2
FOR SAFETY REASON A SAFETY DEVICE MUST BE USE WHEN USING THIS REMOTE CONTROL !!!
TERMINALS CONNECTIONS :
1-2 Antenna, terminal n°2 = RF 15-14 “Start/Stop” push button (n.o. contact)
3-4 Input from intercom 12Vac see <T> 16-14 SS2 push button motor n 2 command
5-6 Closing limit switch (n.c. contact)
see <D> 17-18 Electric - lock 12vac-15w
7-5 Opening limit switch (n.c. contact)
see <D> 18-19 24Vac output (max 3 pairs of photocell)
8-5 ‘’open’’ push button (n.o. contact)
or Magnetic Detect 20-21 POWER SUPPLY 230V-50Hz
9-10 ‘’close’ ’push button (n.o contact) 22-23 Flashing light 230V -25w
11-10 Photocell n 2 (n.c. contact) or
rubber see logic <H> 24-25 Courtesy light contact ( free voltage)
12-10 Photocell n 1 (n.c. contact) 26-27-28 Motor n 1 (terminal N.27 = com.)
13-14 “Stop” push button (n.c. contact) 29-30-31 Motor n.2 (terminal. N.30 = com.)
LED FUNCTIONS
ON Normally ON POWER ON BOARD
OK 1 flashing when a radio code is
received and recognized
During programming
1 flashing when a code is
memorized
3flashing = error, the code
received is already in memory
or memory is full
ON, during motor timing
programming
ON, during pause timing
programming
ON, during RESET
Flashing when the RESET has
been execute
M1 ON, when motor n 1 is activated
M1rev Show the direction of motor n 1
M2rev Show the direction of motor n 2
M2 ON, when motor n 2 is activated
Elett ON, when electric-lock is activated
Ped ON, when SS2 button is pushed
Start ON, when START button is pushed
Stop Normally ON it turns OFF when STOP
button is pushed
Fot1 Normally ON it turns OFF when the
photocell n 1 ray is interrupt
Fot2 Normally ON it turns OFF when the
photocell n 2 ray is interrupt
Apre ON, when OPEN button is pushed
Chiude ON, when CLOSE button is pushed
Fa1 Normally ON it turns OFF when the
open limit switch is activated
Fc1 Normally ON it turns OFF when the
close limit switch is activated
DIPS SWITCH:
DIP SWITCH ‘’A’’ DIP SWITCH ‘’B’’
A1 Pre-flashing -- L -- B1 Electric-lock -- N --
A2 Walk-way 45° -- M -- B2 Motor phase reverse – G --
A3 Logic 0 -- H -- B3 In ON position = motor delay erased
A4 Logic 1 -- H -- B4 In ON position = slow-down erased
A5 Pause time activated B5 In ON position = locking for wind – P -
A6 Pause time program – E -- B6 Open gate signal – Q --
A7 M1 timing program – B -- B7 Courtesy lamp = 2 seconds – R --
A8 M2 timing program – B -- B8 Courtesy lamp code program – A4 --
A9 Start code program – A1 -- B9 Soft motor Start – S --
A10 ERASE – I -- B10 Walk-way code program – A7 --
YOU CAN USE WITHOUT PROGRAMMING…… ! -
The control board is supplied with a BASI PROGRAM that give you the following functions :
¾Motors timing : 20 seconds –slow-down excluded
¾Pause time : 30 seconds
¾Delay time : 5 seconds in closing and 2 seconds in opening
¾Courtesy lamp time : 3 minutes
¾Radio code in memory: channel n 1 ASTER with dips 1,3,5,7,9 = ON = BASIC CODE.