Eneo IAM-6SE1008IMA Manuel utilisateur

Quick Installation Guide
Gigabit Switch, Managed,
Layer 3, PoE, SFP 10G,
Industrie Design
IAM-6SE1008IMA
IAM-5SE1016IMA
EN

About this document
This document is Quick Installation Guide. It is intended for engineers or anyone who
needs to install the product.
Announcement
The information in this document is subject to change without notice.
The document is only used as operation guide, except for other promises. No
warranties of any kind, either express or implied are made in relation to the description,
information or suggestion or any other contents of the manual.
The images shown here are indicative only. If there is inconsistency between the image
and the actual product, the actual product shall govern.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
DANGER Indicates a hazard with a high level of risk, which if not
avoided, will result in death or serious injury.
WARNING Indicates a hazard with a medium or low level of risk,
which if not avoided, could result in minor or moderate
injury.
CAUTION Indicates a potentially hazardous situation, which if not
avoided, could result in equipment damage, data loss,
performance degradation, or unexpected results.

Content
Packing List............................................................................................1
Product Introduction..............................................................................2
2.1 Overview ......................................................................................2
2.2 Hardware Introduction..................................................................2
3.1 Safety Precaution.........................................................................6
3.2 Insatallation Steps........................................................................8
3.2.1 DIN-rail Installation.......................................................................9
3.2.2 Wall-mounted Installation .............................................................10
3.2.3 DC Power Cable Connection........................................................11

1
Packing List
Open the box of the product and carefully unpack it. The box should contain the
following items. Please check before installation, if any missing, please contact your
dealer immediately.
No.
Items
Quantity
1
Switch
1 pcs
2
Mounting Accessory
1 set
3
Quick Installation Guide
1 pcs

2
Product Introduction
2.1 Overview
This series product is Industrial 8-Port/16-Port Gigabit PoE + 4-Port 10G SFP+ L3
Managed Ethernet Switch.
This series switch provides 8/16 Gigabit Ethernet RJ-45 ports and 4 10G SFP+ fiber
uplink ports. All RJ-45 ports support Power-over-Ethernet (PoE+) and deliver up to 30W
power per port.
The switch has extensive Layer 2 and Layer 3 management functions, such as VLANs,
IGMP Snooping, QoS, RSTP, Fast Ring or Layer 3 routing. It can be easily managed
via a WEB GUI (http/https), CLI (telnet/ssh/console) or SNMP.
The switch is designed for a wide operating temperature range from -40 to 75 C and
has a redundant power supply.It is equipped with an alarm relay that can be configured
via software.
This series swtiches contain two types:
Industrial 8-Port Gigabit PoE + 4-Port 10G SFP+ L3 Managed Ethernet Switch
(Short for 8-Port PoE Switch)
Industrial 16-Port Gigabit PoE + 4-Port 10G SFP+ L3 Managed Ethernet Switch
(Short for 16-Port PoE Switch)
2.2 Hardware Introduction
Front Panel (8-Port PoE Switch)

3
Front Panel (16-Port PoE Switch)
Left Side Panel (8-Port/16-Port PoE Switch)
Led Indicators Instructions
Indicators
Status
Descriptions
PWR1
DC Power Supply
Indicator (Main)
On
The main power supply is working.
Off
The main power supply is off.
PWR2
DC Power Supply
Indicator (Backup)
On
The redundant power supply is
working.
Off
The redundant power supply is off.

4
SYS
System Working
Indicator
Blink
System is working normally.
On/Off
System failure
ALM
Relay Alarm Indicator
On
The device alarms.
Off
The device is working normally.
Link
Port Link Indicator
On
The port is linking normally.
Blink
The port is transmitting or receiving
data.
Off
The port links down.
PoE
Port PoE Indicator
On
The port is supplying PoE normally.
Off
The port stops supplying PoE.
Power Supply Port
The input power supply port of the switch adopts 2 pcs removable 4-position terminal
blocks. The electrical performance are as follows.
Specifications
Descriptions
Wire range
22~14 AWG (2.5mm²)
Torque
0.4Nm (3.5 Lb.in)
Wire strip length
7~8mm
Dielectric Strength
AC 2000V/1 minute
Rating
300V/10A
Relay Interface
The switch supports relay alarm function.
The input port of the relay interface adopts removable 2-position terminal block. The
electrical performance are as follows.
Specifications
Descriptions
Wire range
22~14 AWG (2.5mm²)
Torque
0.4Nm (3.5 Lb.in)
Wire strip length
7~8mm
Dielectric Strength
AC 2000V/1 minute
Rating
250V/10A

5
The “Relay Interface” could be connected with warner device, such as a buzzer. In the
following three cases, the switch will alarm and the ALM Indicator will turn red.
Alarm cases
Descriptions
Indicators
Power Supply
Off
The main power supply or backup power
supply is off.
In this case, the power supply indicator of
the working power supply is off, please
check the power supply.
Port Network
Disconnected
The linking port is disconected.
In this case, the port link indicator is off,
please check the network cable.
Port PoE Off
The port stops supplying PoE.
In this case, the port PoE indicator is off,
please check the PoE function.
Console Port
The device contains aserial RS-232 interface as the console port for local management
interface. For the console port, a standard RJ-45 connector is used. Use a RS-232
calbe (Sub-D9 to RJ-45) to connect the console port with the COM port of a PC.
Default configuration:
Data
Default value
Transfer rate
115200 bit/s
Flow control
mode
Not support
Test mode
Not support
Stop bits
1
Data bits
8
Init Button
The init button has two operating modes.
By short pressing the button, the switch will be reset and the configuration is as
previous setting saved.
By pressing the button over 5s, the switch will be restored to the original factory
default setting.

6
Installations
3.1 Safety Precaution
To minimize the technically residual risk, it is imperative to obey the following rules.
Read all the instructions before operation.
The Caution, Warning and Danger items in the document does not cover all the safety
precautions that must be followed. They are only supplementary information.
When operating the device, obey the local safety regulations. The safety precautions
provided in the documents are supplementary and shall be in compliance with the local
safety regulations.
Operator
Only qualified and skilled personnel can install, configure, and disassemble the
device.
Only the personnel authorized can operate the device.
Any replacement or change to the device or parts of the device (including the
software) must be done by qualified or authorized personnel.
Any fault or error that might cause safety problems must be reported immediately
to the person in charge.
Ground
For better protection performance, it is recommended as follows.
Do not damage the ground conductor or operate the device in the absence of well
installed ground conductor. Conduct the appropriate electrical inspection.
When operating the unit, always make the ground connection first and disconnect
it at the end.
Human Safety
Do not operate the device or cables at lightning strikes.
If the device is designed with optical port, do not look directly into the optical port to
prevent the laser radiation from injuring your eyes.
Do not wear jewelry or watches when you operate the device.
Equipment Safety
Before operation, the device must be fixed securely on the floor or to other reliable
objects, such as the desktop, the walls or the mounting racks.
Do not block the ventilation while the device is running. Keep a minimum distance
of 5 cm from the ventilation to the walls or the other objects that block the ventilation.
Tighten the thumbscrews by using a tool after both initial installation and
subsequent access to the panel.

7
Inflammable Environment
DANGER
Do not place the device in the environment that has inflammable and explosive air
or fog. Do not perform any operation in this environment.
Operating the electrical device in inflammable environment can be fatal.
Moisture Proof
WARNING
Water or moisture in the equipment will damage the circuit of the equipment.
The installation environment of the equipment must be strictly prohibited from water
seepage, dripping, and condensation, otherwise it is necessary to install
dehumidification equipment (such as air conditioners with dehumidification function,
special dehumidifiers), etc.
It is forbidden to operate the equipment under or near the water source, such as
the sink, laundry room or other high humidity areas.
It is forbidden to touch the device with wet hands.
Dust Proof
Install the equipment far away from sand and dust sources, such as coal mines,
rural roads, and farmland, etc.
It is forbidden to operate the device in a dense dust environment.
Ventilation
WARNING
Operating equipment will release heat. Please ensure that the environment where
the equipment is installed is well ventilated to ensure the equipment operating
normally.
It is strictly forbidden to install the equipment near heat sources, such as stoves,
heaters, etc.
Ensure that the equipment installation environment has good air flow.
If the equipment is designed with heat dissipation holes, it is strictly prohibited to
block the heat dissipation hole of the device.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Eneo Changer

Eneo
Eneo IAM-5SE1004MUD Manuel utilisateur

Eneo
Eneo IAR-7SE2016MMA Manuel utilisateur

Eneo
Eneo IAR-7SE2024MMA Manuel utilisateur

Eneo
Eneo IAR-7SE1024MMC Manuel utilisateur

Eneo
Eneo IAM-5SE1004MUC Manuel utilisateur

Eneo
Eneo EPS-1016 Instructions d'installation

Eneo
Eneo IAM-5SE1004MUC Manuel utilisateur

Eneo
Eneo IAM-5SE1004MUB Manuel utilisateur

Eneo
Eneo DS-4 Manuel utilisateur

Eneo
Eneo IAD-5SG1004MUC Manuel utilisateur