Before You Start .........................................................................................................................4
The Engine Information Center (EIC) .................................................................................5
Brightness/Contrast Adjustment ........................................................................................6
Navigation Using Soft Keys ...................................................................................................6
EIC DP2xx Force and Inhibit Regeneration software function description .........8
Main Menu .................................................................................................................................10
Setup Options ..........................................................................................................................27
J1939 Monitor Controls .........................................................................................................31
LED Indicators ...........................................................................................................................35
Installation/Mounting Instructions ................................................................................. 36
Connection/Pinout settings ...............................................................................................42
DP2xx Series Accessories .................................................................................................... 44
Important Safety Information ............................................................................................47

3
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx

4
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
Before You Start
Thank you for purchasing the Danfoss DP2xx Series Graphical Terminal.
This package contains the following items:
yOne (1) DP2xx Series Graphical Terminal
yOne (1) Panel Seal Gasket
yOne (1) Mounting Bracket
yFour (4) Bracket Mounting Screws
yOne (1) DP2xx Series Graphical Terminals User Manual
Please ensure all parts are included prior to use.

5
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
The Engine Information Center (EIC)
The DP2xx Series Graphical Terminal comes installed with the powerful and
exible Danfoss Engine Information Center (EIC) J1939 engine monitor
software application. Use the application to customize the look and feel of
your individual engine monitoring needs by creating and controlling analog
and digital display information in the screen congurations that work best for
your performance requirements.
Navigate through diagnostic information and conguration screens with ease
by using the four context-dependent soft keys located at the front of the
display. Choose from 50 dierent monitoring parameter proles to customize
the DP2xx terminal.
Up to four signals can be monitored on each screen. Use the Engine
Information Center software to congure the DP2xx for alarms and alerts.

6
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
Brightness/Contrast Adjustment
Adjust brightness and contrast levels by
pressing soft key 2. This will display the
brightness and contrast soft key bar.
The bar will disappear after 3 seconds of
inactivity.
Navigation Using Soft Keys
The DP2xx Series Graphical Terminal is controlled by navigation through a set
of four soft keys located at the lower front of the display. The keys are context
dependent. Soft key selection options are displayed above each key and are
dependent on the current navigation location within the engine monitor
software program. As a general rule, the far right soft key is the selector
button and the far left soft key is the step back one screen key. To optimize full
screen use, the on-screen selections are not displayed when not in use. Press
any soft key to display current selection options. The selection options will be
displayed for three seconds.

7
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
Navigation Using Soft Keys
Screen Navigation
Brightness/Contrast Press to access brightness and contrast settings
Navigate Up Press up to move up through menu items or screens
Navigate Down Press up to move down through menu items or screens
Main Menu Press to go to Main Menu screen
Exit/Back one screen Press to go back one screen
Select Press to accept selection
Next Press to select next digit or screen element
Initiate Switch Press to force regeneration of particulate lter
Inhibit Switch Press to inhibit particulate lter regeneration
Previous Press to navigate to previous menu
Next Brightness/ Initiate Inhibit
Menu Contrast Switch Switch
Exit/Back Navigate Navigate Select
One Screen Up Down
Exit/Back Navigate Navigate Next
One Screen Up Down
Brightness/ Navigate Navigate Next
Contrast Up Down

8
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
EIC DP2xx Force and Inhibit Regeneration software function description
While the unit is displaying one of the Monitor Screens, pressing any soft key
will show the available Navigation actions in an action menu. There are two
separate action menus on this level; the rst one to appear contains the
following actions (from left to right):
yNext Menu
yScreen Brightness/Contrast
yInitiate Switch (Force Regeneration)
yInhibit Switch (Inhibit Regeneration)
Selecting ‘Next Menu’ will display the second action menu with actions
unrelated to the function described herein. Pressing it again will show the
rst set of actions once more. If no soft keys are pressed and released for
2.5 seconds while the action menu is shown the menu will disappear and the
actions are no longer available. Pressing (and releasing) any soft key will
activate the rst menu once more.

9
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
yForce Regeneration action
If the user selects the Force Regeneration action while the action menu is
being displayed; bit 2 (out of 0-7) in byte 5 (out of 0-7) will be set to 1 (true)
in the J1939 message PGN 57344 bound for the engine. This change
prompts the message to be transmitted. The bit will stay like this for the
duration of the soft key press or for the 2.5 second countdown to soft key
inactivity, whichever occurs rst. The bit is then reset to 0 (false).
The soft key press also prompts the display to show a popup lasting for
5 seconds. This popup simply says “Regeneration Forced”. If the display
does not receive an acknowledgement from the engine on the change to
message PGN 57344 the last half of the popup will say “No Engine Signal”.
This acknowledgement is the command that lights up the Forced
Regeneration LED on the display unit housing.
yInhibit Regeneration action
If the user instead selects the Inhibit Regeneration action while the action
menu is being displayed the same function as described above will be
executed, with some dierences;
–Bit 0 (out of 0-7) in byte 5 (out of 0-7) is set to 1 (true) instead.
–The popup says “Regeneration Inhibit” instead.
–The acknowledgement lights up the Regeneration Inhibit LED instead.

10
11032748_Rev DA_Sep2014
User Manual EIC-Engine Information Center – DP2xx
Main Menu
Start Menu
Start Menu – Main Menu
The Main Menu screen is the starting
point for conguring the DP2xx Series
Graphical Terminal.
Main Menu
Basic Setup Use to set Time/Date, Language and Units
Diagnostics Use to set System Info, access Fault Log and J1939 lists.
Screen Setup Use to set Parameters, choose number of screens and select
screen. (PIN protected)
System Setup Use to reset trip and default settings,
access CAN information,
select display settings and set PIN information.
(PIN protected)
Ce manuel convient aux modèles suivants
2
Table des matières
Manuels Terminal tactile populaires d'autres marques

Wincor Nixdorf
Wincor Nixdorf iPOS plus Advanced Manuel utilisateur

Ingenico
Ingenico AXIUM EX4000 Manuel utilisateur

Heisei Electronics
Heisei Electronics Q-POS 815 Manuel utilisateur

Amano
Amano MTX-15 Manuel utilisateur

FLOWBIRD
FLOWBIRD CWT Compact Touch Manuel utilisateur

Demco
Demco SP7 Manuel utilisateur