Deif AGC 150 Manuel utilisateur

AGC 150 Engine drive
Operator's manual
4189341305C

1. Introduction
1.1 Symbols for hazard statements......................................................................................................................................................................................... 3
1.2 About the operator's manual...............................................................................................................................................................................................3
1.3 Warnings and safety.................................................................................................................................................................................................................4
1.4 Legal information....................................................................................................................................................................................................................... 4
2. About the AGC 150 Engine drive
2.1 Display, buttons and LEDs.....................................................................................................................................................................................................5
2.2 Display settings..........................................................................................................................................................................................................................6
2.3 Mimic function.............................................................................................................................................................................................................................6
2.4 Running modes........................................................................................................................................................................................................................... 7
3. Menus
3.1 Menu structure.............................................................................................................................................................................................................................8
3.2 Parameters menu...................................................................................................................................................................................................................... 8
3.2.1 Menu numbers.................................................................................................................................................................................................................... 9
3.2.2 The jump to parameter function...............................................................................................................................................................................9
3.3 View menu...................................................................................................................................................................................................................................10
3.3.1 Display views.....................................................................................................................................................................................................................10
3.3.2 Display text........................................................................................................................................................................................................................ 10
3.4 Status text....................................................................................................................................................................................................................................11
3.5 Service view...............................................................................................................................................................................................................................12
3.6 Engine shortcuts..................................................................................................................................................................................................................... 13
3.6.1 PID configuration............................................................................................................................................................................................................. 13
3.6.2 ECU Diagnose and Force Regeneration.............................................................................................................................................................13
3.7 General shortcuts................................................................................................................................................................................................................... 14
3.8 Exhaust after-treatment (Tier 4/Stage V)...............................................................................................................................................................14
4. Alarm handling and log list
4.1 Alarm handling...........................................................................................................................................................................................................................18
4.2 Logs menu...................................................................................................................................................................................................................................19
Operator's manual 4189341305C EN Page 2 of 19

1. Introduction
1.1 Symbols for hazard statements
DANGER!
This shows dangerous situations.
If the guidelines are not followed, these situations will result in death, serious personal injury, and equipment
damage or destruction.
WARNING
This shows potentially dangerous situations.
If the guidelines are not followed, these situations could result in death, serious personal injury, and equipment
damage or destruction.
CAUTION
This shows low level risk situation.
If the guidelines are not followed, these situations could result in minor or moderate injury.
NOTICE
This shows an important notice
Make sure to read this information.
1.2 About the operator's manual
This document gives the necessary information to operate the controller.
CAUTION
Installation errors
Read this document before working with the controller. Failure to do this may result in human injury or damage
to the equipment.
Intended users of the operator's manual
The operator's manual is for the operator that uses the controller regularly.
The manual describes the LEDs, buttons and screens on the controller, alarm handling, and the logs menu.
Operator's manual 4189341305C EN Page 3 of 19

1.3 Warnings and safety
Factory settings
The controller is delivered pre-programmed from the factory with a set of default settings. These settings are based on
typical values and may not be correct for your system. You must therefore check all parameters before using the controller.
Data security
To minimise the risk of data security breaches:
• As far as possible, avoid exposing controllers and controller networks to public networks and the Internet.
• Use additional security layers like a VPN for remote access, and install firewall mechanisms.
• Restrict access to authorised persons.
1.4 Legal information
Legal information
Third party equipment
DEIF takes no responsibility for the installation or operation of any third party equipment, including the engine. Contact the
engine company if you have any doubt about how to install or operate the engine.
Warranty
NOTICE
Warranty
The controller is not to be opened by unauthorised personnel. If opened anyway, the warranty will be lost.
Disclaimer
DEIF A/S reserves the right to change any of the contents of this document without prior notice.
The English version of this document always contains the most recent and up-to-date information about the product. DEIF
does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the
English document. If there is a discrepancy, the English version prevails.
Copyright
© Copyright DEIF A/S. All rights reserved.
Software version
This document is based on the AGC 150 software version 1.16.
Operator's manual 4189341305C EN Page 4 of 19

2. About the AGC 150 Engine drive
2.1 Display, buttons and LEDs
No. Name Function
1 Power Green: The controller power is ON.
The controller power is OFF.
2 Display screen
Resolution: 240 x 128 px.
Viewing area: 88.50 x 51.40 mm.
Six lines, each with 25 characters.
3 Navigation Move the selector up, down, left and right on the screen.
4 OK Go to the menu system.
Confirm the selection on the screen.
5 Back Go to the previous page.
6 AUTO mode The controller automatically starts and stops the engine.
No operator actions are needed.
7 Silence horn Stops an alarm horn (if configured) and enters the alarm menu.
8 Shortcut menu Access jump to parameter, running mode, test and lamp test.
9
mode
The controller cannot automatically start and stop the engine.
The operator can start and stop the engine manually from the display.
10 Engine
Green: There is running feedback or an external signal.
Green flashing: The engine is getting ready.
Red: The engine is not running, or there is no running feedback.
11 Stop Stops the engine if or manual mode is selected.
12 Start Starts the engine if or manual is selected.
Operator's manual 4189341305C EN Page 5 of 19

2.2 Display settings
To adjust for ambient lighting, configure the display settings.
Parameters > Basic settings > Controller settings > Display > Display control
Parameter Text Range Default
9151 Backlight dimmer 0 to 15 * 12
9152 Green LEDs dimmer 1 to 15 * 15
9153 Red LEDs dimmer 1 to 15 * 15
9154 Contrast level to 0
9155 Sleep mode timer 1 to 1800 s 60 s
9156 Enable mode timer) OFF
ON ON
9157 Alarm Jump OFF
ON ON
9158 Engineering units Bar/Celsius
PSI/Fahrenheit Bar/Celsius
NOTE * Low numbers are minimum brightness and high numbers are maximum brightness.
2.3 Mimic function
With the mimic function you can select how the control buttons and LEDs are shown on the controller's display.
Parameters > Basic settings > Controller settings > Display > LED mimic
Parameter no. Item Range
6082 LED mimic
Standard with genset
Standard
Guided with genset
Guided
Standard
The control buttons and LEDs are shown.
If you stop the engine, the engine symbol is not shown.
Standard with genset
The control buttons and LEDs are shown.
If you the stop the engine, the engine symbol is shown in red.
Operator's manual 4189341305C EN Page 6 of 19

Guided
Active control buttons and LEDs are shown, inactive are not shown.
Example: The AGC 150 Engine drive is in mode, and the
engine is not operating. Only the start button is shown, as this is
the only possible action.
Guided with genset
Active control buttons, LEDs and the engine symbol are shown,
inactive are not shown.
Example: AGC 150 is in mode. The engine is not
operating. The only possible action is to start the engine, and so
only the start button and the red engine symbol are shown.
2.4 Running modes
The controller has three different running modes, a block mode and a test mode. Push the Shortcut button and select
Running Modes to see the running modes and block mode. To select the test mode, push the Shortcut button and
select Start Test.
Mode Description
AUTO The controller automatically starts and stops the engine.
The controller cannot automatically start and stop the engine. The operator can start these sequences using
the buttons on the controller, Modbus commands or the digital inputs.
MANUAL The operator can use the digital increase/decrease inputs (if they are configured) and the Start and Stop
buttons. When the engine starts in manual mode, it will start without subsequent regulation.
BLOCK The controller cannot start a sequence, for example the start sequence. Select the block mode when you do
maintenance work on the engine.
Test The test sequence will start when you select the test mode.
NOTE The engine will shut down if you select the block mode while the engine is operating.
Operator's manual 4189341305C EN Page 7 of 19

3. Menus
3.1 Menu structure
The controller has two menu systems, which can be used without password entry:
•The View menu system: Shows the operating status and values. The system has 20 configurable windows, that can be
entered with the arrow buttons.
•The Parameters menu system: The operator can see the controller's parameters. A password is necessary to change
the parameter settings.
3.2 Parameters menu
You can configure the controller in the parameters menu and you can also find information, which is not available in the
view menu. From the view menu, push the button to find the parameters menu. Use the and buttons to find
the different parameters and select with the button.
Parameters menu example
This is an example of how to change the running detection type.
Operator's manual 4189341305C EN Page 8 of 19

3.2.1 Menu numbers
Each parameter has a menu number. You can find the number in the upper right corner on the display screen.
You can also find the menu number with the utility software:
1. Select Parameters from the vertical toolbar on the left.
2. Set the view mode to list. The view mode can be found in the left corner of the screen.
3. The menu numbers are in the Channel column.
3.2.2 The jump to parameter function
If you know the menu number for a parameter, you can use the jump to parameter function to go directly to the parameter.
On the controller:
1. From the view menu, push the Shortcut button to see the jump to parameter function:
2. Use the and buttons to go to Jump to parameter and push the button.
3. Use the and buttons to change the numbers, and push the button to save. Use the and buttons to
move to the next number.
Operator's manual 4189341305C EN Page 9 of 19

3.3 View menu
The view menu is shown when the controller is turned on, and you can see the operating status and values. The event and
alarms list will also be shown if an alarm is on.
1. Operating status
2. Values and information
3. Page number
The view menu has 20 different display views. Use the and buttons to select a view.
3.3.1 Display views
The controller has 20 different display views, and 5 of the views are pre-configured. You can configure the views with the
utility software.
Line View 1 View 2 View 3 View 4 View 5
1 0.0V Multi input 20 0.0 Aftertreatment EIC T. Coolant Serv1 0d 0h
2 MPU 0rpm Multi input 21 0.0 EIC Tier 4 Icons EIC T. Turbo Oil Serv2 0d 0h
3 - Multi input 22 0.0 - EIC T. Exh. Right -
4 [yyyy-mm-dd time] Multi input 23 0.0 - EIC T. Oil -
5 Run absolute 0 hrs - - EIC T. Fuel -
3.3.2 Display text
Configure the display views
You can configure the display views with the utility software:
1. Select the Configuration of the user views button in the toolbar.
2. In the pop-up window, select the display view to be changed.
Operator's manual 4189341305C EN Page 10 of 19
Autres manuels pour AGC 150
9
Table des matières
Autres manuels Deif Entraînement CC
Manuels Entraînement CC populaires d'autres marques

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manuel utilisateur

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manuel de la liste des pièces

Chamberlain Garog
Chamberlain Garog D Series Manuel utilisateur

Parker
Parker PDS Series Manuel utilisateur

Festo
Festo DGC G Series Guide de configuration

Binks
Binks QS-5012-1-CE Manuel utilisateur