Elsys ELT-2 Manuel utilisateur

Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Specifications in this document are subject to change without notice.
©Elektroniksystem i Umeå AB 2020
www.ime.de

2
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Important safety information
Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be
dangerous or cause a violation of the law. The manufacturer, Elektroniksystem i
Umeå AB will not be held responsible for any loss or damage resulting from not
following the instructions of this operating manual.
•The device must not be dismantled or modified in any way.
•The device is not intended to be used as a reference sensor, and
Elektroniksystem i Umeå AB will not be held liable for any damage which
may result from inaccurate readings.
•The battery should be removed from the device if it is not to be used for
an extended period. Otherwise, the battery might leak and damage
the device. Never leave a discharged battery in the battery
compartment.
•The device must never be subjected to shocks or impacts.
•To clean the device, wipe with a soft moistened cloth. Use another soft,
dry cloth to wipe dry. Do not use any detergent or alcohol to clean the
device.
Disposal note in accordance with ElektroG and WEEE Directive
2012/19/EU
The device, as well as all the individual parts, must not be disposed of
with household waste or industrial waste. You are obliged to dispose of the
device at the end of its service life in accordance with the requirements of
ElektroG in order to protect the environment and to reduce waste through
recycling. For additional information and how to carry out disposal, please
contact the certified disposal service providers. The sensors contain a lithium
battery, which must be disposed of separately.
www.ime.de

3
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Contents
Important safety information.......................................................................................................... 2
Description......................................................................................................................................... 5
Main features of ELT-2 HP........................................................................................................ 6
Installation.......................................................................................................................................... 7
Installing external sensors ......................................................................................................... 8
External temperature sensor................................................................................................ 8
Analog input 0 –3 or 0 –10 Voltage............................................................................... 8
Powered analog input 0 –10V........................................................................................... 9
Switch Input (Pull up) ........................................................................................................... 9
Pulse count (Pull up) ..........................................................................................................10
Pulse count (Pull down) .....................................................................................................10
Pulse count (Pull down) –External pulse.......................................................................11
Pulse count (Pull up) –S0 input ......................................................................................11
4 –20 mA input...................................................................................................................12
Water leak input....................................................................................................................12
Maxbotix distance sensor input.........................................................................................13
Meter (Decagon) sensor input .........................................................................................13
Pulse count (Pull up) –2 channels..................................................................................14
Pulse count (Pull down) –2 channels ............................................................................14
Switch input + Temperature sensor.................................................................................15
Sensor configuration......................................................................................................................16
NFC Configuration.....................................................................................................................16
Over the air configuration ........................................................................................................17
Application parameters.............................................................................................................17
Sensor behavior..............................................................................................................................17
www.ime.de

4
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
NFC Read / Write ......................................................................................................................17
Sensor startup ...........................................................................................................................18
Sampling mode / Periodic measurement .............................................................................19
Schedule Transmission.............................................................................................................19
External sensors ........................................................................................................................20
Specifications ..................................................................................................................................21
Sensor payload format .............................................................................................................21
Regulations......................................................................................................................................22
Legal Notices .............................................................................................................................22
Declaration of conformity ........................................................................................................22
www.ime.de

5
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Description
ELT-2 is a universal outdoor device for LoRaWAN® wireless network. It is
designed to be in extreme conditions and can measure analog or digital signals.
Use it together with electricity meters, flow meters, analog sensors, moisture
sensors and other external sensors. ELT-2 is enclosed in an IP67 box and have
four internal sensors: temperature sensor, humidity sensor, accelerometer and an
atmospheric pressure sensor. This is a battery-powered device equipped with
NFC (Near Field Communication) and can easily be configured from a
smartphone.
The barcode contains DevEUI and sensor type. This label is located at the back
of your device,
ELT-2-HP
www.ime.de

6
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Main features of ELT-2
•Compatible with LoRaWAN® specification 1.0.3
•Measures ambient temperature
•Measures ambient humidity
•Measures ambient atmospheric pressure
•Detects acceleration
•Analog 0 –10 V input
•Digital input
•Direct connection to various external sensors and equipment
•Easy installation
•Easy configuration
•IP67 Classified
•Battery-powered
•Long-range communication
•Configurable over NFC
•Configurable over the air
•Ten years of battery life*
•Supported channel plans: US902-928, EU863-870, AS923, AU915-
928, KR920-923, RU864, IN865 & HK923
•CE Approved and RoHS compliant
*Depending on settings and environmental factors
www.ime.de

7
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Installation
1. Remove the front lid of the sensor by removing the four screws.
2. Install the battery. The ELT-2 requires one AA battery. The battery type
is 3.6V Lithium Battery (ER14505).
Caution: Using batteries other than the ones provided may result in loss of performance
and battery life, and also damage to the device. Dispose of properly, observing
environmental protection rules.
3. Connect any eventual external sensors.
4. Close the lid and tighten the screws carefully. Make sure that the cable
gland and antenna connection is tightened to prevent ingress of
moisture.
5. Mount the device by using the two holes on the sides.
www.ime.de

8
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Installing external sensors
External temperature sensor
Configured for 1-wire interface. Connect a DS18B20 compatible sensor. Select
“Temperature sensor 1 wire” in the application “Sensor Settings”. ELT input is internally
pulled up by 2.2kΩ.
Analog input 0 –3 or 0 –10 Voltage
Input signal between input and ground.
Select “Analog input 0-3V” or ”Analog input 0 – 10V” in the application “Sensor
Settings”. ELT input is internally pulled down.
/ 0-10V
/ 0-10V
www.ime.de

9
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Powered analog input 0 –10V
Input signal between input and ground. +3V present at B+ pin.
Select “Analog input” in the application “Sensor Settings”. Select “Eternal startup time”
and configure ON-time for sensor. External startup time is how long the sensor will be
powered before sampling value. ELT input is internally pulled down and the input
impedance is 7.4 kΩ
Switch Input (Pull up)
Input signal between input and ground.
Select “Switch (Normally open)” in the application “Sensor Settings”. ELT input is
internally pulled up by ~50 k Ω*.
www.ime.de

10
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Pulse count (Pull up)
Input signal between input and ground.
Select “Pulse input (pull up)” in the application “Sensor Settings”. ELT input is internally
pulled up by ~50 k Ω*.
Pulse count (Pull down)
Input signal between input and B+.
Select “External startup time” in the application “Sensor Settings” and configure ON-time
for always on that is >1000000ms.
Select “Pulse input(pull down)”. ELT input is internally pulled down by ~50 kΩ*.
www.ime.de
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Elsys Accessoires

Elsys
Elsys ERS Manuel utilisateur

Elsys
Elsys ERS2 Series ERS2 Lite Manuel utilisateur

Elsys
Elsys EMS Series Manuel utilisateur

Elsys
Elsys ECO Series Manuel utilisateur

Elsys
Elsys EMS Door Manuel utilisateur

Elsys
Elsys ELT-2 HP Manuel utilisateur

Elsys
Elsys ERS Eye Manuel utilisateur

Elsys
Elsys ERS CO2 Manuel utilisateur

Elsys
Elsys ERS Manuel utilisateur

Elsys
Elsys EMS Desk Manuel utilisateur