Delta Energy Systems SOLIVIA Gateway M1 G2 Fiche technique

Operation and
installation manual
SOLIVIA Gateway M1 G2


1Operation and installation manual SOLIVIA Gateway M1 G2
ENGLISH
The manual is subject to change.
Please check our website at www.solar-inverter.com
for the most up-to-date manual version.
© Copyright – Delta Energy Systems (Germany) GmbH - All rights reserved.
This manual accompanies our equipment for use by the end users.
The technical instructions and illustrations contained in this manual are to be treated as condential and no part may be reprodu-
ced without the prior written permission of Delta Energy Systems Service engineers and end users may not divulge the information
contained herein or use this manual for purposes other than those strictly connected with correct use of the equipment.
All information and specications are subject to change without notice.

2 Operation and installation manual SOLIVIA Gateway M1 G2

3Operation and installation manual SOLIVIA Gateway M1 G2
ENGLISH
1 About this Manual 4
1.1 Purpose of this Manual 4
1.2 Warnings and Symbols 4
2 Intended Use 5
3 General Safety Instructions 5
4 Scope of Delivery 6
5 Planning 6
5.1 Items / Tools Required for Installation 6
5.2 Further Requirements 6
6 Connector Positions 7
7 Installation Procedure 8
7.1 Registration 8
7.2.1 Mounting on a DIN Rail 8
7.2.2 Mounting Directly to the Wall 9
7.3 RS485 Connection 9
7.4 Ethernet Connection 9
7.5 Connection of the Ripple Control Receivers 9
7.6 Power Connection 11
8 LED Status 12
9 Troubleshooting RS485 / Ethernet Communication 12
10 Configuration through Web Server 12
10.1 Access the Configuration Web Server 13
10.2 First Log in 14
10.3 Network Settings 14
10.4 Connection Settings 15
10.4.1 RS485 Bus Communication 16
10.4.1.1 Wireless RS485 Modem 16
10.4.2 Delta Database Connection 16
10.4.3 Force RS485 Bus Scan 16
10.4.3.1 List of Connected SOLIVIA Solar Inverters 16
10.4.4 Force Gateway Reset 17
10.4.5 Restart Gateway 17
10.5 Digital Inputs 17
10.5.1 Power Management 18
10.5.2 Power Factor Control 18
10.6 Power Balancing 19
10.6.1 Configuration 19
10.6.1.1 Feature Activation 20
10.6.1.2 Power Balancing Requested from the Public Grid Supplier 20
10.6.1.3 Grid Assignment 20
10.6.2 Balancing 20
10.7 Inverter Information 21
11 Delta Service Software 22
12 Reset Button 22
13 Product Specification 23
14 Certificates 49

4 Operation and installation manual SOLIVIA Gateway M1 G2
Congratulations on the purchase of the SOLIVIA Gateway M1 G2.
These directions will help you become familiar with this product. Please observe the
safety regulations of the individual countries. Careful handling of your product will con-
tribute to its service life durability and reliability.
This manual is part of the product and is only valid for the SOLIVIA Gateway M1 G2.
Keep this manual in a safe place.
Read this manual carefully and follow the instructions given in this manual. This man-
ual contains important information for installing and operating the gateway.
Observe and follow the information for safe use (please refer to Chapter 3).
Both the installer and the operator must have access to this manual and must be famil-
iar with the safety instructions.
Here, you will nd explanations for the warnings and symbols used in this
manual:
Indicates a hazardous situation, that could result in pro-
perty damage.
Indicates a hazardous situation. If not prevented, an acci-
dent result in moderate or minor injury to humans.
Indicates a hazardous situation. If not prevented, an
accident result in death or serious injury to humans.
Indicates a hazardous situation. If not prevented, an acci-
dent result in death or serious injury to humans.
This symbol warns of the dangers of electric shock
due to high electrical voltage.
This symbol warns against a general danger.

5Operation and installation manual SOLIVIA Gateway M1 G2
ENGLISH
The SOLIVIA gateway is the interface between your SOLIVIA inverter and the SOLIVIA
Monitor web portal. It transmits all relevant data from your SOLIVIA inverter (for exam-
ple the supplied AC energy of the day, the actual AC power, some error bytes etc.) to
the SOLIVIA Monitor web portal. It allows you continuous monitoring of your PV system
from anywhere that you have internet access.
The SOLIVIA gateway must be used indoors with IP20 environmental conditions.
The SOLIVIA gateway must only be operated according to its intended use.
Please observe the safety regulations of the individual countries. Careful handling of
your product will contribute to its service life durability and reliability. These are essen-
tial pre-requisites for maximum yield from your product.
• Inappropriate handling can lead to physical injury and material damage!
• Do not remove warning labels that have been attached to the SOLIVIA gateway
by the manufacturer.
• Observe all points in this installation and operation manual!
• Repair work on the device may be carried out by the manufacturer only.
• For a safe and normal operation of the SOLIVIA gateway, it is absolutely
necessary that the gateway is installed and operated according to this manual
(see IEC 62109-5.3.3).
• Delta Energy Systems is not responsible for damage caused by failure to observe
the operation and installation instructions in this manual.
In order to avoid damage to property or personal injury,
only qualied, trained electricians may work on the equip-
ment. The qualied electrician must familiarise himself/
herself with this manual.
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information regarding
the collection systems available. If electrical appliances
are disposed of in landlls or dumps, hazardous sub-
stances can leak into the groundwater and get into the
food chain, damaging your health and well-being. When
replacing old appliances with new once, the retailer is
legally obligated to take back your old appliance for dis-
posal at least for free of charge.

6 Operation and installation manual SOLIVIA Gateway M1 G2
• SOLIVIA Gateway M1 G2
• AC power plug (3 adapters for usage in different countries)
• Operation and installation manual
• Label
Following items and tools are required for installation but are not included to the
SOLIVIA gateway box. Please make sure to have them available before starting instal-
lation.
• 1 standard twisted pair Ethernet cable
•
The Ethernet cable should meet or exceed the standard CAT5 and should not exceed
a length of 100 m. These standard twisted pair Ethernet cable can be purchased for
your installation at many electronics and ofce supply retailers. The gateway requires
a shielded cable STP, FTP, S/FTP or S/STP.
1 RS485 communication interface cable
•
The RS485 cable should meet the protection class IP65. We recommend using the
RS485 cable from Harting (Part Number: 09 45 145 1560). Cable lengths should not
exceed 1200 m if Baud rate is 19200 (default value). The required cable quality is the
same as for the Ethernet connection: at least shielded (STP, FTP, S/FTP or S/STP)
CAT5 cable or better.
2 screws are required to mount the gateway directly to the wall:
»Nominal diameter: 4 mm
»Maximum head diameter: 9 mm
»Maximum height of head: 3 mm
• Screwdriver (if gateway should be mounted to the wall); size of the screwdriver
depends on used screws
The SOLIVIA gateway must be installed only indoors according to protection class
IP20.
If more than one SOLIVIA solar inverter will be connected in a chain, ensure that
each inverter has a unique ID assigned in the solar inverter user interface.

7Operation and installation manual SOLIVIA Gateway M1 G2
ENGLISH
• Please check the SOLIVIA solar inverter manual for instructions on how to select
the inverter ID.
• The gateway must have an AC power outlet within 2 meters of the gateway.
Please make sure, that DHCP is activated at your router, so that the IP address of
your gateway is automatically found. If DHCP is disabled at your router the gateway
uses the default IP conguration. For further information, please refer to Chapter 10.3
GW
STATUS
RESET RS485
EXT. CONTROL
1 2 3 4 5 6 7 8 A B LAN INPUT
5V
RESET For detailed information, please refer to Chapter 7.8
RS485 Connection of your SOLIVIA inverter with the
SOLIVIA gateway.
EXT. CONTROL Ripple control receivers control the power management (power
limitation) and the power factor (cos ϕ).
LAN Connection of your SOLIVIA gateway with an internet connected
network point.
INPUT 5V Gateway power supply connector.
Status LED

8 Operation and installation manual SOLIVIA Gateway M1 G2
First register for a SOLIVIA Monitor user account on the web at: http://register.solivia-
monitor.com. After registering you will receive, via email, a user name, a password,
and a link to a Conguration Wizard that will allow you to set up and monitor your site
from the SOLIVIA Monitor web portal. Complete the Conguration Wizard setup before
installing the monitoring hardware. In this way, you can go to the web portal after the
hardware installation and verify everything is working correctly.
At the install site, verify the internet connection is active by connecting a laptop to the
internet connected network point and pointing a web browser to www.solar-inverter.
com.
Mount the SOLIVIA gateway with the appropriate AC power location specied in Chap-
ter 5.2. You have either the possibility to mount the SOLIVIA gateway on a DIN rail or
directly to the wall.
The gateway can be mounted on the following DIN Rails:
• DIN Rail according to EN60715 TH35-15
• DIN Rail according to EN60715 TH35-7.5
The gateway should be installed horizontally with connectors on the bottom.
To mount, snap the gateway on the DIN rail as shown in Figure 1:
1. Pull the gateway's DIN rail latch OUT.
2. Tilt the unit slightly upwards, hook the top end onto the DIN rail and push down-
wards until stopped.
3. Position the bottom front end against the DIN rail until it has snapped onto the DIN
rail.
4. Push the gateway's DIN rail latch IN to lock.
2
1
2
3
4
Figure 1: Mounting the gateway on a DIN rail
Autres manuels pour SOLIVIA Gateway M1 G2
1
Table des matières
Langues :
Autres manuels Delta Energy Systems Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur