Delta-T Devices GP1 GSM Manuel utilisateur

User Manual for the
GP1/DL6 GSM
Modem System
GSM-UM-1.1
Delta
-
T Devices

Notices
Copyright
Copyright © Delta-T Devices 2006
All parts of the GSM System design and documentation are the exclusive copyright of
Delta-T Devices Ltd.
CE Conformity
Meets the intent of the EMC Directive 89/336/EEC.
See GSM-BX1 & GP1-DL6 Network Regulatory Information. PDF
in the Product Documentation folder of the Delta-T Software and Manuals CD.
Design Changes
Delta-T Devices Ltd reserves the right to change the designs and specifications of its
products at any time without prior notice.
User Manual Version: GSM-UM-1.1 Dec 4 2006
Delta-T Devices Ltd Tel: +44 1638 742922
130 Low Road, Burwell Fax: +44 1638 743155
© 2006 Delta-T Devices Ltd Page 2
Cambridge CB25 0EJ email: [email protected]
UK web: www.delta-t.co.uk

© 2006 Delta-T Devices Ltd Page 3
Contents
Layout........................................................................................ 4
External connectors and cable glands.......................................................................5
Introduction............................................................................... 6
Antenna..................................................................................................................... 6
Logger cabling........................................................................................................... 6
Software....................................................................................................................6
Unpacking ................................................................................. 7
Basic GSM Modem Box ............................................................................................ 7
GSM Modem Box (solar power) type GSM-BX1/SP.................................................. 7
GSM Modem Box (internal battery) type GSM-BX1/IB.............................................7
GSM Modem Box (without battery) type GSM-BX1/EB............................................ 7
Accessories...............................................................................................................8
Also required for all systems .....................................................................................9
Getting started........................................................................ 10
Set up at your bench first!........................................................................................ 10
Fit a SIM card..........................................................................................................10
Install the antenna................................................................................................... 11
Supply power to the modem....................................................................................12
Use of the Timer...................................................................................................... 12
Configure, Test or Add Text Message to modem.................................................... 13
Create a modem connection in DeltaLINK .............................................................. 16
Install Modem Box................................................................................................... 17
Install Solar Panel (option) ...................................................................................... 18
Install logger(s)........................................................................................................ 19
Battery life Considerations.......................................................................................20
Wiring Diagrams..................................................................... 21
Wiring scheme for GSM-BX1/SP… Solar Power..................................................... 21
Wiring scheme for Solar Power and Timer..............................................................21
Wiring scheme for GSM-BX1EB… External Battery................................................ 22
Wiring scheme for GSM-BX1/ IB…Internal Battery ................................................. 22
Other Documents.................................................................... 23
Specifications ......................................................................... 24
Environmental specifications................................................................................... 26
Electromagnetic Compatibility (EMC)...................................................................... 26
Care and Safety....................................................................... 27
Technical Support .................................................................. 27
Terms and Conditions of sale..................................................................................27
Service and Spares.................................................................................................28
Technical Support.................................................................................................... 28

Layout
Extension
cable from GP1
to modem
GP1 mounting
bracket
Solar panel
Solar panel
bracket
Modem
Antenna
connector
Modem
power cable
RS232 to
logger +
control line for
text
messaging
Battery
Brown +’ve
Cable
harness
Fuse and
connectors
on DIN rail
Timer
Solar regulator
/charger
© 2006 Delta-T Devices Ltd Page 4

External connectors and cable glands
Cable glands for
1) external antenna,
2) external battery or
solar panel
and/or
3) control line from
logger for triggering
text messages
Breather
M8 socket
for connecting to
logger(s) via
GP1 Network Cablin
g
© 2006 Delta-T Devices Ltd Page 5

© 2006 Delta-T Devices Ltd Page 6
Introduction
The GSM Modem System provides battery powered GSM modem communications for
GP1 and DL6 loggers. Three power options are available:
Solar powered internal rechargeable lead-acid battery (GSM-BX1/SP)
Internal lead-acid battery with timer (GSM-BX1/IB)
Timer and cabling for an external lead-acid battery (GSM-BX1/EB).
The weatherproof box has an external connector for plugging in GP1 or DL6 loggers
via the GP1 network cabling system. At least one network cable is required.
Cable glands are provided for:
cable to external battery (GSM-BX1/EB)
optional signal cable for triggering transmission of SMS text messages
optional external antenna cable.
Inside are mounting points for the modem, battery, and solar regulator option.
A DIN rail with terminal connectors and a fuse holder is provided. It also takes the
optional timer.
Antenna
If mobile phone reception is good the modem can be fitted with a stub antenna.
If reception is poor then the external antenna option will provide better reception.
Logger cabling
A GP1 network extension cable is required to connect a logger to the modem box.
A single GP1 logger may be connected via a type GP1-EXT extension cable.
Each DL6 logger requires at least a type GP1/DL6-M8 cable.
Up to ten GP1 or DL6 loggers may be connected with suitable cabling.
These cables also distribute power from the Modem System battery to GP1 loggers.
See also: Install Loggers on page 19
Software
Once the Modem System is fully installed, each logger can be accessed, either from a
PC with a suitable telephone link, using the DeltaLINK-PC software, or a GSM-
enabled Pocket PC using Pocket DeltaLINK.
Modems supplied by us are pre-programmed - but you will have to purchase and
install your own data-enabled SIM card in the modem.
See also: Getting Started on page 10.
A modem configuration utility GSMConfig is installed on your PC with DeltaLINK.
It can be used to set up text messaging or to configure the modem or test the
modem.
The GSM modem can be configured to send a text message to a mobile phone, when
triggered by a logger control relay. It requires a 2-core cable from the logger to the
modem box DIN rail terminals.

Unpacking
Check your contents against your order and any packing lists.
All GSM Modem Box Systems include the Basic GSM Modem Box:
Basic GSM Modem Box
Siemens TC35i modem
Plastic Modem Box, sealed to IP66, fitted with:
GP1 network cable connector (5 pole M8 female),
3 cable glands for:
external battery or solar power cable,
optional signal cable for triggering transmission of SMS text messages,
and optional external antenna cable,
PTFE breather, DIN rail with terminals and 3A fuse holder, Desiccant bag.
PC-modem serial cable GSM-RS-DB9 to configure the modem from a PC.
GSM Modem Box (solar power) type GSM-BX1/SP
In addition to the Basic GSM Modem Box, this
includes:
30W solar panel
Solar Panel Mounting Bracket and U-bolts
Solar regulator/charger
10Ah sealed lead acid battery.
2 m power cable with flying leads
GSM Modem Box (internal
battery)
type GSM-BX1/IB
In addition to the Basic Modem Box, this includes:
10Ah sealed lead acid battery.
Timer
GSM Modem Box (without battery)
type GSM-BX1/EB
In addition to the Basic Box and Modem, this includes:
Timer
does not include
This a battery or external battery cable.
© 2006 Delta-T Devices Ltd Page 7

Accessories
The following optional extras may also have been supplied:
External antenna for TC35i
modem with 5m cable GSM-ANT-1
© 2006 Delta-T Devices Ltd Page 8
Internal stub antenna for
TC35i modem GSM-ANT-2
Spares Kit GSM-SK1
Mounting Kit for GSM
Modem Box
GSM-MK1
Spare rechargeable 10 Ah
lead acid battery LBAT4
Battery charger LBC4
Mains lead for battery
charger
LBC4-ML-UK
LBC4-ML-EU
LBC4-ML-US
Solar Panel power kit GSM-SOL4
GP1 comms and power
extension cable .
XX = 1m, 5m, 10m, or 25m GP1-EXT-XX
GP1 control line cable
GP1-CC-100
GSM external battery cable GP1-EPC-02
DL6 M12 cable to M8
connector GP1/DL6-M8
4-way GP1 network
expansion block GP1-EB/4

© 2006 Delta-T Devices Ltd Page 9
Also required for all systems
You will also need to provide:
Data enabled SIM card from a local mobile phone service provider
GP1/DL6 extension and/or network cable(s) for your logger(s)
GP1 and/or DL6 logger(s) running firmware v1.30 or later
PC with a telephone modem, running DeltaLINK-PC v2.2 or later
See also the Accessories on page 8.
To obtain the latest DeltaLINK version
Link to http://delta-t.co.uk/software-download.html.
To Upgrade DeltaLINK-PC firmware
To upgrade your firmware, from the PC Start menu select Programs, DeltaLINK-PC,
Firmware Upgrade, and follow the on-screen instructions.

Getting started
The Modem Box is shipped preassembled, apart from the battery, the antenna, and
any external cabling.
Set up at your bench first!
Use of the optional GSMConfig modem configuration software will require you to
temporarily connect the PC directly to GSM Box with a serial cable.
So, if possible, set up and test the system next at your desk PC before installing it in
the field.
Fit a SIM card
You must locally obtain and fit a data-enabled SIM card.
1. Obtain a
data-enabled
© 2006 Delta-T Devices Ltd Page 10
SIM card with a phone
number.
2. Remove the modem from the GSM box by undoing
two M3 x 35mm screws
3. Find the SIM card slot and press the adjacent button to
eject the card holder.
4. Fit the data enabled SIM card
5. Refit the modem in the box.
Locate SIM card
eject button
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Modem populaires d'autres marques

Davicom
Davicom DM562AP Manuel utilisateur

EpiValley
EpiValley TATA indicom SXC-1080 Manuel utilisateur

Zte
Zte WiMAX Manuel utilisateur

Intelimax
Intelimax MA-2060 Manuel utilisateur

SMC Networks
SMC Networks D3CM1604V Manuel d'utilisation et d'entretien

Telstra
Telstra Wi-Fi 4G Advanced Pro X Manuel utilisateur

US Robotics
US Robotics 3453C Manuel utilisateur

MaxTech
MaxTech Plug & Play Internal Voice/FAX/Data/SVD... Manuel utilisateur

Zte
Zte MF823 Manuel utilisateur

Four-Faith
Four-Faith F1403 Manuel utilisateur

Sierra Wireless
Sierra Wireless AIRLINK MP595W Manuel utilisateur

Gemtek
Gemtek WiMAX WIXFBR-103 Manuel utilisateur