Olide 120B Manuel utilisateur

AUTOMATIC DOOR SPECIALISTS
INSTALLER NOTES:
The programming of the Open&Close stopping points will occur after the initial
hardware installation. An uninstalled unit will result in constant motor rotation.
For support, please email us: [email protected]
INSTALLATION MANUAL
Automatic swing door opener Olide-120B
Olide

Contents
1.
Technical Parameters..........................................................................................................................1
2.
Components...................................................................................................................................2
3.
Installations.................................................................................................................................... 3
3.1
Installation example......................................................................................................................... 3
3.2
Installation of base plate...................................................................................................................4
3.3
Installation of pull arm..................................................................................................................... 5
3.4
Installation of push arm.................................................................................................................... 6
3.5 Installation of Push arm for frameless glass door............................................................................. 8
3.7
Installation of operation system................................................................................................... ......9
3.9
Connection the operation system with the pull arm......................................................................... 10
3.10
Connection the operation system with the push arm....................................................................... 11
4.
Electrical Connections........................................................................................................................12
Control panel details...........................................................................................................................12
4.1
Connections with a keypad .........................................................................................................12
4.2
Connections with a microwave sensor ............................................................................................. 13
4.3
Connections with PIR sensors ....................................................................................................
13
4.4
Connections for a safety motion top scan .........................................................................................13
4.5
Connections for push buttons.............................................................................................................. 14
4.8
Connections for magnetic locks ............................................................................................................15
4.9
Connections for electric locks.........................................................................................................15
4.10
Connection with the touchless hand sensor switches ........................................................................... 15
4.15
Double door synchronous settings..................................................................................................18
4.16 Wireless push buttons settings........................................................................................................19
4.17 Remote control settings..............................................................................................................20
5.
Parameters Adjustment...........................................................................................................................21
5.1
hand programmer instruction.....................................................................................................................21
5.2
adjustment steps........................................................................................................................................22
6.
Trouble Shooting.....................................................................................................................................23
4.6
Connections for wiring disabled push buttons....................................................................................14
4.7
Connections for wireless handicapped push buttons .............................................................................14
3.6 Installation of Pull arm for frameless glass door.............................................................................. 8
3.8
Installation of cover...................................................................................................................... ......9
4.11
Connecting to wireless touchless sensor switch Olide-508,Olide-512 .................................................16
4.12
Connecting to wired touchless sensor switch Olide-514,Olide-513 and Olide-513.............................. 16
4.13
Connecting to wired touchless sensor switch Olide-514,Olide-513 and Olide-513N........................... 16
4.14
Connecting to wired narrow handicap push button 515......................................................................... 17
Olide

1 Technical Parameters
1
Voltage: 110-220 VAC +/-10%
Power Consumption: 50W
Opening Time: 3-7 sec. @ 90 degrees
Hold Open Time: 1-30 sec. Adjustable
Max. Door Frame Depth:
Door Width:
Max. 1200mm / 47.2"
Max. Opening Angle:
450mm / 17.7"
Min. 660mm / 26"
120 degrees
Environment Temperature: -20C to 50C -4F to 122F
Protection Class: IP12D
Product Weight:
9Kg 19.8lbs
Dimensions: L540 x H100 x W80mm
L21.2" x W3.9" x H3.14"
Olide

2 Component
Pull Arm(Option for inswing opening) Push Arm(Option for outswing opening)
2
Sensor cable hole
Motor Assembly:
Cover Plate:
Base Plate:
Power cable hole
Pull Arm(Option for frameless glass inswing opening)
Push arm glass clamp
Olide

3
Installation
3.1 Installation example
Pull Arm
The door opens to the inside toward the unit using the pull arm assembly.
Push Arm
The door opens to the outside away from the unit using the push arm assembly.
3
Olide

3
Installation
3.2 Installation of base plate
0.88"(22.5mm)
5.90"(150mm)
5.90"(150mm) 6.49"(165mm)
1.2"(30.5mm)
hole
2.0"(52mm)
1.18"(30mm)
Right side hinge
0.88"(22.5mm)
6.49"(165mm)
1.2"(30.5mm)
2.0"(52mm)
Left side hinge
4
18.2"(464.5mm)
As the picture shows, the base plate should
be mounted to the frame with eight wood
screws or eight M6-15 countersunk screws.
Please note that 20mm sensor cable hole is
always to the right side and that the power
cable access is always to the left. The sensor
cable access hole is very near the edge of the
plate.
0.59"(15mm)
1.5"(38.5mm)
18.2"(464.5mm)
0.59"(15mm)
1.5"(38.5mm)
As the picture shows, the base plate should
be mounted to the frame with eight wood
screws or eight M6-15 countersunk screws.
1.18"(30mm)
5.90"(150mm) 5.90"(150mm)
Olide

3
Installation
3.3 Installation of Pull arm
5
Adjust the opening angle by
moving the stopper
(The stopper is at the left side
when left hand installation).
At door right
240(9.44")
(
240(9.44")
20
160(6.3")
Fix the slide rail of pull arm on the
door panel as shown using three
round head wood
Screws
(if the door panel is steel, please
use M6*15 cross recessed head
screws.)
Attach the slide rail of the pull
arm on the door panel as shown
using 3 screws
0.78"
29(1.44")
Olide

3
Installation
12.40"(315mm)
3.4 Installation of Push arm
Loosen this 3 bolts and adjust the push arm length
according to the door depth(L) until the angle between
the push arm and the door panel is 90° . At door right
6
50(1.96") 290(11.42")
Fix the support holder of push arm on the door panel as shown
using two round head wood screws
(if the door panel is steel, please use M6*15 cross
recessed head screws.)
35(1.29")
Olide

3
Installation
7
3.4 Installation of Push arm
Stop screw
Adjust the stop screw position slotted
hole to allow full opening of the door. Do
not exceed 90°.
Olide

3
Installation
3.5 Installation of Push arm for frameless glass door
8
Clasp the door with door clamp tightly,then
fix the clamp with M5*8 Hexagon socket set
screws.
M5*8 Set screws
M5*8 Set screws
Please connect the push arm to the door
clamp with the M5*8 Hexagon socket
set screws.
Then connect the push arm to the motor.
Olide
Autres manuels pour 120B
1
Table des matières
Autres manuels Olide Système d'ouverture de porte