to 15s (test mode), make sure there is no motion, the load should
TROUBLESHOOTING`
The time delay toggle switch is default set on 15 seconds. Do not adjust
By pushing the ON/OFF Button, the load can be turned ON/OFF under
detected. To verify proper operation, turn the time delay toggle switch
-06-
-05-
-04-
This warranty service is available by returning the product with proof
dealer from whom the unit was purchased.
of purchase, purchase date and a description of the problem to the
INSTALLATION INSTRUCTIONS
Manual ON/OFF Button
Turning ON the Load under Occupancy Mode
Load automatically turned ON when occupancy is detected.
Turning ON the Load under Vacancy Mode
Manual ON/OFF button has to be pushed to turn ON the load.
Automatic Turning OFF the Load
Under either mode, the sensor keeps the load ON until no motion is
Manual Turning OFF the Load
By manual ON/OFF button, the load can be turned OFF under either OCC
or VAC mode. Under OCC mode, if you press manual ON/OFF button
either OCC or VAC mode. (illustrated in Figure 5).
detected plus the set time delay, then turns OFF automatically.
Therefore, a
Initial run
The sensor switch needs
During the initial
run, the load might be turned ON and OFF several times.
it until initial run is finished and proper operation function confirmed.
The load is out of control
1. It can take up to one minute for initial run.
2. Check the wiring connections, especially the
The load does not turn OFF
1. There can be up to a 30 minutes time delay after the last motion
initial run for one minute.
2. Check if there is any significant heat source mounted within six feet (two
meters) that may cause false detection such as high wattage light bulb,
portable heater, and HAVC device.
3. Check the wiring connections, especially the neutral wiring to the
The load turns ON when not desired
1. Switch from OCC to VAC mode.
2. Mask the sensor switch’s lens to eliminate unwanted coverage area.
neutral.
Secured Neutral Wiring is required.
Neutral Wiring.
Hot and
turn OFF in 15 seconds.
sensor switch.
TROUBLESHOOTING
May, 2014
Under VAC mode, only after the load automatically turns OFF, the load can
be turned ON automatically if occupancy detected within 30 seconds.
For proper operation, the sensor switch has to consume power from
Figure 5
first ,the sensor switch returns to normal until set-time finished.
The sensor switch is programmed independently for either occupancy
mode or vacancy mode depending on the band switch position on the both
side of top cover. Some might call the vacancy mode as “manual on
OPERATION
occupancy mode”.
WARRANTY INFORMATION
If within two(2) years from the date of purchase, this product fails due
to a defect in material or workmanship, we will repair or exchange it, at
its sole option free of charge. This warranty does not apply to: (a) damage
to units caused by accident, dropping or abuse in handling, acts of god
or any negligent use; (b) units which have been subject to un-authorized
repair, opened, taken apart or otherwise modified; (c) unit not used in
accordance with instruction; (d) damages exceeding the cost of the product;
(e) finish on any portion of the product, such as surface and weathering,
as this is considered normal wear and tear; (g) transit damage, initial
installation costs, removal costs, or rein-installation costs.