Estyma Vide Manuel utilisateur


page 2
PL20130524

Content
Index
1 General information 4
1.1 Introduction 4
1.2 Elements of the set 4
1.3 Precautions 5
1.4 Procedure with the used equipment
2 Connection
2.1 Electrical wiring
2.2 Location 7
condensation. 7
2.3 Installation 7
2.4 Description of connections 8
3 Review of functions 9
3.1 Control of binary output 9
3.2 Information about input condition 9
3.3 Information about the controller of boiler 10
3.3.1 Commands of queries about the parameters of boiler controller.............................10
4 Main display 12
5 Main menu 13
5.1 Sensors 13
5.2 Binary output 14
5.3 GSM settings 15
5.4 Settings 15
5.5 Notices 15
5. Language 1
5.7 Remote control panel 1
Specification 17
estyma electronics
.estyma.pl
page 3
PL20130524

1 General information
1 General information
Than you for choosing our product. We congratulate you on making a good decision. We
elcome any remarks on the operation of device.
Team
ESTYMA electronics
1.1 Introduction
VIDE GSM communication module is a multifunctional device designed for remote
access to the information of module sensors and controller of hot ater boiler by means of
GSM net ork.
The module is equipped ith t o slots of temperature sensors, t o slots for contact
input and output and CAN interface. Configuration, user-friendly panel makes it possible to set
SMS notices about important changes in the operation of sensors, such as:
•exceeding the range of room temperature allo ed
•alarm hen the input contact is closed or open, used for giving notice about the
opening/shutting of doors, gates, garages.
Contact output (binary), makes the remote activation/disconnection of any electrical
equipment possible. Using mobile, you can also read out current parameters of module as ell
as make chnages in settings.
By means of CAN interface, the Vide GSM module can remotely control the operation of
heating controller of IGNEO line, and make changes in the operation modes of boiler, burner
and 16 central heating circuits at most. The GSM communication system makes it possible to
make several changes in the controller operation and to read out current parameters displayed
on your mobile by sending SMS.
1.2 Elements of the set
1. Vide GSM module
2. 2x sensor of room temperature CT2a / 2.4
3. Po er unit
page 4
PL20130524

Content
1.3 Precautions
•Before y
ou start to operate the device, read the hole attached user`s guide carefully.
•Keep the user`s guide and refer to it in case you operate the device in future.
•Observe all the rules and arnings included in the user`s guide.
•Make sure the device is not damaged in any ay. In case of doubt, do not operate the device and
contact the suppier.
•In case of doubt concerning a safe operation of device, contact the suppier.
•Special attention should be paid to arning signs, housing or packaging of device.
•Operate the device according to its intended use.
•The device is not a toy, children should be prohibited from playing ith it.
•On no account can children play ith any part of the packaging of this device.
•
Children should be prevented from accessing small parts, for example, clamping scre s, pins.
These elements can be found on the equipment of device supplied and in
case of s allo ing they
can lead to the choking of child.
•No mechanical or electrical modifications can be made in the device. Such modifications can
cause the rong operation of device, incompatible ith standards or they can influence the
operation of device in a negative ay.
•No objects should be put into the device through gaps (for example ventialtion gaps). This can
cause short circuit, fire or damage to the device.
•Take care that no ater, moisture, dust and dirt gets into the device. This can cause short circuit,
electrical shock, fire or damage to the device.
•Make sure the device is ventilated properly, do not cover ventilation holes and provide a free flo
of air around it.
•The device should be installed inside the rooms.
•Make sure the device is not exposed to impacts and vibrations.
•Connecting the device, make sure that electric parameters of po er supply net ork are ithin
the operation range of device.
•Any connections must be compatible ith the installation electrical iring diagram and ith
national, or local regulations relating to electrical connections.
•There is no part in this device that can be replaced by the user himself. All service operations
except cleaning and setting up the function, should be carried out by the authorized service staff.
•Before starting any maintenance operations, you must absolutely disconnect the device from
po er supply.
•No benzine, solvents or other chemical agents, hich can damage the housing of device can be
used for cleaning the device. A soft cloth is recommended for this purpose.
estyma electronics
.estyma.pl
page 5
PL20130524

1 General information
1. General information
* Any connections must be compatible ith the assembly electrical iring diagram of
installation and national or local regulations as regards electrical connections.
* There is no part in this device, hich the user can replace himself. All service
operations except cleaning or setting up the function, should be carried out only by the
authorized service staff.
* Before starting any maintenance operations, it is absolutely necessary to disconnet
the device from po er supply.
* No benzine, solvents or other chemical agents hich can damage the housing of
device can be used. A soft cloth for cleaning is recommended.
1.4 Procedure with the used equipment
The electronic device as made from materials, hich are fit for recycling only in part.
That is hy, the device must be returned to the recovery and recycling place of electrical and
electronic equipment or handed over to the manufacturer. The device must not be disposed of
ith otehr household rubbish.
2 Connection
2.1 Electrical wiring
Before you start to operate the device, read the hole enclosed user`s guide carefully.
The person ho makes the installation must have technical experience. Connections
made ith the use of copper cable should be adapted to the operation at a temperature of up
to +75ºC.
All the connections must be compatible ith the installation electrical iring diagram
and national or local regulations about electrical connections.
page 6
PL20130524

Content
2.2 Location
The device is intended for the installation only in enclosed spaces. After choosing the
place of installation, make sure it meets the follo ing conditions:
1. The installation place must be free of excessive moisture and flammable vapours or
vapours causing corrosion.
2. The installation of device cannot be made near electrical equipment of high po er,
electrical machines or elding equipment.
3. In the place of installation the temperature of ambient cannot exceed 60ºC and it
should not be lo er than 0ºC. Humidity should range from 5% to 95% ithout
condensation.
2.3 Installation
The module should be mounted on the all in the room selected. There should be a free
air circulation in the place of installation and the place should be a ay from the heating
sources, for example, electronic equipment, fireplace, heater or direct solation. It is
recommended that the module be mounted at a height not less than 1,5 m over the floor.
estyma electronics
.estyma.pl
page 7
PL20130524

2 Connection
2.4 Description of connections
DESCRIPTION OF OUTLETS
Name Description
Po er supply 5V Power (connect the power unit 5V/1.2A)
CAN Communication interface CAN for connecting
the controller of boiler/burner
Binary output Binary output of open collector type Current
efficiency 100mA.
Contact Contact input of open/closed type
T2 Sensor of room temperature T2
T1 Sensor of room temperature T1
page 8
PL20130524

Content
3 Review of functions
3.1 Control of binary output
PIN 1 x;
x – binary output condition [0 lub 1], PIN – number assigned in GSM settings.
3.2 Information about input condition
Query command about the input condition T1, T2, STYK module VIDE GSM:
Example of reply:
estyma electronics
.estyma.pl
page 9
PL20130524

3 Review of functions
3.3 Information about the controller of boiler
Using the mobile you can easily read out or change the parameters of heating controller
from any place.
3.3.1 Commands of queries about the parameters of boiler controller
Command Description
Boiler? Query about the parameters of boiler
Tb – measured temperature of oiler
Tbc – calculated temperature of boiler
Tbsm – temperature of boiler set in the continuous mode
(manual)
Controller – condition of controller (turned ON, turned OFF)
Burner – condition of burner (TURNED OFF, MODULATION)
Boiler mode – mode of boiler operation (MANUAL, AUTO)
Permission – permission for the operation of burner (NO/YES)
Example of replies:
BOILER: Tb 65.5, Tbc 70, Tbsm 65, Controller ON, Burner
MODULATION, Boiler mode AUTO, Permission NO
Water1?
Water2?
Query about the parameters of hot, tap water circuits
Th – mesured temperature of hot ater
Th sc – temperature of comfort hot ater set
Th se – temperature of hot ater set on economy
Program – program of hot ater (TIME, MANUAL, OFF)
Example of replies: (enquiry: Water1?)
page 10
PL20130524
Table des matières
Autres manuels Estyma Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur