ED900 108125350 www.dormakaba.com 02-2020
Quick Start Guide
ED900
• The ED operator must be completely installed
per the applicable dormakaba USA Inc. ED
Installation Instruction Manual.
• Door must be closed.
• Both program switches in the CLOSE “” position.
Step Directions Expected results
Power switch to ON position.
• A series of numbers and letters will show
up on the display.
• This will stop after two horizontal dashes
side by side move up and down several
times.
While the dashes are moving up and down,
press the bottom button on the display.
• This will identify which way the unit is
mounted.
• Letters and numbers will now display
right side up.
The display will show a “P“ on the right with
a rotating segment on the left.
When the braking circuit plug is in the
correct position the door will easily Press
open and close slowly. If the door is very
hard to Press open change the jumper
position.
28
A
B
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s LEARN
Fact-Setup
> 3s
> 8s
Press and hold the right button until Parameter
ID is displayed (approximately seconds), then
release the button.
Parameter ID will appear (ex. AS).
Press the right button. Displays the current setting.
Press the right button again. Display will flash the current setting.
Press the up and down buttons to change the
setting.
Press the right button to accept the changes. Displays the new parameter
setting.
Press the left button to return to the
programming menu.
Displays the current Parameter ID
(Step ).
Press the down button to go to the next
parameter setting (or) Go back to Step .
Press the left button to exit programming menu. Display will show a rotating
segment and a “”.
NOTICE
This guide is intended to be used as a reference to assist in
programming the dormakaba ED operator in accordance with
ANSI A. Standard for Low Energy Power Operated Doors.
Braking circuit plug position
A – Pull arm B – Press arm
Power fail closing speed.
• The door must be adjusted to close in
no less than three seconds but a
minimum of five seconds is recommended.
WARNING
If braking circuit plug is inserted
incorrectly, brake circuit will not
work. The door can close at high
speed!
WARNING
Verify power fail closing speed
and braking circuit plug position
before programming the door
and completing a learn cycle.
All three required
parameter settings
(AS, rd, Tb) must
be made to flash
even if the value
does not need to
be changed before
the door will move
to the learn cycle.