Easy-Laser E540 Manuel utilisateur

MANUAL
English
05-0584 Revision 2.0
System version 6.0
E540
www. .com information@itm.com1.800.561.8187

www. .com information@itm.com1.800.561.8187

CONTENT
INTRODUCTION 1
Service and calibration 3
Travelling with your measurement system 4
DISPLAY UNIT 5
Navigation buttons 6
OK buttons 6
Function buttons 6
Status bar 7
Screen dump 8
LED lights 8
Battery 9
Charge the Display unit 9
Charge measuring units 9
Calculator 10
Measurement le handling 11
Save le 11
File manager 11
Open le as template 12
Copy le to USB memory 12
Barcode 12
Print le (Optional) 13
Report 13
Download le to PC 13
Control panel 14
Filter 14
Unit and resolution 15
Detector rotation 15
Date and time 15
Language 16
User 16
Backlight 16
Automatic power off 17
VGA 17
System update 18
License 19
Bluetooth® set up 20
CHOOSE PROGRAM 23
Preparations 23
www. .com information@itm.com1.800.561.8187

PROGRAM VALUES 25
Tolerance 26
Zoom 26
Half or Zero set value 27
Live values – colours 27
Automatic recording 28
Streaming values 29
Calibration check 30
HORIZONTAL 31
Mount the units 32
Connect cables or Bluetooth® units 32
Cable 32
Enter distances 34
Measure using Easy Turn™ 35
Measure using 9-12-3 36
Result and adjust 37
Live values 38
Thermal compensation 40
RefLock™ 41
Tolerance 42
MACHINE TRAIN (3) 45
Enter distances 46
Measure using EasyTurn™ 47
Measure using 9-12-3 48
Result 49
Result Machine view 49
Result Table view 50
Result Graph view 51
Lock feet pair 52
Best t and Manual t 52
Uncertain coupling 52
Adjust 53
Tolerance 55
Thermal compensation 56
SOFTFOOT 57
VERTICAL 59
Preparations 59
Measure 60
Result 61
Adjust machine 62
BTA 63
Preparations 64
Mount the units 64
Enter distances 65
Measure 66
VIBROMETER 69
Measure 70
Vibration level 71
Bearing condition value 72
TECHNICAL DATA 73
Display unit E52 74
Measuring units 75
BTA E170 (Optional) 76
Vibrometer (Optional) 77
INDEX 79
www. .com information@itm.com1.800.561.8187

1
INTRODUCTION
Damalini AB
Damalini AB develops, manufactures and markets Easy-Laser®measurement and
alignment equipment based on laser technology.
We have more than 25 years of experience from measurement tasks in the eld and
product development. We also provide measurement service, which means that we
ourselves use the equipment we develop, and continuously improve it. Because of this
we dare to call ourselves measurement specialists.
Do not hesitate to contact us about your measurement problems. Our expertise will
help you solve it in an easy way.
Declaration of conformity
Equipment: Easy-Laser®product range
Damalini AB declares that the Easy-Laser®product range is
manufactured in conformity with national and international regulations.
The system complies with, and has been tested according to the
following requirements:
EMC Directive 2004/108/EG
Low Voltage Directive 2006/95/EC
Laser Classication EN-60825-1 and complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser Notice No. 50,
dated June 24, 2007.
RoHs Directive 2002/95/EG
WEEE Directive 2002/96/EG
For Bluetooth®devices: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Disposal of old electrical and electronic equipment (Applicable through-
out the European Union and other European countries with separate col-
lection programs)
This symbol, found on product or on its packing, indicates that this prod-
uct should not be treated as household waste when disposed of.
It should be handed over to an applicable collection point for the re-
cycling of electrical and electronic equipment. By ensuring this product is disposed
correctly, you will help to prevent potential negative consequences to the environment
and human health. For more detailed information about the recycling of this product,
please contact your local city ofce, household waste disposal service or the retail
store where you purchased this product.
Quality certicate
Damalini AB is ISO 9001:2008 certied. Certicate number 900958.
Damalini AB conrm, that our products are produced according to applicable national
and international regulations and standards. All components are checked before assem-
bly and nal products are tested in functionality and visually checked before delivery
The calibration of the equipment fully complies with ISO9001: 2008 #7.6
www. .com information@itm.com1.800.561.8187

2
Introduction
Limited warranty
This product is manufactured under Damalini’s strict quality control system. Should
the product fail within two (2) years from the date of purchase under normal usage
conditions, Damalini will repair or replace the product free of charge.
1. Using new or refurbished replacement parts.
2. Exchange the product with a product that is new or which has been manufactured
from new or serviceable used parts and is at least functionally equivalent to the
original product.
Proof of purchase date should be conrmed, and sent together with a copy of the origi-
nal purchase document.
Warranty is valid under normal usage described in the user’s manual appended with
the product. The warranty comprises failure on Easy-Laser®product that could be
related to material and/or fabrication errors. The warranty is valid only in the country
of purchase.
The warranty is not valid in the following cases:
• If the product is broken due to mishandling or incorrect operation
• If the product has been exposed to extreme temperature, calamity, chock or high
voltage.
•If the product has been modied, repaired or disassembled by unauthorized per-
sonnel.
Compensation for possible damage due to failure on Easy-Laser®product is not in-
cluded in the warranty. Freight cost to Damalini is not included in the warranty.
Note!
Before delivery of the product for warranty repair, it is the responsibility of the buyer
to backup all data. Data recovery is not included in the warranty service and Dama-
lini is not responsible for data that may be lost or damaged during transit or repair.
Lithium Ion battery limited warranty
Lithium ion batteries inevitably lose power during their lifetimes, depending on usage
temperatures and the number of charging cycles. Therefore, the internal rechargeable
batteries used in the E-series are not included in our general 2-year warranty. There
is a 1 year warranty for the battery capacity not to fall below 70 % (a normal change
means that the battery must have more than 70 % capacity after more than 300 charg-
ing cycles). A 2 year warranty applies if the battery becomes unusable because of a
manufacturing fault or factors that Damalini AB could be expected to have control of,
or if the battery displays abnormal loss of capacity in relation to use.
Extended warranty
Easy-Laser® Measurement and Alignment Systems meet the highest quality standards!
For this reason, we have extended the warranty to you to a total of 3 years — free of
charge!
The prerequisite for a warranty extension is that you register your system parts on
the Internet within 6 months of purchase. The warranty period begins on the date of
purchase. The warranty extension applies to all products in accordance with the Easy-
Laser® Warranty requirements.
www. .com information@itm.com1.800.561.8187

3
Introduction
Safety precautions
Easy-Laser®is a laser instrument in laser class II
with an output power less than 1 mW, which
requires the following safety precautions:
• Never stare directly into the laser beam
• Never aim the laser beam at anyone else’s eyes.
Note!
Opening the laser units can result in hazardous radiation, and will invalidate the
manufacturer warranty.
If starting the machine to be measured would result in injuries, the possibility to un-
intentionally start it must be disabled before mounting the equipment, for example by
locking the switch in the off position or removing the fuses. These safety precautions
should remain in place until the measurement equipment has been removed from the
machine.
Note!
The system should not be used in explosive risk areas.
Service and calibration
Our Service centres will quickly assist you if your measurement system need to be
repaired or when it is time for calibration.
Our main Service centre is located in Sweden. There are several local Service centres
that are certied to carry out limited service and repair. Contact your local Service
centre rst before sending your equipment for service or repair. All Service centres are
listed on our web site under Service and Calibration.
Before sending your measuring system to our main Service centre, please ll in the
online Service and Repair report. www.easy-laser-service.com
Manuals as PDF
You can download our manuals in pdf format from our website. The pdf’s are also
available on the USB memory stick that is delivered with most systems.
EasyLink
The new version of our database program EasyLink is available on the USB memory
stick that is delivered with most systems. You can always download the latest version
from damalini.com>download>software.
www. .com information@itm.com1.800.561.8187

4
Introduction
Travelling with your measurement system
When travelling by airplane with your measurement system we strongly recommend
that you check which rules apply for each airline company. Some companies/countries
have limitations for checked baggage when it comes to items including batteries. For
information about Easy-Laser® batteries, please see system unit details in the end of
this manual. It is also good practice to remove the batteries from the equipment, when
possible, e.g. D22, D23 and D75.
Compatibility
The E-series is not compatible with previous analogue units from the D-series. You can
however continue to use previous brackets.
Disclaimer
Damalini AB and our authorized dealers will take no responsibility for damage to
machines and plant as a result of the use of Easy-Laser®measurement and alignment
systems.
Copyright
© Damalini 2013
We might change and correct the manual in later issues without further information.
Changes to the Easy-Laser®equipment may also affect the accuracy of the informa-
tion.
September 3 2013
www. .com information@itm.com1.800.561.8187

5
DISPLAY UNIT
Press and hold the On/Off button to reset the Display unit.
DA B C
Navigation buttons
Function buttons
Numeric buttons
LED signals
OK buttons
AConnection for external power.
BUSB A (master). Use for USB memory.
CUSB B (slave). Use for connecting to a PC.
DConnection for Easy-Laser® equipment.
www. .com information@itm.com1.800.561.8187

6
Display unit
Navigation buttons
To navigate on the screen, use the navigation buttons. The selected icon is marked with
a yellow frame. The navigation buttons are also used to move between the icons in a
submenu and to change the values in the elds.
Navigation buttons
Numerical buttons
OK button
Function buttons
OK buttons
There are two green OK buttons and they both work in the same way. Press to
select the currently selected icon for example.
Function buttons
The icons above the function buttons change depending on which view is currently
displayed on screen.
Below is a list of the most common icons.
Back to previous view. Press and hold to leave current program.
Back. There is no “previous view”. Leave the current program.
More. Contains a submenu with general functions,
such as (Control panel) and (Save le).
Submenus
The icons formed as an arrow contain a submenu. Use the navigation buttons to navi-
gate in a submenu. Press to select.
Function button with arrow contains submenu
www. .com information@itm.com1.800.561.8187
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur











