC, 47-63 Hz
0-10V controls (ELCD-D/FD model) 0-10V DC, 200mA maximum
Fire Alarm 12-24V AC/DC
Max Load Requirements:
LED, Ballast, Tungsten, Incandescent: 20A @ 120/277V
Standby Power Consumption: 0.25W@120V, 0.60W@277V
Dielectric Strength: 1550 VAC between ALL Inputs
Mechanical Specications:
Size: 1.73"W x 1.28"D x 2.72"H Warranty:
Weight: 4.5 oz. 5 Year full replacement
Color: RAL9003 White
Indicators: LED's - EMERGENCY (Green), UTILITY (Green), ALARM (Red) Conformance:
User Controls: Test Button UL-924, NEMA 410, IEC 6100-4-5,
Mounting: Standard electrical box or xture mount NEC, OSHA, NFPA
Breakaway tabs for mounting congurations
Environment: 0-50 deg. C
Connections: Flying Leads – Pre-Tinned
12AWG for EMERGENCY INPUT (Blue) and LOAD (Yellow)
18AWG for UTILITY (Black), SWITCHED (Red),
UTILITY NEUTRAL (White), EMERGENCY NEUTRAL (Gray)
20AWG Teon for Fire Alarm (Red), 0-10V Dimming (Violet)
Programming Mode – Changing the Time Delay function
The ELCD has 5 pre-programmed time intervals which allows the user to extend the relay’s “on time” when returning from an Emergency condition.
The factory default time interval is set to 2 seconds and can be eld modied to either No Delay, 1, 5, or 15 Minutes.
To change the time interval, press and hold the TEST button for at least 15 seconds to enter the programming mode. Once the programming mode is
entered, the ALARM LED will illuminate solid red until the TEST button is released. Once the TEST button is released, a blinking pattern between the
EMERGENCY LED and the ALARM LED will start. Blinking will alternate between the ALARM and EMERGENCY LED’s followed by a pause and then
repeated continuously. The quantity of blinks on the green EMERGENCY LED indicates which time interval is currently selected. To advance the time
interval to a different pre-programmed setting, simply press the TEST button again. The Programming mode is a continuous loop so that if the button
is pressed too many times, it will go back to the starting location. Once the desired time interval has been selected, press and hold the TEST button
for at least 5 seconds until the ALARM LED is OFF to exit the programming mode.
Programming Mode Sequence 1) One Blink = No Delay
Programming Mode Sequence 2) Two Blinks = 2 Second Time Interval (Default)
Programming Mode Sequence 3) Three Blinks = 1 Minute Time Interval
Programming Mode Sequence 4) Four Blinks = 5 Minute Time Interval
Programming Mode Sequence 5) Five Blinks = 15 Minute Time Interval
Press TEST Button
momentarily to advance
to new sequence
QUICK GUIDE - PROGRAMMING PROCEDURE (for details – see PROGRAMMING MODE description)
Step 1 – Enter the Programming mode
Step 2 – Momentarily press the TEST button to advance to the desired Time Interval
Step 3 – Exit the Programming mode
Press and Hold
(15+ Seconds) TEST
ALARM
LED ReleaseTEST Button
After ALARM LED is ON
***NOTE***
Count the blinks on the Green
EMERGENCY LED
after the Red Alarm
EMERGENCY
LED
3 Blinks = 1 Min.
2 Blink = 2 Sec.
4 Blinks = 5 Min.
5 Blink = 15 Min.
Press and Hold
TEST
TEST Release TEST Button
After ALARM LED is OFF
User Programmable Time Delay up to 15 min.
1 Blink = No Delay.
120 - 277V 20A 47-63hz
SPEC GRADE FOLLOW INSTRUCTIONS
TEST
EMERGENCY
LIGHTING CIRCUITS
ALARM
EMERGENCY
UTILITY
ELCD
EMERGENCY LIGHTING
CONTRO L DEVICE
US
Z410153 Rev A