4
10 The Footrest cannot
lift or recline.
①the terminal of foot rest actuator and wires are
poorly connected..
②the foot rest actuator fails.
③main PCB fails.
①Plug the terminal securely.
②replace the foot rest actuator.
③replace the main PCB.
11 No vibration by the
motors in the seat
pad.
①The vibrational motor fail
②The terminals and wires are poorly connected
or the wires fail.
③Main PCB fails.
①Replace the vibrational motor.
②Plug the terminal securely or
replace the wires.
③Replace the main PCB.
12 No kneading of the
Footrest
①The terminals are not touch well with PCB
or the wires are not connected.
②Main PCB fails。
①Plug the terminal securely or
replace the wires.
②Replace the main PCB。
14 No gas charging in
the seat-pad.
①The terminal of the snuffle valves
and wires are poorly connected.
②The snuffle valves fail.
③The inflator pump fails.
④Main PCB fails.
①Plug the terminal securely.
②Replace the snuffle valves.
③Replace the inflator pump.
④Replace main PCB.
15 No gas charging in
the Footrest
①The terminal of the snuffle valves and wires are
poorly connected.
②The snuffle valves fail.
③The inflator pump fails.
④Main PCB fails.
①Plug the terminal securely.
②Replace the snuffle valves.
③Replace the inflator pump.
④Replace main PCB.
二. Troubleshooting Process
Attention for repairing chair or replacing parts:
①Make sure the power is OFF before tearing down the wires, moving terminals or replacing parts.
②Semiconductors (such as IC and others) are very easy to be damaged by static, so when you touch
the PCB, please make sure your body is grounding (by wearing a girding static ring), or your hands
are touching with earthing grip (household electrical appliances putting to earth, such as fridges,
washers and …) to release all static of the body.