10/23
Technical Reference ...........................................2-4
General Information ............................................... 5
Installation ..........................................................6-7
Lighting & Power Supplies..................................8-9
Pre-Power Checklist ............................................10
Heat Controls & Settings .............................. 11-12
Case Cleaning ......................................................13
Parts Ordering ......................................................14
Appendices
Table of Contents
To ensure proper functionality and optimum performance, it is STRONGLY recommended that Hillphoenix specialty cases be installed/serviced by quali•ed tech-
nicians who have experience working with commercial refrigerated display merchandisers and storage cabinets. For a list of Hillphoenix-authorized installation/
service contractors, please visit our website at www.hillphoenix.com.
PF-H/DELI
MULTI-DECK MERCHANDISER
I N S TA L L AT I O N & O P E R AT I O N S M A N U A L

ii

LIABILITY NOTICE
For Cases with Shelf Lighting Systems
Hillphoenix does NOT design any of its shelf lighting systems or any of its display cases with shelf lighting
systems for direct or indirect exposure to water or other liquids. The use of a misting system or water hose
on a display case with a shelf lighting system, resulting in the direct or indirect exposure of the lighting
system to water, can lead to a number of serious issues (including, without limitation, electrical failures,
•re, electric shock, and mold) in turn resulting in personal injury, death, sickness, and/or serious property
damage (including, without limitation, to the display itself, to the location where the display is situated
[e.g., store] and to any surrounding property). DO NOT use misting systems, water hoses or other devices
that spray liquids in Hillphoenix display cases with lighted shelves.
If a misting system or water hose is installed or used on a display case with a shelf lighting system, then
Hillphoenix shall not be subject to any obligations or liabilities (whether arising out of breach of contract,
warranty, tort [including negligence], strict liability or other theories of law) directly or indirectly resulting
from, arising out of or related to such installation or use, including, without limitation, any personal injury,
death or property damage resulting from an electrical failure, •re, electric shock, or mold.
P079211M, REVO
iii

Important
D A N G E R
▲
Indicates an immediate threat of death or seri-
ous injury if all instructions are not followed
carefully.
At Hillphoenix®, the safety of our customers and employees, as well as the ongo-
ing performance of our products, are top priorities. To that end, we include impor-
tant warning messages in all Hillphoenix installation and operations handbooks,
accompanied by an alert symbol paired with the word "DANGER", "WARNING", or
"CAUTION".
All warning messages will inform you of the potential hazard; how to reduce the
risk of case damage, personal injury or death; and what may happen if the in-
structions are not properly followed.
W A R N I N G
Indicates a potential threat of death or serious
injury if all instructions are not followed care-
fully.
▲
C A U T I O N
Indicates that failure to properly follow instruc-
tions may result in case damage.
▲
iv

Revision History
• new manual format_09/21
• technical reference_01/23
• technical reference, LED lighting, heat control settings and parts list_07/23
• controller parameter update_1-23
v

TECHNICAL REFERENCE
ENGINEERED FOR STORES WITH AMBIENT
CONDITIONS NOT TO EXCEED 75° AND 55%
RELATIVE HUMIDITY. DUE TO ENGINEERING
IMPROVEMENTS SPECIFICATIONS MAY CHANGE
WITHOUT NOTICE. ALL MEASUREMENTS ARE
TAKEN PER ASHRAE-72 SPECIFICATIONS.
NUMBERS ARE BASED ON STANDARD CASE SIZES.
CONSULT ENGINEERING.
PF-H
Self-Service Open Muti-Deck Merchandise
r
4', 6' & 8' (Deli)
PF-H
Rev. Date Rev. # Rev. Title
07-24-23 7 DATE UPDATE
03-15-22 6 DATE UPDATE
SHIPPING WEIGHT
Case Weight
PF-H ---
GENERAL NOTES:
• "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time.
2

TECHNICAL REFERENCE
ENGINEERED FOR STORES WITH AMBIENT
CONDITIONS NOT TO EXCEED 75° AND 55%
RELATIVE HUMIDITY. DUE TO ENGINEERING
IMPROVEMENTS SPECIFICATIONS MAY CHANGE
WITHOUT NOTICE. ALL MEASUREMENTS ARE
TAKEN PER ASHRAE-72 SPECIFICATIONS.
NUMBERS ARE BASED ON STANDARD CASE SIZES.
CONSULT ENGINEERING.
PF-H
Self-Service Open Muti-Deck Merchandise
r
4', 6' & 8' (Deli)
PF-H
Rev. Date Rev. # Rev. Title
07-24-23 7 DATE UPDATE
03-15-22 6 DATE UPDATE
NOTES:
• "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time.
SELF-SERVICE DATA
Case
Length
Heaters Shelves
Bottom
Heaters
First Top
Shelf
Second Top
Shelf
Third Top
Shelf
Qnty
Watts
(Each) Qnty
Watts
(each) Qnty
Watts
(each) Qnty
Watts
(each)
4' 1 1153 1 700 1 815 1 925
6' 2 846 2 515 2 600 2 680
8' 2 1153 2 700 2 815 2 925
ELECTRICAL DATA
Case
Length
Fans
Per
Case
Control
Fans
208 Volts
Amps Watts
4' 1 0.06 14.0
6' 1 0.06 14.0
8' 2 0.12 28.0
LIGHTING DATA
Case
Length
Lights
Per
Row
Light
Length
Clearvoyant 4 LED Lighting
(Per Light Row)
Standard Power
(Cornice or Shelf)
120 Volts
Amps Watts
4' 1 4' 0.05 5.9
6' 2 3' 0.08 9.4
8' 2 4' 0.10 11.8
SELF-SERVICE DATA (CONTINUED)
Case
Length
(51") Total Amps
(208-3-60)
(54") Total Amps
(208-3-60)
L1 L2 L3 L1 L2 L3
4' 8.38 6.80 9.51 10.04 12.83 11.78
6' 13.90 10.01 12.38 14.75 18.86 17.34
8' 18.92 13.61 16.86 20.08 25.65 23.56
3

19 1/16" [48.5 cm]
21 13/16" [55.4 cm]
6 3/16" [15.8 cm]
18" [45.7 cm]
31 7/16" [79.8 cm]
35 1/8" [89.2 cm]
CASE HEIGHT
51" [129.5 cm]
INTERIOR HEIGHT
31 1/4" [79.4 cm]
VISUALDISPLAY
261/4"[66.7cm]
16"
12"
FLIP UP ACCESS FOR
CONTROLS/ELECTRICAL
BALLAST BOX WITH
HEAT CONTROLS
FRONT OF CASE
TOEKICK
4" X 4" MECHANICAL ACCESS
31 7/16" [79.9 cm]
96 1/2" [245.1 cm] 1" [2.5 cm]
35 1/8" [89.2 cm]
8" [20.3 cm]
6" [15.2 cm]
48 1/2" [123.2 cm] {4' case}
72 1/2" [184.2 cm] {6' case}
96 1/2" [245.1 cm] {8' case}
19 1/16" [48.5 cm]
VISUALDISPLAY
2811/16"[72.9cm]
6 3/16" [15.8 cm]
18" [45.7 cm]
31 7/16" [79.9 cm]
35 1/8" [89.2 cm]
CASE HEIGHT
54" [137.2 cm]
INTERIOR HEIGHT
34 1/4" [87.1 cm]
10"
16"
14"
FLIP UP ACCESS FOR
CONTROLS/ELECTRICAL
BALLAST BOX WITH
HEAT CONTROLS
21 13/16" [55.4 cm]
ENGINEERED FOR STORES WITH AMBIENT
CONDITIONS NOT TO EXCEED 75° AND 55%
RELATIVE HUMIDITY. DUE TO ENGINEERING
IMPROVEMENTS SPECIFICATIONS MAY CHANGE
WITHOUT NOTICE. ALL MEASUREMENTS ARE
TAKEN PER ASHRAE-72 SPECIFICATIONS.
NUMBERS ARE BASED ON STANDARD CASE SIZES.
CONSULT ENGINEERING.
PF-H
Self-Service Open Muti-Deck Merchandise
r
4', 6' & 8' (Deli)
PF-H
Rev. Date Rev. # Rev. Title
07-24-23 7 DATE UPDATE
03-15-22 6 DATE UPDATE
51" PROFILE
54" PROFILE (OPTIONAL)
TECHNICAL REFERENCE
4

Thank you for choosing Hillphoenix for your food merchandising needs. This handbook contains important technical infor-
mation and will assist you with the installation and operation of your new Hillphoenix specialty cases. By closely following
the instructions, you can expect peak performance; attractive fit and finish; and long case life.
We are always interested in your suggestions for improvements (e.g. case design, technical documents, etc.). Please feel
free to contact our Marketing Services group at the number listed below. Thank you for choosing Hillphoenix, and we wish
you the very best in outstanding food merchandising.
CASE DESCRIPTION
This manual specifically covers the PF-H deli application self-
service open multi-deck merchandiser.
STORE CONDITIONS
Hillphoenix cases are designed to operate in an air-condi-
tioned store that maintains a 75°F (24°C) store temperature
and 55% (max) relative humidity (ASHRAE conditions). Case
operation will be adversely affected by exposure to excessively
high ambient temperatures and/or humidity.
SHIPPING CASES
Transportation companies assume all liability from the time a
shipment is received by them until the time it is delivered to
the consumer. Our liability ceases at the time of shipment.
RECEIVING CASES
Examine fixtures carefully and in the event of shipping dam-
age and/or shortages, please contact the Service Parts
Department at the number listed below.
CASE DAMAGE
Claims for obvious damage must be 1) noted on either the
freight bill or the express receipt and 2) signed by the carrier's
agent; otherwise, the carrier may refuse the claim. If damage
becomes apparent after the equipment is unpacked, retain all
packing materials and submit a written request to the carrier
for inspection within 14 days of receipt of the equipment.
Failure to follow this procedure will result in refusal by the
carrier to honor any claims with a consequent loss to the
consumer.
If a UPS shipment has been damaged, retain the damaged
material, the carton and notify us at once. We will file a claim.
LOST/MISSING ITEMS
Equipment has been carefully inspected to insure the highest
level of quality. Any claim for lost/missing items must be
made to Hillphoenix within 48 hours of receipt of the equip-
ment. When making a claim please use the number listed
below.
SERVICE PARTS & TECHNICAL SUPPORT
For service parts questions regarding our cases, please
contact our Service Parts Department at 1-844-HPX-PART
For technical questions regarding our cases, please contact
our Technical Support Department at 1-833-280-5714.
CONTACTING THE FACTORY
If you need to contact Hillphoenix regarding a specific fixture,
be certain that you have both the case model number and
serial number. (This information can be found on the data tag,
located at the top-left interior, rear exterior panel or interior
rear lower storage of the case. Location may vary based on
case design.)
Hillphoenix Specialty Products
703 Franklin Street, PO Box 478
Keosauqua, IA 52565
Website: www.hillphoenix.com
GENERAL INFORMATION
5

Fig. 1 Horizontal supports
SUPPORTS
FLOOR PREP
1. Ask the general contractor if your current copy of the build-
ing dimensions are the most recently issued. Also, ask for
the points of reference from which you should take dimen-
sions to locate the cases.
2. Using chalk lines or a laser transit, mark the floor where
the cases are to be located for the entire lineup. The lines
should coincide with the outside edges of the case feet.
3. Move case as close as possible to its permanent location.
Remove all crating and shipping braces above the ship-
ping pallet. Loosen the plastic dust cover from the pallet,
but leave cover over the case to protect it while removing
the case from the pallet.
4. Shipping braces with a sled runner construction can either
have metal brackets that can be removed with a screw
gun, or wood blocks that can be removed with a J-bar.
Note: Shipping braces are normally located at each
corner of the case. (Shipping braces used vary and are
based on case design for best transport.)
5. Carefully, if horizontal supports, lift case up and off the
pallet. Remove dust cover. Installation hardware ships in a
marked packet located inside the case.
6. Leveling is necessary to ensure proper operation. Locate
the highest point on the positioning lines as a reference
for determining the proper height of the shim-pack level-
ers. A laser transit is recommended for precision and
requires just one person. Level adjustable feet by twisting,
if applicable, or shim as necessary under horizontal sup-
ports as this will help ensure that the case is not settling
over time.
7. Locate horizontal support positions along the chalk line
(Fig. 1). Spot properly leveled shim packs at each support
location.
8. If necessary, drill a hole in each end of every horizontal
support (Fig. 2) and fasten to the floor with concrete
anchors. Note: The holes do not need to be in the exact
locations specified here. Be sure that the anchors are
close to the end of the horizontal supports and at each
corner of the case.
LOCATION
This hot display case has been designed for displaying and
storing perishable food product. It is engineered for air-con-
ditioned stores with a maximum ambient of 75°F and 55%
relative humidity.
When selecting the location for placement of this case, avoid
the following conditions:
Excessive Air Movement
1. Doors
2. Air-conditioned vents
3. Other air sources C A U T I O N
Locate the horizontal supports under unit before
removing from pallet. Failure to do so will dam-
age the finished metal if correct lift points are
not identified prior to removal.
▲
2. Once the case is properly placed on the shim packs, check
the horizontal level of the case by placing a bubble level
on the front sill. Add/remove shim packs as needed.
LINE-UP & INSTALLATION
Single Case
1. Move the case into position. Using a “J” bar, raise the end
of the case (under cross support), and lower the horizontal
support on to the shim packs. Repeat on the other end of
the case.
C A U T I O N
These cases are not designed for excessive
external weight. Do not walk on top or inside
of cases. Doing so may result in case damage
and/or personal injury.
▲
W A R N I N G
Be certain that your hands and feet are out of
the way before lowering the case. Failure to do
so may result in serious injury.
▲
Fig. 2 Seismic anchoring locations
CASE INSTALLATION
6
Autres manuels pour Hillphoenix PF-H
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Dover marchandiseur
Manuels marchandiseur populaires d'autres marques

True
True GDIM-26 Manuel utilisateur

Structural Concepts
Structural Concepts Oasis Mobile Series Instructions d'installation

Hussmann
Hussmann Q2-SS Instructions d'utilisation d'origine

Haussmann
Haussmann RL Manuel utilisateur

Howard McCray
Howard McCray R-CDS32E-4 Manuel utilisateur

Hussmann
Hussmann microSC SHM-A Series Manuel utilisateur