Esse-ti GSM300FXS Manuel utilisateur

User’s manual

Thanks for choosing an
Esse-ti product
This product has been especially designed to
manage emergency calls generated in
elevators. It has been manufactured with
perfect workmanship using suitable
materials for long-lasting performance.
All Esse-ti products are subjected to
extensive specific testing in our laboratories
in order to provide total guarantee for the
User.
The User shall be responsible for defects arising from the use of the
product. Esse-ti shall only be responsible for defects according to and
within the limitations set by the Presidential Decree dated 24/05/1988 no.
224 (fulfilling the EEC directive no. 85/374 on the harmonization of
statutory and administrative regulations of the Member States on the
liability for damages arising from defective products under art. 15 of Law
no. 183 of 16 April 1987).
Esse-ti reserves the right to modify the product characteristics at any time
without prior notice.

TABLE OF CONTENTS
GENERAL INSTALLATION INSTRUCTIONS..... 5
General Notes........................................................ 5
Making the installation.......................................... 5
DESCRIPTION......................................................... 6
Features ....................................................................... 6
Optional....................................................................... 6
INSTALLATION...................................................... 7
Inserting the SIM card ................................................ 8
Inserting the antenna ................................................... 8
JP1 Jumper .................................................................. 9
Connection to the telephone line ................................ 9
Connection to the power supply ................................. 9
Turning the GSM300 module on.............................. 10
Module mounting operations.................................... 11
GSM300 installation recommendations ................... 12
Absorption chart........................................................ 12
PROGRAMMING................................................... 13
Use mode ............................................................ 14
Interdigit dialling time ........................................ 14
Dialling codes ..................................................... 15
International call prefix............................................. 15
Country calling code ................................................. 16
CLIP setting ........................................................ 16
CLIR setting........................................................ 18
Permanent setting...................................................... 18
Temporary setting ..................................................... 18
Roaming setting .................................................. 19
Adjustments ........................................................ 20
Transmission ............................................................. 20
Reception .................................................................. 21
Restoring default settings.................................... 21
Reset ................................................................... 22
SERVICES.............................................................. 23
Measuring the signal level .................................. 23
Incoming calls..................................................... 24
Outgoing calls ..................................................... 24
SIGNALS................................................................ 25
Tones................................................................... 25

Call signals.......................................................... 26
LED..................................................................... 26
Status indicator LED (RED) ..................................... 26
GSM Signal indicator LED (GREEN) ..................... 26

Page 5
GENERAL
INSTALLATION
INSTRUCTIONS
GENERAL NOTES
Carefully read the notes contained in this section as they provide
important information on safe correct installation, use and
maintenance of the product.
•The product must be EXCLUSIVELY used for the purpose it
was designed for. Esse-ti shall not be responsible for damages
arising from improper use.
•The product has been designed in compliance with the
regulations in force and must be installed in systems that
comply with the provisions of law.
•Always disconnect power supply before performing internal or
external operations on the product (cleaning, maintenance,
etc.).
•Always refer to an authorized service centre for repair.
•The device must be installed in a ventilated place, making sure
that the ventilation slots are never obstructed.
•Do not install the product in environments with risk of
explosion.
•Make sure that the product has been installed as required.
•Do not introduce objects, liquids or powders inside the
product. Do not use sprays inside the product.
•Packing components (such as plastic bags, foam polystyrene,
etc.) must be kept out of the reach of children because
potentially dangerous.
MAKING THE INSTALLATION
Internal telephone installations must be carried out by
specialised personnel.
The installation and connection of telephone terminals to the
telecommunications network that do not comply with the
regulations in force is not permitted.

Page 6
DESCRIPTION
GSM300 is a device that, connected to a fixed telephone
or to the PSTN input terminals of a PABX or autodialer,
allows you to make and receive calls over the GSM
network.
For correct operation, a normal SIM card is required.
Features
•Dual Band GSM module;
•Connection to normal BCA telephones or to the
PSTN input terminals of a PABX or autodialer;
•Local programming via DTMF tones;
•Display of caller identification;
•CLIP;
•CLIR;
•Roaming setting;
•Measurement of GSM signal level;
•Receiver and transmitter gain adjustment;
•GSM signal indicator LED;
•Status indicator LED;
•External antenna;
•2W transmission power;
•12Vdc power supply input;
•230Vac external adapter input.
Optional
•External adapter (230Vac 50Hz input; 12Vdc
500mA output; CE mark) ;

Page 7
INSTALLATION
A ANTENNA connector
B SIM CARD housing with front panel
C LED indicating signal strength (green) and LED indicating
device operation status (red)
D 12Vdc power supply terminal
E Telephone line output (terminal block)
F 230Vac external adapter input
G Telephone line output (RJ11 connector)
H JP1 Jumper

Page 8
Inserting the SIM card
Before inserting or replacing the SIM card, always
make sure that the module has been disconnected from
the mains and that no electrostatic discharge is present
in order to avoid damaging it. Take all necessary
measures to avoid electrostatic discharge.
¾Shift the SIM card housing cover upward and lift
it.
¾Carefully slide the SIM card in its housing cover.
¾Lower the SIM card housing cover and shift it
downward until it blocks.
WARNING
The SIM Card PIN
must be DISABLED. If
the PIN is enabled, it
must be disabled
through a mobile
phone.
Inserting the antenna
¾Screw the antenna in to the connector on the top
of the module.
¾Attach the antenna to a magnetic surface or use
the bracket supplied.
WARNING
NEVER connect
GSM300 module
without having
previously installed the
antenna. The module
may get damaged.

Page 9
JP1 Jumper
The JP1 jumper (H in the picture at page 7) allows the
variation of the voltage in the TEL terminal and in the
RJ-11 connector (E and G respectively in the picture at
page 7). A higher voltage may be required for the
proper functioning of specific devices.
Position 1: lower voltage
Position 2: higher voltage
Connection to the telephone line
¾Connect the GSM300 to a BCA telephone or to the
PSTN input terminals of a PABX or autodialer via
the RJ-11 connector (G in the picture at page 7);
or
¾Connect the GSM300 to a BCA telephone or to the
PSTN input terminals of a PABX or autodialer
using the TEL terminal (E in the picture at page
7).
Connection to the power supply
Power supply via 230 Vac external adapter
¾Connect the external adapter to its input (F in the
picture at page 7).
¾Close the module cover.

Page 10
or
12 Vdc power supply
¾Connect the power supply cable to the terminal
(D in the picture at page 7) taking care to respect
the polarity.
¾Close the module cover, paying attention to the
power supply cable.
Note: a protection cut-out switch must be
installed upstream to interrupt
power supply in case of fault.
Turning the GSM300 module on
¾Power the GSM300.
¾Make sure that the device operation status (red)
LED turns on and remains on and steady for a few
seconds and then starts flashing.
The steady red LED indicates that the GSM module is
not correctly affiliated to the telephone provider.
Disconnect GSM300 and make sure the SIM card is
inserted correctly and that the PIN is not locking it.
Note: for a correct registration of the
GSM300 module, you must wait 15
seconds after which you can carry
out the programming and make
calls.
Table des matières
Autres manuels Esse-ti Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur