LUBE-MASTER R10
2(21)
Table of Contents
1. INTRODUCTION 3
2. MECHANICAL INSTALLATION 3
3. ELECTRIC INSTALLATION 3
3.1. THE MAIN MODULE 3
3.2. CONNECTION ADAPTER (203 03 17) 5
3.3. LID INDICATOR BOARD (203 03 03) 5
4. CONFIGURATION 6
4.1. CHECK BEFORE CONFIGURATION 6
4.2. ADDRESSING THE TSM 6
4.3. SET-UP MODE 6
4.4. CHANGE ADDRESS [TCM//ADDRESS]6
4.5. RECOMMENDATION FOR SETTING ADDRESSES 7
5. CONFIGURE THE PORTS 7
5.1. CONNECT A TANK TO A PORT [TCM//PORTX/TANK]7
5.2. SET THE MASK [TCM//PORTX/MASK]7
5.3. ANALOGUE SENSOR SETTINGS 8
5.3.1. Set the input signal filter time constant .............................................................................................8
5.3.2. Adjusting the offset ............................................................................................................................8
5.3.3. Adjusting the calibration ...................................................................................................................8
5.3.4. Set sensor full scale ...........................................................................................................................9
5.4. FLUID SPECIFICATION 9
5.4.1. Set fluid name....................................................................................................................................9
5.4.2. Set fluid part number.........................................................................................................................9
5.4.3. Set the fluid density..........................................................................................................................10
5.5. TANK SPECIFICATION 10
5.5.1. Set tank capacity..............................................................................................................................10
5.5.2. Set the tank reorder volume level ....................................................................................................10
5.5.1. Set the tank stop volume level..........................................................................................................11
5.5.2. Set tank bottom area........................................................................................................................11
5.5.3. To configure a TSM port for a tank that does not have a constant area .........................................11
5.6. DISPLAYING TANK CONTENT ON A LED DISPLAY 12
5.6.1. Set LED address ..............................................................................................................................12
5.6.2. Set LED update interval ..................................................................................................................12
5.7. SET THE TYPE OF TANK (PC SYSTEM). 13
6. MENU TREE 14
7. FAST MENU CODES 15
8. TECHNICAL SPECIFICATION 16
9. TO CONNECT DISCRETE LEVEL SENSORS 53132/138/171 AND SOLENOID VALVES 17
9.1. FRESH OIL TANK,53138 (2-LEVELS) 17
9.2. FRESH OIL TANK,53171/53183 (1-LEVEL) 17
9.3. WASTE OIL TANK,53132 (2-LEVELS) 17
9.4. ONE TSM PORT CONTROLS A NUMBER OF PUMPS 18
10. EX-BARRIER 53187 FOR DISCRETE LEVEL SENSORS. 18
10.1. CONNECTING A WASTE OIL TANK 53132 (2-LEVELS) 19
11. TO CONNECT AN ANALOGUE SENSOR 19
11.1. ANALOGUE SENSOR 53417 19
11.2. CONNECTING AN ANALOGUE SENSOR. 20
12. EX-BARRIER 53188 FOR ANALOGUE SENSORS. 20
12.1. CONNECTION 21
13. MPDM PCB MOUNTED IN A TSM BOX 21