Critical Environment Technologies CET-RDM Manuel utilisateur

Operation Manual
www.critical-environment.com
RDM Remote Display Module
Rev. B | 2021.12

2 © 2021 All rights reserved. Data subject to change without notice.
RDM - Operation Manual Rev. B | 2021.12
TABLE OF CONTENTS
1 POLICIES .......................................................................................................4
1.1 Important Note .................................................................................................4
1.2 Warranty Policy.................................................................................................5
1.3 Service Policy....................................................................................................5
1.4 Copyrights and Registered Trademarks......................................................6
1.5 Disclaimer..........................................................................................................6
1.6 Revisions............................................................................................................7
2 INTRODUCTION .............................................................................................8
2.1 General Description .........................................................................................8
2.2 Key Features .....................................................................................................8
3 INSTRUMENT SPECIFICATIONS....................................................................9
3.1 Technical Specications.................................................................................9
3.2 Enclosure Dimensions ................................................................................. 11
4 INSTRUMENT FEATURES ............................................................................12
4.1 Exterior Enclosure......................................................................................... 12
4.2 Interior System Layout................................................................................. 13
5 INSTALLATION ............................................................................................14
5.1 General Safety Warnings ............................................................................. 14
5.2 Protection Against Electrical Risks............................................................ 15
5.3 Protection Against Mechanical Risks ....................................................... 15
5.4 Enclosure Mounting Components............................................................. 15
5.4.1 Enclosure Interior Base.................................................................. 16
5.4.2 Enclosure Bottom ........................................................................... 17
5.5 Wiring Power Connections.......................................................................... 17
5.6 Wiring the RDM to the FCS.......................................................................... 18

© 2021 All rights reserved. Data subject to change without notice. 3
Rev. B | 2021.12 RDM - Operation Manual
6 SYSTEM OPERATION & CONFIGURATION...................................................20
6.1 Navigating the Menu Structure .................................................................. 20
6.2 Accessing the Menu with Passcodes....................................................... 20
6.3 Power Up and Warm-up............................................................................... 21
6.4 Normal Display .............................................................................................. 21
6.5 Set LCD Display Contrast Level.................................................................. 23
6.6 Modbus® Settings........................................................................................ 24
6.6.1 Change Modbus® ID...................................................................... 24
6.6.2 Set Baud Rate .................................................................................. 25
6.7 Mask Lines ..................................................................................................... 26
6.8 Set Silence Duration ..................................................................................... 27
7 MAINTENANCE............................................................................................28
8 TROUBLE SHOOTING...................................................................................28

4 © 2021 All rights reserved. Data subject to change without notice.
RDM - Operation Manual Rev. B | 2021.12
1 POLICIES
1.1 Important Note
Read and understand this manual prior to using this instrument. Carefully read
the warranty policy, service policy, notices, disclaimers and revisions on the
following pages.
This product must be installed by a qualied electrician or factory trained
technician and according to instructions indicated in this manual.
This instrument has not been designed to be intrinsically safe. For your safety,
do not use it in classied hazardous areas (explosion-rated environments).
INSTRUMENT SERIAL NUMBER:
______________________________________________________
PURCHASE DATE:
______________________________________________________
PURCHASED FROM:
______________________________________________________

© 2021 All rights reserved. Data subject to change without notice. 5
Rev. B | 2021.12 RDM - Operation Manual
1.2 Warranty Policy
Critical Environment Technologies Canada Inc. warrants the products we
manufacture (excluding sensors, battery packs, batteries, pumps, and lters)
to be free from defects in materials and workmanship for a period of two years
from the date of purchase from our facility. Sensors are consumable items and
once they leave our factory, we cannot reuse or resell them. As such, all sensor
sales are nal. Should the sensor itself be faulty, there is a one-year pro-rated
warranty that would apply from the date of purchase from our facility.
The warranty status may be affected if the instrument has not been used and
maintained as per the instructions in the manual or has been abused, damaged,
or modied in any way. The product is only to be used for the purposes stated
in the manual. Critical Environment Technologies is not liable for auxiliary
interfaced equipment or consequential damage.
Prior to shipping equipment to CETCI, contact our oce for an RMA #. All
returned goods, regardless of reason, must be accompanied with an RMA
number. Please read our Warranty and Returns Policy and follow our RMA
Instructions and Form.
Due to ongoing research, development, and product testing, the manufacturer
reserves the right to change specications without notice. The information
contained herein is based on data considered accurate. However, no warranty is
expressed or implied regarding the accuracy of this data.
1.3 Service Policy
CETCI maintains an instrument service facility at the factory. Some CETCI
distributors / agents may also have repair facilities; however, CETCI assumes
no liability for service performed by anyone other than CETCI personnel.
Repairs are warranted for 90 days after date of shipment (sensors have
individual warranties). Should your instrument require non-warranty repair, you

6 © 2021 All rights reserved. Data subject to change without notice.
RDM - Operation Manual Rev. B | 2021.12
may contact the distributor from whom it was purchased, or you may contact
CETCI directly.
Prior to shipping equipment to CETCI, contact our oce for an RMA #. All
returned goods, regardless of reason, must be accompanied with an RMA
number. Please read our Warranty and Returns Policy and follow our RMA
Instructions and Form.
If the product is deemed repairable, for liability reasons, CETCI will perform all
necessary repairs to restore the instrument to its full operating condition.
1.4 Copyrights
This manual is subject to copyright protection; all rights are reserved. Under
international and domestic copyright laws, this manual may not be copied or
translated, in whole or in part, in any manner or format, without the written
permission of CETCI.
Modbus® is a registered trademark of Gould Inc. Corporation.
BACnet® is a registered trademark of American Society of Heating,
Refrigeration and Air Conditioning (ASHRAE).
1.5 Disclaimer
Under no circumstances will CETCI be liable for any claims, losses or damages
resulting from or arising out of the repair or modication of this equipment
by a party other than CETCI service technicians, or by operation or use of the
equipment other than in accordance with the printed instructions contained
within this manual or if the equipment has been improperly maintained or
subjected to neglect or accident. Any of the forgoing will void the warranty.
Under most local electrical codes, low voltage wires cannot be run within the
same conduit as line voltage wires. It is CETCI policy that all wiring of our

© 2021 All rights reserved. Data subject to change without notice. 7
Rev. B | 2021.12 RDM - Operation Manual
products meet this requirement and all wiring be within properly grounded
(earth or safety) conduit.
1.6 Revisions
This manual was written and published by CETCI. The manufacturer makes
no warranty or representation, expressed or implied, including any warranty of
merchantability or tness for purpose, with respect to this manual.
All information contained in this manual is believed to be true and accurate at
the time of printing. However, as part of its continuing efforts to improve its
products and their documentation, the manufacturer reserves the right to make
changes at any time without notice. In addition, due to improvements made to
our products, there may be information in this manual that does not exist in the
version of the product the user has. Should you detect any error or omission
in this manual, or should you want to inquire regarding upgrading the device’s
rmware, please contact CETCI at the following address:
Critical Environment Technologies Canada Inc.
Unit 145, 7391 Vantage Way, Delta, BC, V4G 1M3, Canada
Toll Free: +1.877.940.8741
Telephone: +1.604.940.8741
Email: [email protected]
Website: www.critical-environment.com
In no event will CETCI, its ocers or employees be liable for any direct, special,
incidental or consequential damages resulting from any defect in any manual,
even if advised of the possibility of such damages.

8 © 2021 All rights reserved. Data subject to change without notice.
RDM - Operation Manual Rev. B | 2021.12
2 INTRODUCTION
2.1 General Description
Thank you for purchasing our RDM Remote Display Module. The RDM Remote
Display is designed to connect to the FCS Flexible Control System to provide
convenient viewing of gas readings and system statuses in an alternate and
relevant location to the controller; such as a refrigeration application where
there are two different entrances to the chiller room.
The RDM will display much of the same information as the FCS, such
as gas level readings, channel status and faults.
2.2 Key Features
• 4-lines, 20 character LCD display and LED indicators for alarm STATUS 1,
2, 3 and Fault conditions
• Internal audible alarm
• Modbus®RS-485 RTU communication
• Output for remote strobe and/or horn connection
• Connection loss detection to ensure accurate information is displayed

© 2021 All rights reserved. Data subject to change without notice. 9
Rev. B | 2021.12 RDM - Operation Manual
3 INSTRUMENT SPECIFICATIONS
3.1 Technical Specications
MECHANICAL
Enclosure
ABS / Polycarbonate, rated UL94-5VA, designed
to meet IP54 standards. Copper coated interior to
reduce RF interference.
Weight 272 g (9.6 oz)
Size 127 mm x 127 mm x 71 mm (5.0 in x 5.0 in x 2.8 in)
ELECTRICAL
Power Requirement 0.5 W of power using the 24 VDC supplied by the
controller
Current Draw 20.8 mA
Wiring 4-wire shielded network wiring between the controller
and RDM
Communication:
Modbus® RTU over
RS-485
Baud rate: 19,200 (default)
Modbus® ID: 230 (default)
Modbus® Broadcast ID: 253 (default)
Data bits: 8
Start bits: 1
Stop bits: 1
Parity: none
Fuses Automatic resetting thermal

10 © 2021 All rights reserved. Data subject to change without notice.
RDM - Operation Manual Rev. B | 2021.12
USER INTERFACE
Display
4-line, 20 character LCD display and LED indicators
for “STATUS 1, 2 and 3” , “FAULT”
Congurable contrast (default is 20)
Indicator Status LED indicators for low, mid, high and fault
alarms
Menu Accessed using up, down and enter push buttons
INPUT/OUTPUT
Communication Receives Modbus® commands from the FCS and
duplicates the much of the display information
Outputs One drive output for a 24V, max 500 mA remote
strobe/horn
Audible Alarm Internal buzzer
ENVIRONMENTAL
Operating
Temperature -20°C to 40°C (-4°F to 104°F)
Operating Humidity 15 - 90% RH non-condensing
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur