Duratech LINK Driver PLP-REM-350 Manuel utilisateur

English....................Page 3
Nederlands.......Pagina 21
Français...............Page 39
Deutsch...............Seite 57
Español.............Página 75
PLP-REM-350
Manual
LINK Driver
17-11-20

2

3
ENG
Table of contents
Technical specifications
General Specifications
PLP-REM-350 overview
Logic board
Installation Instructions
Single PLP-REM-350 unit
Multiple PLP-REM-350 installation
Operation modes
DIP switch functionalities
Transmitter functions
Operation mode: PLC
Operatio mode: ON/OFF
Replacing transmitter keypad
Pairing the handheld transmitter
DMX 512 communication
Single PLP-REM-350 unit
Multiple PLP-REM-350 installation
RS-485 communication
Single PLP-REM-350 unit
RS-485 command set
RESET procedure
Transmitter battery
Troubleshooting
Pool light wiring instructions
Wiring remark
Page 4
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 10
Page 11
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 16
Page 17
Page 18
Page 20
...........................................................
.........................................................
..............................................................................
.....................................................
......................................
..................................................................................
....................................................................
............................................................
........................................................
...............................................
.........................................
.....................................................
.....................................
.....................................................
...........................................................................
...................................................................................
.................................................................................
.....................................................................................
..............................................................
.........................................................................................

4
Technical specifications
General specifications
Input Voltage: 230 VAC 50Hz
Output Voltage: 12 VAC
Transformer VA rating: 350VA
Max output Power: 350 VA (12 VAC / 25A)
Max rating relay contact A &B 16A / 250 VAC
Max switching power A & B 4000VA
RF band 868 MHz
Ambient Air Temperature: 0°C to +40°C
Humidity 10% to 90% RH - non condensing
Ingress protection rate: IP54
IEC Protection Class: Class II
PLP-REM-350 overview
12 VAC
Transformer
Integrated toroïdal
Transformer 350VA
Circuit breakers
Logic board
For details:
see next page
12VAC connection
terminals
To connect the pool
lights
PLP-REM-350

5
ENG
Logic board
DMX Address dial
To choose the
DMX start address
CAN bus
12VAC connection
terminals
To connect the pool
lights
DIP switch
To select controller functionalities
RS-485
connection
To connect to
home automation
system
(see page 16)
SD card slot
For firmware updates
DMX input/outpout
The PLP-REM can act
as a DMX receiver with
DMX passthrough
A/B output
For auxiliary circuits
Acts as a SPST
(single-pole, single-
throw) switch
Status LED’s:
(1) General status
Green = OK
Red = error overvoltage or overcurrent
(2) Pairing / RESET status
(3) 12VAC to Pool lamps (Green = ON)
(4) Switch A (Green = ON)
(1)
(2)
(3)
(5)
(4)
(8)
(6)
(7)
(5) Switch B status (Green = ON)
(6) CAN status
(7) RS-485 signal
(8) DMX signal
Pairing / RESET
button
DuraLink RF board
For wireless communication
DuraLink

6
Installation Instructions
Single PLP-REM-350 unit
.Connect a 230VAC power source to the 230VAC terminals of the
PLP-REM-350. Connect the pool lights to the 12VAC connection terminal
block in the PLP-REM-350.
.The PLP-REM-350 has a 350VA transformer built in. The total power load
of pool lights (+ cable losses) may not exceed this.
230VAC
Connect the pool
lights to the 12VAC
terminals
Connect the
230VAC power
source to the
circuit breaker
PLP-REM-350

7
ENG
230VAC
230VAC230VAC
Multiple PLP-REM-350 installation
For extended installations (total lamp power > 350VA), multiple PLP-REM-
350’s can be linked together. This way, a perfect synchronisation of all pool
lights is still guaranteed.
The PLP-REM-350’s need to communicate with each other, to ensure all the
lamps are in perfect sync.
Connect the PLP-REM-350’s with each other using the CAN bus:
Connect the CAN terminals of the first PLP-REM-350 with the CAN terminal
of the second PLP-REM-350*.
If more than 2 PLP-REM-350’s are necessary, simply daisy chain each CAN
terminal with the one from the next PLP-REM-350 (see below).
Respect the polarity of the terminals! (CAN L & H)
Next, set the DIP switches on the PLP-REM-350’s to the correct MASTER/
SLAVE setting. The first PLP-REM-350 will be the MASTER. All the others will
be SLAVE’s. Refer to page 9 for Master/Slave DIP switch info.
CAN BUS
set as MASTER set as SLAVE set as SLAVE
* We recommend using a shielded twisted pair cable (min. 0,5mm² - up to 200m) to connect
multiple PLP-REM-350’s using the CAN bus.
In a Master/Slave setup, only the PLP-REM-350 that is set as MASTER
will react to transmitter commands. Any additional transmitters will
need to be paired with this MASTER PLP-REM-350
!
PLP-REM-350
PLP-REM-350 PLP-REM-350

8
ON/OFF PLC
Compatible lamps
Switch lamps ON/OFF YES YES
Change lamp color YES(1) YES(1)
Operate Relay A & B YES YES
Dimming lamps NO YES(1)
DMX control NO YES
RS-485 control YES(2) YES
Dip switch setting DIP 1 ON DIP 1 OFF
Remote keypad type(3)
Operation Modes
The PLP-REM-350 controller has 2 main operation modes:
“ON/OFF control mode” & “PLC control mode”. Each mode has it’s own
functionalities:
1) Only for RGB lamps
2) In ON/OFF control mode, only a few RS-485 commands are available (see p 15)
3) Depending on which control mode is selected, the keypad of the transmitter needs
to be changed

9
ENG
DIP switch functionalities
The DIP switch on the main circuit board of the PLP-REM-350 allows the
user to customise the way the PLP-REM-350 operates.
* Fast DMX setting
Only for Adagio Pro lamps from 2018 and onwards
DIP SWITCH
function setting 1 2 3 4 5 6
Operation Mode ON/OFF ON
PLC OFF
Relay A PULSE mode ON
TOGGLE mode OFF
Relay B PULSE mode ON
TOGGLE mode OFF
Fast DMX setting * FAST ON
STANDARD OFF
DMX NO LOOP ON
LOOP OFF
MASTER/SLAVE mode SLAVE ON
MASTER OFF
ON position
OFF position
CAUTION: Always switch o the main power supply to the
PLP-REM-350 before changing the DIP switches
PLP-REM-350

10
Transmitter functions
Short push (< 1 sec):
Toggle all lamps ON or OFF
Short push:
Go to next color program
Long push:
Auto sync procedure (3)
OPERATION MODE: PLC (default mode)
Short push:
Toggle output A ON/OFF
Long push:
/
Short push:
Toggle output B ON/OFF
Long push:
/
Short push (< 1 sec):
Toggle all lamps ON or OFF (1)
Long push (> 2 sec(2)):
All lamps & “12VAC TO LAMPS” relay are turned OFF (1)
Short push:
Go to next color program
Long push:
Toggle output A ON/OFF
Short push:
Go to the previous color program
Long push:
Toggle output B ON/OFF
Short push:
Select next dimming level:
100% -- 50% -- 25% ---> 100% -- ...
Long push:
Set lamps to Program 1 (blue) & full brightness
(1) Lamp ON or OFF status is memorized after power down
(2) The green LED in the transmitter will light up as soon as you start pressing a button, and will stop
after 2 seconds, so you know exactly when to release the button.
(3) The lamps will be turned o for 30 seconds and then switched ON/OFF 3 times. This will set all
lamps to program 1: blue
OPERATION MODE: ON/OFF
Table des matières
Langues :
Autres manuels Duratech Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur












